• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.026 seconds

Relationship of the Shape of Subacromial Spur and Rotator Cuff Partial Thickness Tear

  • Kim, Young-Kyu;Jung, Kyu-Hak;Kang, Suk-Woong;Hong, Jin-Hun;Choi, Ki-Yong;Choi, Ji-Uk
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.139-145
    • /
    • 2019
  • Background: The present study was undertaken to evaluate the relationship between location of the rotator cuff tear and shape of the subacromial spur. Methods: Totally, 80 consecutive patients who underwent arthroscopic repair for partial thickness rotator cuff tear were enrolled for the study. Bigliani's type of the acromion, type of subacromial spur, and location of partial thickness tear of the rotator cuff were evaluated using plain X-ray and magnetic resonance imaging. We then compared the groups of no spur with spur, and heel with traction spur. Results: Of the 80 cases, 25 cases comprised the no spur group, and 55 cases comprised the spur group. There was a significant difference in type of tear (p=0.0004) between these two groups. Bursal side tears were significantly greater (odds ratio=6.000, p=0.0007) in the spur group. Subjects belonging to the spur group were further divided into heel (38 cases) and traction spur (17 cases). Comparing these two groups revealed significant differences only in the type of tear (p=0.0001). Furthermore, the heel spur had significantly greater bursal side tear (odds ratio=29.521, p=0.0005) as compared to traction spur. Conclusions: The heel spur is more associated to bursal side tear than the traction spur, whereas the traction spur associates greater to the articular side tear.

MR Imaging Findings of Cortical Dysplasia of the Brain: Correlation with Pathologic Grades and Subtypes (뇌피질 이형성증의 자기공명영상소견: 병리적 등급 및 유형과의 연관성에 대하여)

  • Bae Ju Kwon;Kee-Hyun Chang;Chun-Kee Chung;Moon Hee Han;Yoon La Choi;Je G. Chi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.47-55
    • /
    • 2003
  • Purpose : Cortical dysplasia is known to be of variety of MR imaging findings. We attempted to classify MR imaging findings of cortical dysplasia into several types and to correlate those with histopathologic grades and subtypes. Materials and Methods : Preoperative MR images of 97 patients with pathologically-proven cortical dysplasia were retrospectively reviewed with knowledge of the diagnosis and operative sites. The patients were divided into MR-positive and MR-negative groups based on the presence or absence of MR imaging abnormalities. In MR-positive group, MR imaging features were arbitrarily classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types) on the basis of size of the gyrus and adjacent CSF space, cortical thickness, signal intensity of the subcortical white matter, and blurring of the gray-white matter junction. The pathologic findings were also retrospectively reviewed without knowledge of MR imaging findings and divided into three grades (mild, moderate, and severe) and two subtypes (nonballoon-cell and balloon-cell). Pathologic grades and subtypes we re compared between MR-positive and MR-negative groups. Four MR types of the MR-positive group were correlated with the pathologic grades and subtypes. Results : MR-positive and MR-negative groups consisted of 39 (40%) and 58 (60%) patients, respectively. Of the MR-positive group, atrophic type was seen in 13 patients (33 %), cortical-band type in 9 (23%), inward-rounding type in 9 (23%), and nonspecific type in 8 (21%). There was no significant difference in the pathologic grades between MR-positive and MR-negative groups, although MR-positive group tended to have higher pathologic grades than MR-negative group did. Balloon-cell subtype was found significantly higher in MR-positive group than in MR-negative group (p<0 .05): 21% (8/39) versus 5% (3/58). The inward-rounding type corresponded to the pathologically severe grade and balloon-cell subtype in 78% (7/9) and 56% (5/9) of the patients, respectively, while the atrophic type to the mild grade and nonballoon-cell subtype in 77% (10/13) and 100% (13/13), respectively. Conclusion : A variety of MR imaging abnormalities were found in 40% of the patients with cortical dysplasia and those were classified into four types (atrophic, cortical-band, inward-rounding, and nonspecific types), of which the inward-rounding type correlated well with the pathologically severe grade and balloon-cell subtype, whereas the atrophic type with the mild grade and nonballoon-cell subtype.

  • PDF

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Fabrication of RF Inductor Using FeTaN Patterned Soft Magnetic Films (Patterned FeTaN 연자성 박막을 이용한 RF inductor의 제조)

  • Bae, Seok;Kim, Choong-Sik;Ryu, Sung-Ryong;Nam, Seoung-Eui;Kim, Hyoung-June;Song, Jae-Sung;Yamaguchi, Masahiro
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.239-244
    • /
    • 2001
  • Recently, RF inductor having researched by many workers, we fabricated and investigated properties of RF inductors. In order to improve the Q-factor (Quality), we try to apply the patterned Fe$_{78.81}$Ta$_{8.47}$N$_{12.71}$ soft magnetic thin film of 5000 which shows magnetic anisotropy of 30 Oe. Thus, patterned magnetic film was artificially increased magnetic anisotropy lead to increasing of ferro-magnetic resonance frequency up to GHz band. Coil as part of inductor was fabricated by lift off process. The dimension of RF inductor was designed 47un, rectangular shape, and measured properties. In the case of Ti/Ag air core type inductor shows Q of 9, inductance of 8.4 nH at 2 GHz. Magnetic film employed inductor shows inductance of 9 nH and FMR resonance frequency was 700 MHz.

  • PDF

Comparable Electron Capture Efficiencies for Various Protonated Sites on the 3rd Generation Poly(Propylene Imine) Dendrimer Ions: Applications by SORI-CAD and Electron Capture Dissociation Mass Spectrometry (ECD MS)

  • Han, Sang-Yun;Lee, Sun-Young;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.740-746
    • /
    • 2005
  • In this article, we report the tandem mass spectrometry investigations for the electron capture efficiencies of the protons belonging to the different locations (generations) in a poly(propylene imine) dendrimer with three layers of a repeat unit (named as the third generation dendrimer). The employed tandem mass spectrometry methods include SORI-CAD (sustained off-resonance irradiation collisional activation dissociation) and ECD(electron capture dissociation) mass spectrometry. We obtained SORI-CAD spectra for the dendrimer ions in the different charge states, ranging from 2+ to 4+. The analysis of fragmentation sites provides the information as to where the protons are distributed among various generations of the dendrimer. Based upon this, a new strategy to study the electron capture efficiencies of the protons is utilized to examine a new type of triplycharged ions by SORI-CAD, i.e., the 3+ ions generated from the charge reduction of the native 4+ ions by ECD: (M+4H)$^{4+}\;+\;e^-\;{\rightarrow}$ (M+4H)$^{3+\bullet}$ ${\rightarrow}\;({H^{\bullet}}_{ejected}$) + (M+3H)$^{3+}\;\rightarrow$ CAD. Interestingly, comparison of these four SORICAD spectra indicates that the proton distribution in the charge-reduced 3+ ions is very close to that in the native 4+ ions. It further suggests that in this synthetic polymer ($\sim$1.7 kDa) with an artificial architecture, the electron capture efficiencies of the protons are actually insensitive to where they are located in the molecule. This is somewhat contradictory to common expectations that the protons in the inner generations may not be well exposed to the incoming electron irradiation as much as the outer ones are, thus may be less efficient for electron capture. This finding may carry some implications for the case of medium sized peptide ions with similar masses, which are known to show no obvious site-specific fragmentations in ECD MS.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Structural characterization of calmodulin like domain of ryanodine receptor type 1

  • Song, Yonghyun;Kang, Sunmi;Park, Sunghyouk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • Ryanodine receptor (RyR) is one of the two major $Ca^{2+}$ channels in membranes of intracellular $Ca^{2+}$ stores and is found in sarcoplasmic reticulum (SR), endoplasmic reticulum (ER). RyR1 is also the major calmodulin-binding protein of sarcoplasmic reticulum membranes. Residues 4064-4210 in the RyR1 polypeptide chain has similar primary sequence with calmodulin (CaM) and was designated as CaM-like domain (CaMLD). When expressed as a recombinant peptide, CaMLD showed several CaM-like properties in previous studies. Still, previous studies of CaMLD were focused on protein-protein interactions rather than its own properties. Here, we studied the expression of CaMLD and its sub-domains corresponding to each lobe of CaM in Escherichia coli. CaMLD could be obtained only as inclusion body, and it was refolded using urea solubilization followed by dialysis. Using spectroscopic approaches, such as NMR, circular dichroism, and gel filtration experiment, we found that the refolded CaMLD exists as nonspecific aggregate, even though it has alpha helical secondary structure. In comparison, the first half of CaMLD (R4061-4141) could be obtained as natively soluble protein with thioredoxin fusion. After the removal of the fusion tag, it exhibited folded and helical properties as shown by NMR and circular dichroism experiments. Its oligomeric status was different from CaMLD, existing as dimeric form in solution. However, the second half of the protein could not be obtained as soluble protein regardless of fusion tag. Based on these results, we believe that CaMLD, although similar to CaM in sequence, has quite different physicochemical properties and that the second half of the protein renders it the aggregative properties.

A Study on the Status of Installation and Utilization of Magnetic Resonance Imaging in Korea (자기공명영상진단기(磁氣共鳴影像診斷機)(MRI)의 보유현황(保有現況) 및 이용실태(利用實態)에 관한 조사연구(調査硏究) -부산시내(釜山市內) 3개(個) 병원(病院)을 중심(中心)으로-)

  • Kim, Kyoung-Bae;Lee, Man-Jae
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.37-47
    • /
    • 1992
  • Magnetic Resonance Imaging(MRI) is one of the most expensive and sophisticated diagnostic tool and has been hailed as the most exciting event in medical imaging "since the introduction of X-rays", but a major disadvantage, high cost, is coming into focus especially in our country. To determine the status of distribution of MR imagers in Korea and to serve as a basic material for an efficient utilization of this Imaging machine, a retrospective survey of nationwide and regional(3 hospitals in Pusan) installations was performed. The results were as follows : 1. As of April 30, 1991, a total of 33 MRI units(24 for superconducting, 6 for permanent and 3 for resistive units) were set up and operated. 91% of the units were distributed in big cities with no one installation in 7 provinces among 12 provinces in our country. 85% of the units were imported. 2. Although 42.4% of the units were operated in Seoul, Taejeon had the best condition for the distribution of this imaging machine per population, hospital, and bed in Korea. 3. In Pusan : a) 5 units were operated with all superconducting magnet and medium magnetic field in type of machine. b) 80.1 % of the examinations were central nervous system(CNS). c) MRI examination occupied 1.4% of all radiographic examinations and the patients referred from other hospitals were composed of 23.4%% of all patients. 4. The average days under operating of MRI unit a week in Puasn were higher(5.5) than that of Seoul(4.5), but the average number of examinations and hours a week and a day, respectively(33, 8.4), was less than that of Seoul(57, 12.9). 5. The patients with positive MRI findings in a hospital(B) in Pusan was 74.5% on an average.

  • PDF

Design of Electromagnetically Driven Micro Scanning Mirror for Laser Animation System (레이저 디스플레이를 위한 전자력 구동 스캐닝 미러의 설계)

  • Lee, Kyoung-Gun;Jang, Yun-Ho;Yoo, Byung-Wook;Jin, Joo-Young;Lim, Yong-Geun;Kim, Yong-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.578-585
    • /
    • 2009
  • In this paper, we present the design of an electromagnetic scanning mirror with torsional springs. The scanning mirror consisting of torsional springs and electromagnetic coils was designed for the applications of laser animation systems. We analyzed and optimized three types of torsional springs, namely, straight beam springs (SBS), classic serpentine springs (CSS), and rotated serpentine springs (RSS). The torsional springs were analyzed in terms of electrical resistance, fabrication error tolerance, and resonance mode separation of each type using analytical formula or numerical analysis. The RSS has advantages over the others as follows: 1) A low resistance of conductors, 2) wide resonance mode separation, 3) strong fabrication error tolerance, 4) a small footprint. The double-layer coils were chosen instead of single-layer coils with respect to electromagnetic forces. It resulted in lower power consumption. The geometry of the scanning mirror was optimized by calculations; RSS turn was 12 and the width of double-layer coil was $100{\mu}m$, respectively. When the static rotational angle is 5 degrees, the power consumption of the mirror plate was calculated to be 9.35 mW since the resistance of the coil part and a current is $122{\Omega}$ and 8.75 mA, respectively. The power consumption of full device including the mirror plate and torsional springs was calculated to be 9.63 mW.

Microvascular Decompression for Primary Trigeminal Neuralgia : Short-Term Follow-Up Results and Prognostic Factors

  • Tucer, Bulent;Ekici, Mehmet Ali;Demirel, Serkan;Basarslan, Seyit Kagan;Koc, Rahmi Kemal;Guclu, Bulent
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.1
    • /
    • pp.42-47
    • /
    • 2012
  • Objective : The aim of this prospective study was to demonstrate the influence of some factors on the prognosis of microvascular decompression in 37 patients with trigeminal neuralgia. Methods : The results of microvascular decompression (MVD) in 37 patients with trigeminal neuralgia were evaluated at 6 months after surgery and were compared with clinical and operative findings. Results : The sex of the patient, the patient's age at surgery, the side of the pain, and the duration of symptoms before surgery did not play any significant roles in prognosis. Also, the visual analogue scale (VAS) of the patient, the duration of each pain attack, and the frequency of pain over 24 hours did not play any significant roles in prognosis. In addition, intraoperative detection of the type of conflicting vessel, the degree of severity of conflict, and the location of the conflict around the circumference of the root did not play any roles in prognosis. The only factors affecting the prognosis in MVD surgery were intraoperative detection of the site of the conflict along the root and neuroradiological compression signs on preoperative magnetic resonance imaging (MRI)/magnetic resonance angiography (MRA). Conclusion : These findings demonstrated that if neurovascular compression is seen on preoperative MRI/MRA and/or compression is found intraoperative at the root entry zone, then the patient will most likely benefit from MVD surgery.