Study on the Electromagnetic Shielding of Accessory Device without Electromagnetic Shielding Technology in the Magnetic Resonance Room (자기공명검사실 내 전자기파 차단이 이루어지지 않은 부속장치의 차폐에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.431-436
    • /
    • 2021
  • In this study, a new shielding method was applied to an accessory device that produces electromagnetic waves in the magnetic resonance room to prevent the generation of artifact caused by electromagnetic waves. The research method applied a new shielding made of metal plating fiber to patient surveillance CCTVs without shielding technology, and obtained and evaluated noise map when the power was not cut off and when the new shielding technology was applied without shutting down the CCTV. As a result of the study, it was found that there was at least one group with significant differences. Type I and type III belonged to group 1 while type II belonged to group 2 in the Post-hoc analysis, which meant blocking power of the CCTV and the applying new shielding technology were in the same group. In conclusion, if electromagnetic waves are generated due to additional accessories in the scanning room, the shielding material proposed in this study should be applied which enables the electric state become similar to type I, not generating noise, thereby preventing the artifacts caused by electromagnetic waves.

The Stator Analysis and Design of Ring Type Ultrasonic Motor (링형 초음파모터의 고정자 해석 및 설계)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin;Kim, Hyun-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.10
    • /
    • pp.484-490
    • /
    • 2003
  • This paper describes with the stator analysis and design of a ring type ultrasonic motor. The design for piezoelectric ceramic and elastic body of stator were calculated by using the finite element method (FEM) that consider the resonance frequency, vibration mode and coupling efficiency. Namely, such results were acquired the calculation result of the piezoelectric ceramic thickness 0.5[mm], elastic body thickness 2.0[mm], resonance frequency 51.8[kHz], vibration mode 7 order and coupling efficient 12.5[%], the outer and inner diameter of vibrator 50[mm], 38[m]. On the basis of such result, the ring type ultrasonic motor was manufactured. Also for driving characteristics of ring type ultrasonic motor, 2-phase inverter was constructed. Then the propriety of this paper was established from comparision of the simulation and an experiment results of the ring type ultrasonic motor.

Magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment in patients with internal derangement (측두하악관절 내장 환자의 관절원판과 관절원판 후조직의 자기공명영상 신호강도)

  • Jeong Yeon-Hwa;Cho Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.93-99
    • /
    • 2001
  • Purpose: To analyze the possible association between magnetic resonance imaging signal intensity of temporomandibular joint disk and posterior attachment, and the type and extent of disk displacement, disk configuration, effusion and clinical signs in patients with internal derangement. Materials and Methods: Magnetic resonance images of the 132 temporomandibular joints of 66 patients with temporomandibular joint displacement were analyzed. The clinical findings were obtained by retrospective review of the patients' records. The type and extent of disk displacement, disk configuration and effusion were evaluated on the proton density MR images. The signal intensity from the anterior band, posterior band and posterior attachment were measured on MR images. The associations between the type and extent of disk displacement, disk configuration, effusion and clinical signs and the MR signal intensity of disk and posterior attachment were statistically analyzed by student's t-test. Results: Of 132 joints, 87 (65.9%) showed anterior disk displacement with reduction (ADR) and 45 (34.1%) showed anterior disk displacement without reduction (ADnR). The signals from posterior attachments were lower in joints with ADnR than those of ADR (p<0.05). The results showed statistically significant (p<0.05) association between the type and extent of disk displacement and disk configuration, and decreased signal intensity of posterior attachment. There were no statistical associations between pain, noise and limited mouth opening, and signal intensity of disk and posterior attachment. Conclusions: The average signal from posterior attachment was lower in joints with ADnR than that of ADR. The type and extent of disk displacement and disk configuration appeared to be correlated with the signal intensity from posterior attachment.

  • PDF

Sensitivity Analysis in the Estimation of Complex Elastic Modulus of Viscoelastic Materials by Transmissibility Measurements (전달율 측정에 의한 점탄성재료의 복소탄성계수 추출시의 민감도 분석)

  • 안태길;허진욱;김광준
    • Journal of KSNVE
    • /
    • v.2 no.2
    • /
    • pp.99-106
    • /
    • 1992
  • The complex Young's modulus of a viscoelastic material can be obtained as a function of frequency from the measurements of relative motion between the two ends of a bar-type specimen. Non-resonance method is usually used to obtain the complex Young's modulus over wide range of frequency including resonance points, while in resonance method information at resonance frequencies only is used. However, the complex Young's modulus obtained by the non-resonance method is often unreliable in the anti-resonance frequency regions because of the measurement noise problems. In this study, the effects of the random measurement errors on estimating the complex Young's modulus are studied in the aspect of sensitivity, and how to obtain the reliable frequency region for a given measurement error level is shown. The usable frequency regions in determining the complex Young's modulus are represented by a non-dimensional parameter formed with the wave length and specimen length.

  • PDF

Sensitivity simulation on isotopic fissile measurement using neutron resonances

  • Lee, YongDeok;Ahn, Seong-Kyu;Choi, Woo-Seok
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.637-643
    • /
    • 2022
  • Uranium and plutonium are required to be accounted in spent fuel head-end and major recovery area in pyro-process for safeguards purpose. The possibility of neutron resonance technique, as a nondestructive analysis, was simulated on isotopic fissile analysis for large scale process. Neutron resonance technique has advantage to distinguish uranium from plutonium directly in mixture. Simulation was performed on U235 and Pu239 assay in spent fuel and for scoping examination of assembly type. The resonance energies were determined for U235 and Pu239. The linearity in the neutron transmission was examined for the selected resonance energies. In addition, the limit for detection was examined by changing sample density, thickness and content for actual application. Several factors were proposed for neutron production and the moderated neutron source was simulated for effective and efficient transmission measurement. From the simulation results, neutron resonance technique is promising to analyze U235 and Pu239 for spent fuel assembly. An accurate fissile assay will contribute to an increased safeguards for the pyro-processing system and international credibility on the reuse of fissile materials in the fuel cycle.

FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System (소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서)

  • Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

Efficient Thermal Annealing for FBAR Devices

  • Song Hae-il;Mai Linh;Yoon Giwan
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.4
    • /
    • pp.167-171
    • /
    • 2005
  • In this paper, the resonance characteristics of SMR-type FBAR devices annealed by three different annealing methods are investigated and compared. The resonance characteristics could be effectively improved by the proposed efficient annealing method which optimizes the annealing conditions. It seems very useful for improving the performance of the SMR-type FBAR devices as a cost-effective way.

Configuration of Temporomandibular Joint Articular Disc in Magnetic Resonance Images and its Relationship to Treatment Response of Anterior Disc Displacement Without Reduction (자기공명영상사진 상에 나타난 측두하악관절원판의 형태 및 그에 따른 치료 효과의 분석)

  • Kwon, Jin-Hak;Kee, Woo-Cheon;Chol, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.1
    • /
    • pp.73-85
    • /
    • 2000
  • The purposes of the study were (1) to see if there are various types of disc configuration in normal temporomandibular joint and, if so, (2) to examine whether a specific type of disc configuration is susceptible to disc displacement, and (3) to see if a specific type of disc configuration and position is related to early relief of clinical symptoms from the anterior disc displacement without reduction to conservative treatment. From the magnetic resonance (MR) images taken for the patients with symptoms of temporomandibular disorders, 235 images as normal joint group, 255 images as anterior disc displacement with reduction group, and 249 images as anterior disc displacement without reduction group were selected, After the TMJ image was scanned and processed with Photoshop program, the disc configuration was determined, The incidence of various types of disc configuration was analyzed according to age, sex, diagnostic group, and the promptness of symptom relief. The disc position was also examined in relation to the promptness of symptom relief. The results were as follows : 1. In the normal joint group, biconcave type appeared most frequently and reversed, biplanar type in order, Posterior band enlarged and folded type didn't appear at all. On the other hand, in the anterior disc displacement without reduction group, folded type appeared most frequently and also posterior band enlarged type were found often. 2. There were statistically significant differences between sex and configuration of disc in the normal joint group and no statistically significant differences in the anterior disc displacement with reduction group and anterior disc displacement without reduction group, 3. There were no statistically significant differences between age and configuration of disc in the normal, anterior disc displacement with reduction group and anterior disc displacement without reduction group. 4. In anterior disc displacement without reduction group, rapid response was observed in biconcave and reversed type and delayed response was observed in folded type.

  • PDF

Development of Precision Moving Instrument by Using the Uni-morph type PZT Actuator (유니몰프 PZT 액츄에이터를 이용한 정밀 이송기구의 개발)

  • Kweon, Hyun-Kyu;Choi, Sung-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents a new precision moving instrument for the displacement and direction control using the uni-morph type PZT actuator. The instrument is composed of the two-body and a link. The body has the uni-morph type PZT actuator, which make the vibration. Movement of simple moving instrument is generally analyzed by the theory of center-of-gravity moment. However the analysis of the instrument in this paper is focused the resonance of instrument. Resonance of the body is originated a uni-morph type PZT actuator that is vibrated by voltage and frequency. The basic performances of one body instrument are analyzed by the FEM analysis. And experiments are also performed to confirm the linear movement of the instrument and direction control. it is proper a voltage control than a frequency control for the direction changing. And Moving velocity is 0.032m/s.

  • PDF

Design of a Variable Resonator for the Sacred Bell of the Great King Seongdeok (성덕대왕신종을 위한 가변형 명동의 설계)

  • Kim, Seock-Hyun;Jeong, Won-Tae;Kang, Yun-June
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.288-297
    • /
    • 2012
  • This study proposes a design model of the variable type resonator which corrects the temperature variance according to the season, in order to maximize the resonance effect in the Sacred bell of the Great King Seongdeok. In the bell, the 1st natural frequency (64 Hz) and the 2nd natural frequency (168 Hz) are the most important partial tones. Resonance conditions of the two components are determined for the internal acoustic cavity system, which consists of bell body cavity, gap and the resonator. Acoustic frequency response characteristics of the internal cavity are determined by the boundary element analysis using SYSNOISE. As an external factor, temperature variance according to the season largely influences the resonance condition and the length of the resonator should be controlled to maximize the resonance effect. As a measure, this study proposes a design model of the variable type resonator for the Sacred Bell of the Great King Seongdeok, which can control the length at the belfry according to the season.