• 제목/요약/키워드: Resonance Type

검색결과 1,085건 처리시간 0.033초

Theoretical Studies on the Progonation Equilibria of Benzoyl Derivatives

  • 김왕기;김용빈;김창곤;이본수
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.395-400
    • /
    • 2001
  • The effects of ortho- (R = H and CH3) and Y-substituents (Y = OCH3, CH3H and CN), which are directly attached to the carbonyl carbon, on the protonation equilibria of the para-X-substituted benzoyl derivatives, 4-X -2, 6-di-R-C6H2-C(=O)-Y, are investigated theoretically using the B3LYP method with 6-31+G* basis set. Structurally, both of the (B) and (BH+ ) forms in the species with R = H are nearly coplanar regardless of the Y-substituents implying that the steric repulsion between Y-substituent and R = H is relatively small. In the species with R = CH3 , the tortional angle (Θ) between the carbonyl moiety and aryl ring varies from zero to near right angle depending on the degree of steric repulsion between Y and R = CH3 and the resonance demand. However the reaction energies, ΔG°, for the protonation processes are more favorable for R = CH3 than for R = H due to stronger electron donating effect of R = CH3 , although the species with R = CH3 are unfavorable sterically. On the other hand, the Hammett type plots are progressively better correlated with б+ than with б values on going from Y = OCH3 to Y = CN for both species with R = H and CH3 indicating that the degree of resonance delocalization between carbonyl moiety and X-substituent is increased for a more electron accepting Y-substituent. Nevertheless the effects of R = CH3 on the magnitude of Hammett type reaction constants ( б or б+ ) are not much different from those of R = H.

미세파상 패턴 ECM 에서 세포질 FAK 신호의 실시간 FRET 이미징 (Real-time FRET imaging of cytosolic FAK signal on microwavy patterned-extracellular matrix (ECM))

  • 서정수;장윤관;김태진
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권1호
    • /
    • pp.1-6
    • /
    • 2019
  • Human mesenchymal stem cells (hMSC) are multipotent stromal cells that have great potential to differentiate into a variety of cell types such as osteocytes, chondrocytes, and myocytes. Although there have been many studies on their clinical availability, little is known about how intracellular signals can be modulated by topographic features of the extracellular matrix (ECM). In this study, we investigated whether and how microwavy-patterned extracellular matrix (ECM) could affect the signaling activity of focal adhesion kinase (FAK), a key cellular adhesion protein. The fluorescence resonance energy transfer (FRET)-based FAK biosensor-transfected cells are incubated on microwavy-patterned surfaces and then platelet derived growth factor (PDGF) are treated to trigger FAK signals, followed by monitoring through live-cell FRET imaging in real time. As a result, we report that PDGF-induced FAK was highly activated in cells cultured on microwavy-patterned surface with L or M type, while inhibited by H type-patterned surface. In further studies, PDGF-induced FAK signals are regulated by functional support of actin filaments, microtubules, myosin-related proteins, suggesting that PDGF-induced FAK signals in hMSC upon microwavy surfaces are dependent on cytoskeleton (CSK)-actomyosin networks. Thus, our findings not only provide new insight on molecular mechanisms on how FAK signals can be regulated by distinct topographical cues of the ECM, but also may offer advantages in potential applications for regenerative medicine and tissue engineering.

유전체 이완 분광법의 원리 및 이를 이용한 전해액 미시구조 연구 (Basic theory of Dielectric Relaxation Spectroscopy and Studies of Electrolyte Structure)

  • 구본협;황순욱;이호춘
    • 전기화학회지
    • /
    • 제22권2호
    • /
    • pp.53-59
    • /
    • 2019
  • 전해질의 미시 구조분석을 위해서는 이온-이온 및 이온-용매 상호작용을 이해하는 것이 매우 중요하다. 이 총설은 유전체 이완 분광법(Dielectric relaxation spectroscopy)의 기본 원리와, 이를 이용한 전해질 구조 연구 사례를 소개하고자 한다. 유전체 이완 분광법은 임피던스법의 일종으로서, 수십 GHz 수준의 높은 주파수 영역에 걸쳐 전해질의 유전 특성을 측정한다. 이를 통해, 유전체 이완 분광법은 전해질 내 존재하는 다양한 극성 화학 종, 즉, 쌍극자 모멘트(Dipole moment)를 갖는 자유 용매(Free solvent) 및 이온쌍(Ion pair)의 종류와 농도에 대한 정보를 제공한다. 유전체 이완 분광법이 제공하는 정보는 기존 분석 기법(적외선 분광법(Infrared), 라만 분광법(Raman) 및 핵자기 공명 분광법(Nuclear magnetic resonance) 등)이 제공하는 정보들과 상호보완적 관계에 있으며, 이러한 종합적 분석을 통해 전해질 구조에 관한 깊은 이해가 가능하다.

골수술용 압전형 초음파 의료기기 개발을 위한 유한요소해석 및 이의 실험적 검증 (Finite Element Analysis for the Development of Bone Surgery Piezoelectric Ultrasonic Medical Device and its Experimental Verification)

  • 송태하;이중호;최종균;이희원
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권5호
    • /
    • pp.319-330
    • /
    • 2022
  • In this study, the optimal driving frequency was derived through finite element analysis (FEA) to optimize the developed piezoelectric ultrasonic medical devices(PUMD) for bone surgery. The core of the PUMD is the piezoelectric ceramic (PZT), which is a vibrator that generates vibration energy. The piezoelectric ceramic shows the maximum current value with respect to the input voltage at the resonance frequency, which generates the maximum mechanical vibration. In the past, various studies have been conducted related to the analysis of PUMD, but most of the research so far has been limited to free vibration analysis. However, in order to derive the accurate resonant frequency, the initial stress generated by bolt tightening in the bolt-clamped Langevin type transducer (BLT) must be considered. In this study, after designing a PUMD, the driving performance according to the bolt tightening value was analyzed through FEA, and this was experimentally verified. First, the resonance mode and frequency response were confirmed through modal and harmonic analysis at 20-40 kHz, which is known as the optimal driving frequency band of PUMD for bone surgery. In addition, the design of the PUMD was confirmed by checking the mechanical behavior of the tip and the piezoelectric ceramic at the resonant frequency. Consequentially, the characteristic evaluation was performed, and it was confirmed that the resonant frequency result derived through the FEA was reasonable. Through this study, we presented a more rational FEA method than before for BLT transducers. We expect that this will shorten the time and cost of developing a PUMD, and will enable the development of more stable and high-quality products.

점막하 구개열 환자 공명장애의 스펙트럼 특성 연구 (SPECTRAL CHARACTERISTICS OF RESONANCE DISORDERS IN SUBMUCOSAL TYPE CLEFT PALATE PATIENTS)

  • 김현철;임대호;백진아;신효근;김오환;김현기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권4호
    • /
    • pp.310-319
    • /
    • 2006
  • Submucosal type cleft palate is subdivision of the cleft palate. It is very difficult to find submucosal cleft, because when we exam submucosal type cleft palate patients, it seems to be normal. But in fact, there are abnormal union of palatal muscles of submucosal type cleft palate patients. Because of late detection, the treatment - for example, the operation or the speech therapy - for the submucosal type cleft palate patient usually becomes late. Some patients visited our hospital due to speech disorder nevertheless normal intraoral appearance. After precise intraoral examination, we found out submucosal cleft palate. We evaluated the speech before and after surgery of these patients. In this study, we want to find the objective characteristics of submucosal type cleft palate patients, comparing with the normal and the complete cleft palate patients. Experimental groups were 10 submucosal type cleft palate patients and 10 complete cleft palate patients who got the operation in our hospital. And, the controls were 10 normal person. The sentence patterns using in this study were simple 5 vowels. Using CSL program we evaluated the Formant, Bandwidth. We analized the spectral characteristics of speech signals of 3 groups, before and after the operation. In most cases, the formant scores were higher in experimental groups (complete cleft palate group and submucosal type cleft palate group) than controls. There were small differences when speeching /a/, /i/, /e/ between experimental groups and control groups, large differences when speeching /o/, /u/. After surgery the formant scores were decreased in experimental groups (complete cleft palate group and submucosal type cleft palate group). In bandwidth scores, there were no significant differences between experimental groups and controls.

Middle Cerebral Artery Duplication : Classification and Clinical Implications

  • Chang, Hoe-Young;Kim, Myoung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권2호
    • /
    • pp.102-106
    • /
    • 2011
  • Objective : Although there are several explanations for a duplicated middle cerebral artery (DMCA), its embryological origin is still an open question. We reviewed these anomalous vessels to postulate a theory of their different origins, sizes, and courses. Methods : A retrospective review of 1,250 cerebral angiographies, 1,452 computed tomography (CT)-angiographies, and 2,527 magnetic resonance (MR)-angiographies was performed to identify patients with DMCA. Results : Twenty-five patients had 25 DMCAs. Conventional angiography detected nine patients with DMCA (9/1250, 0.72%), MR-angiography detected seven patients with DMCA 0.28%), and CT-angiography detected nine patients with DMCA (9/1452, 0.62%). The DMCAs originated near the internal carotid artery terminal in eight patients (type A), and between the origin of the anterior choroidal artery and the terminal internal carotid artery in 17 patients (type B). The diameters of the eight type A DMCAs were the same or slightly smaller than those of the other branch of the DMCA. All type A DMCAs showed a course parallel to that of the other branch of the DMCA. The diameters of the 17 type B DMCAs were the same, slightly smaller, or very much smaller than that of the other branch of the DMCA. Nine type B DMCAs showed parallel courses, and the other eight curved toward the temporal lobe. Conclusion : The two branches of the type A DMCAs can be regarded as early bifurcations of the MCA. The branches of the type B DMCAs had parallel courses or a course that curved toward the temporal lobe. The type B DMCA can be regarded as direct bifurcations of the MCA trunk or the early ramification of the temporal branch of the MCA.

The effect of implant shape and bone preparation on primary stability

  • Moon, Sang-Hyun;Um, Heung-Sik;Lee, Jae-Kwan;Chang, Beom-Seok;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제40권5호
    • /
    • pp.239-243
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis. Methods: Sixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1 mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant. Results: Regardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P>0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P>0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P<0.05), whereas overpreparation significantly decreased the ISQ value (P<0.05). Conclusions: Within the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.

초음파 경도계의 측정정도에 관한 연구 (A Study on the Measuring Accuracy of Ultrasonic Hardness Tester)

  • 한응교;윤종학;김재열
    • 한국정밀공학회지
    • /
    • 제4권1호
    • /
    • pp.65-73
    • /
    • 1987
  • In recent days, the application of ultrasonics has been increased in the field of engineering and medicine. The ultrasonic hardness tester to apply the principle of contact compliance method is entirely different from hardness tester in the past and in the practical use, the more pre- cisive measurement is required because it has a slight change of hardness value due to the difference of resonance frequency. Therefore, in this study, as one type of applicative transducers which can detect the optimum pressure load, ring type load cell was used in the measurement of ultrasonic hardness. From experimental results, it was compared ultrasonic hardness testing method with the other hardness testing methods. Also, the measurement error of ultrasonic hardness tester could be measured within .+-. 0.5 HRC F.S. in the case of 3.0Kg pressure load.

  • PDF

Static and Dynamic Instability Characteristics of Thin Plate like Beam with Internal Flaw Subjected to In-plane Harmonic Load

  • R, Rahul.;Datta, P.K.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.19-29
    • /
    • 2013
  • This paper deals with the study of buckling, vibration, and parametric instability characteristics in a damaged cross-ply and angle-ply laminated plate like beam under in-plane harmonic loading, using the finite element approach. Damage is modelled using an anisotropic damage formulation, based on the concept of reduction in stiffness. The effect of damage on free vibration and buckling characteristics of a thin plate like beam has been studied. It has been observed that damage shows a strong orthogonality and in general deteriorates the static and dynamic characteristics. For the harmonic type of loading, analysis was carried out on a thin plate like beam by solving the governing differential equation which is of Mathieu-Hill type, using the method of multiple scales (MMS). The effects of damage and its location on dynamic stability characteristics have been presented. The results indicate that, compared to the undamaged plate like beam, heavily damaged beams show steeper deviations in simple and combination resonance characteristics.

Effect of Adjustable Antenna Substrate Thickness on Aperture-Coupled Microstrip Antenna

  • Somsongkul, T.;Lorpichian, A.;Janchitrapongvej, K.;Anantrasirichai, N.;Wakabayashi, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1664-1667
    • /
    • 2003
  • Aperture-coupled microstrip antenna is one type of microstrip antennas. This type of antenna has bandwidth wider than simple microstrip antenna. Herein, we use two substrates, that have the same dielectric constant 2.47 (PTFE-quartz) in which upper substrate is a rectangular patch. The microstrip patch is fed by a microstrip line which is printed on lower substrate, through an aperture or slot in the common ground plane of patch and microstrip feed. This antenna is analyzed by using Finite Difference Time Domain (FDTD) method the specific design frequency 10 GHz and match impedance is 50 ohms. The simulation results of its characteristics are input impedance, return loss, VSWR and radiation patterns respectively.

  • PDF