Classification system for partial distal biceps tendon tears: a descriptive 3-Tesla magnetic resonance imaging study of tear morphology

  • Alex B Boyle;Simon BM MacLean
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.366-372
    • /
    • 2023
  • Background: There is minimal literature on the morphology of partial distal biceps tendon (DBT) tears. We sought to investigate tear morphology by retrospectively reviewing 3-Tesla magnetic resonance imaging (3T MRI) scans of elbows with partial DBT tears and to propose a basic classification system. Methods: 3T MRI scans of elbows with partial DBT tears were retrospectively reviewed by two experienced observers. Basic demographic data were collected. Tear morphology was recorded including type, presence of retraction (>5 mm), and presence of discrete long-head and short-head tendons at the DBT insertion. Results: For analysis, 44 3T MRI scans of 44 elbows with partial DBT tears were included. There were 9 isolated long-head tears (20%), 13 isolated short-head tears (30%), 2 complete long-head tears with a partial short-head tear (5%), 5 complete short-head tears with a partial long-head tear (11%), and 15 peel-off tears (34%). Retraction was seen in 5 or 44 partial tears (11%), and 13 of the 44 DBTs were bifid tendons at the insertion (30%). Conclusions: Partial DBT tears can be classified into five sub-types: long-head isolated tears, short-head isolated tears, complete long-head tears with partial short-head involvement, complete short-head tears with partial long-head involvement, and peel-off tears. Classification of tears may have implications for operative and non-operative management. Level of evidence: III.

The Usefulness of Diffusion-weighted MR Imaging for Differentiation between Degenerative Spines and Infectious Spondylitis (퇴행성 척추와 감염성 척추염의 감별에 있어서 확산강조영상의 유용성)

  • 박원규;변우목;최준혁
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.152-157
    • /
    • 2002
  • Purpose : The differential diagnosis between Modic type I degenerative spine and infectious spondylitis sometimes is difficult, because the affected bone marrows in both disease show similar signal intensity on conventional MR imaging. We evaluate the usefulness of diffusion-wighted MR imaging for differential diagnosis between Modic type I degenerative spine and infectious spondylitis. Materials and methods : The spin-echo and diffusion-weighted MR images of eight patients with Modic type I degenerative spines and 14 patients with infectious spondylitis diagnosed by clinical findings or CT-guided biopsies we re analyzed. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the vertebral bone marrow on conventional spin-echo and diffusion-weighted MR imaging were compared between degenerative spine and infectious spondylitis. Results : On T1-weighte d images, the affeted bone marrow in both disease showed hypointense signals. On T 2-weighted images, all of type I degenerative spine and 11 of infectious spondylitis showed hyperintensity, and three of infectious spondylitis showed heterogeneo us mixed signal intensity. On diffusion-weighted MR images, all of type I degenerative spine were hypointense with peripheral high signal intensity to normal vertebral body, but infectious spondylitis was hyperintense (n = 11) and hypointense (n=3). Conclusion : Diffusion-weighted MR imaging is useful to differentiate Modic type I degenerative spine from infectious spondylitis. On diffusion-weighted images, the high singal intensity of bone marrow suggests infectious spondylitis, whereas the low signal intensity of bone marrow with peripheral focal high signal intensity suggests type I degenerative spine.

  • PDF

Statistical Study of Conservative Treated Herniated Intervertebral Lumbar Disc (요추 추간판탈출증 환자의 보존적 치료에 대한 통계적 연구)

  • Kim, Su-Jang;Kim, Yong;Kim, Sung-Yong;Lee, Jeong-Hun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.3 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • Objectives : The object is to study a clinical effect regarding the conservative treatment of the patient who was diagnosed as the herniated Intervertebral lumbar disc(HIVD) and hospitalized in the oriental medical hospital and clinical study about the type of the HIVD. Methods. The clinical studies were done on 65 cases (hospitalized in Dept. of Oriental Rehabilitation Medicine, jaseng on oriental medical hospital from June 2001 to May 2002) who complained of low back pain or sciatica and diagnosed as HIVD on CT(computerized tomography) or MRI(magnetic resonance imaging). They were given both oriental conservative treatment and exercise during the hospitalization period. We investigated and observed 20 items about sex, age, weight, height, occupation, smoking. obesity, duration of disease, clinical symptom and treatment duration in basis of medical recording which was drawn up at patient hospitalization. We classified HIVD with 4 types(Bulging. Protruded. Extruded, Sequestered) and decided the case which simultaneously had 2 overs with Mixed type. The treatment evaluation standard was classified with 4 branches; Excellent. Good, Fair and Poor. Results & Conclusions : The treatment result of over 'fair' is bulging type 85%, protruded type 92.7%, extruded type 100% and the mixed type was 85.1 %. The effect was good in order of bulging, mixed, protruded and extruded type. It appeared most plentifully with 30 people in L4-5 and L5-S 1 disc herniation type.

  • PDF

Relation between shape of the articular eminence and disc displacement in the temporomandibular joint (측두하악관절에서 관절융기 형태와 관절원판 변위와의 연관성 연구)

  • Lee Heung-Ki;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.145-151
    • /
    • 2001
  • Purpose : To investigate the hypothesis that the morphology of the articular eminence of the temporomandibular joint is a predisposing factor for disc displacement. Materials and Methods: MR images of 126 temporomandibular joints in 94 patients were analyzed to assess for morphology of the articular eminence and disc displacement. The displaced disc was further categorized as disc displacement with reduction (DDWR) and disc displacement without reduction (DDWOR). The morphology of the articular eminence was classified into four types; box, sigmoid, flattened, and deformed. The relationship between the four types of shape of the articular eminence and the two types of disc position was assessed. Results: In the DDWR and DDWOR groups, the morphology of articular eminence were a box type in 40.5%, a sigmoid type in 30.2%, a flattened type in 24.6%, and a deformed type in 4.7%. The box type of the articular eminence were 34.3% in the DDWR group and 42.9% in the DDWOR group. The sigmoid type of the articular eminence were 34.3% in the DDWR group and 28.6% in the DDWOR group. The flattened type of the articular eminence were 28.6% in the DDWR group and 23.1 % in the DDWOR group. The deformed type of articular eminence were 2.9% in the DDWR group and 5.5% in the DDWOR group. Conclusion: Disc displacement is more likely to be found in the temporomandibular joints with a box-shaped articular eminence. It can be considered that shape of the articular eminence is related to the development of disc displacement.

  • PDF

A Study on The transducer of acoustic sensor to be Single-mode FBG using Hopper Type WDM be in the Making (Hopper type WDM을 이용한 단일모드 FBG(Fiber Bragg Grating)음향센서 트랜스듀서 개발연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.256-263
    • /
    • 2014
  • We have designed and made three kinds of FBG(Fiber Bragg Grating) Acoustic Transducer using Hopper type WDM on the use of recently developed FBG in Korea. The newly designed three kinds of FBG Acoustic Transducer using Hopper type WDM have an excellent merit of practical use with simple structure of sensors arm as well as the merit with existing fiber sensors. It was possible to detect sound waves in the range of 10 Hz to 18 kHz through the newly designed three kinds of FBG Acoustic Transducer and also, possible to detect its signal within the maximum range of 8.6 m by the use of most suitable resonance condition of the transducer. Especially, we can expect the utilization of low-frequency signal detection instead of existing acoustic sensor in the environment of electric noise and inferior condition. Furthermore, they can be developed as the high-sensibility and multi-point signal detection system through the sensor array system.

FDTD 방법을 이용한 3T MRI용 RF 코일의 해석

  • 이종오;박준서;명노훈;박부식;김용권;정성택
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.976-983
    • /
    • 2000
  • In this paper, Bridcage type RF coils used widely as RF coils for MRI and its applicable type, spiral type RF coil are analyzed and designed using FDTD method. In low tesla (IT, 1.5T) MRI system, several tools have been used for the analysis and design of the RF coils for MRI. This includes, so-called, LC equivalent circuit method for predicting the resonance frequency of the coil and the Biot-Savart law to determine the field distribution within the coil. Both of the circuit analysis and Biot-Savart law are low frequency techniques. Therefore, at high frequency applications, the circuit model approximation breaks down because the coil geometry is a significant fraction of the wavelength. In this paper, we analyzed and designed RF coils for 3T MRI using FDTD method. This method is a full wave analysis and very accurate at low and high frequencies. Also, this RF coils are actually fabricated and FDTD models of RF coils for MRI are proven.

  • PDF

Feasibility of Gamma Knife Radiosurgery for Brain Arteriovenous Malformations According to Nidus Type

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.431-441
    • /
    • 2024
  • Objective : Gamma Knife radiosurgery (GKRS) is an effective and noninvasive treatment for high-risk arteriovenous malformations (AVMs). Since differences in GKRS outcomes by nidus type are unknown, this study evaluated GKRS feasibility and safety in patients with brain AVMs. Methods : This single-center retrospective study included patients with AVM who underwent GKRS between 2008 and 2021. Patients were divided into compact- and diffuse-type groups according to nidus characteristics. We excluded patients who performed GKRS and did not follow-up evaluation with magnetic resonance imaging or digital subtraction angiography within 36 months from the study. We used univariate and multivariate analyses to characterize associations of nidus type with obliteration rate and GKRS-related complications. Results : We enrolled 154 patients (mean age, 32.14±17.17 years; mean post-GKRS follow-up, 52.10±33.67 months) of whom 131 (85.1%) had compact- and 23 (14.9%) diffuse-type nidus AVMs. Of all AVMs, 89 (57.8%) were unruptured, and 65 (42.2%) had ruptured. The mean Spetzler-Martin AVM grades were 2.03±0.95 and 3.39±1.23 for the compact- and diffuse-type groups, respectively (p<0.001). During the follow-up period, AVM-related hemorrhages occurred in four individuals (2.6%), three of whom had compact nidi. Substantial radiation-induced changes and cyst formation were observed in 21 (13.6%) and one patient (0.6%), respectively. The AVM complete obliteration rate was 46.1% across both groups. Post-GKRS complication and complete obliteration rates were not significantly different between nidus types. For diffuse-type nidus AVMs, larger AVM size and volume (p<0.001), lower radiation dose (p<0.001), eloquent area location (p=0.015), and higher Spetzler-Martin grade (p<0.001) were observed. Conclusion : GKRS is a safe and feasible treatment for brain AVMs characterized by both diffuse- and compact-type nidi.

GHz Bandwidth Characteristics of Rectangular Spiral type Thin Film Inductors (사각 나선형 박막 인덕터의 GHz 대역 특성)

  • Kim, J.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.52-57
    • /
    • 2004
  • In this research, characteristics of air core rectangular spiral type inductors of ㎓ band are numerical analyzed. The basic structure of inductors is a rectangular spiral having 390${\mu}{\textrm}{m}$${\times}$390${\mu}{\textrm}{m}$ size, 5.5 turns, line width of 10 ${\mu}{\textrm}{m}$ and line space of 10 ${\mu}{\textrm}{m}$. Frequency characteristics were simulated up to 10 ㎓. The substrate was modeled as Si, Sapphire, glass and GaAs and the conductor as Cu. The thickness of the conductor was fixed at 2. The number of turns was n.5 to make the input and output terminals to be on the opposite sides. The initial inductance of the basic inductor structure was 13.0 nH, maximum inductance 60.0 nH and resonance frequency 4.25 ㎓. As the dielectric constant of the substrate was increased, the initial inductance varied only slightly, but the resonance frequency decreased considerably. As the number of turns was varied from 1.5 to 9.5, the initial inductance was increased linearly from 2.9 nH to 15.9 nH and, then, saturated at 16.9 nH. The Q factor increased only slightly. The line width and line space of inductors were varied from 5 ${\mu}{\textrm}{m}$ to 20 ${\mu}{\textrm}{m}$, which resulted in the decrease of the initial and maximum inductances. But the resonance frequency was increased. Q factor displayed an increase and a decrease, respectively, when the line width and line space were increased.

Craniopharyngiomas : Radiological Differentiation of Two Types

  • Lee, In Ho;Zan, Elcin;Bell, W. Robert;Burger, Peter C.;Sung, Heejong;Yousem, David M.
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.466-470
    • /
    • 2016
  • Objective : To determine imaging features that may separate adamantinomatous and papillary variants of craniopharyngiomas given that tumors with adamantinomatous signature features are associated with higher recurrence rates, morbidity, and mortality. We specifically reviewed calcification on CT, T1 bright signal intensity, and cystic change on T2 weighted images for differentiating these two types. Methods : We retrospectively reviewed the MRI and CT studies in 38 consecutive patients with pathologically proven craniopharyngiomas between January 2004 and February 2014 for the presence of calcification on CT scans, bright signal intensity on T1 weighted images, and cystic change on T2 weighted images. Results : Of the 38 craniopharyngiomas, 30 were adamantinomatous type and 8 were papillary type. On CT scans, calcification was present in 25 of 38 tumors. All calcified tumors were adamantinomatous type. Twenty four of 38 tumors had bright signal intensity on T1 weighted images. Of these 24 tumors, 22 (91.7%) were adamantinomatous and 2 were papillary type. Cystic change on T2 weighted images was noted in 37 of 38 tumors; only 1 tumor with papillary type did not show cystic change. Conclusion : T1 bright signal intensity and calcification on CT scans uniformly favor the adamantinomatous type over papillary type of craniopharyngioma in children. However, these findings are more variable in adults where calcification and T1 bright signal intensity occur in 70.6% and 58.8% respectively of adult adamantinomatous types of craniopharyngiomas.

Study of Motion Effects in Cartesian and Spiral Parallel MRI Using Computer Simulation (컴퓨터 시뮬레이션을 이용한 직각좌표 및 나선주사 방식의 병렬 자기공명 영상에서 움직임 효과 연구)

  • Park, Sue-Kyeong;Ahn, Chang-Beom;Sim, Dong-Gyu;Park, Ho-Chong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Purpose : Motion effects in parallel magnetic resonance imaging (MRI) are investigated. Parallel MRI is known to be robust to motion due to its reduced acquisition time. However, if there are some involuntary motions such as heart or respiratory motions involved during the acquisition of the parallel MRI, motion artifacts would be even worse than those in conventional (non-parallel) MRI. In this paper, we defined several types of motions, and their effects in parallel MRI are investigated in comparisons with conventional MRI. Materials and Methods : In order to investigate motion effects in parallel MRI, 5 types of motions are considered. Type-1 and 2 are periodic motions with different amplitudes and periods. Type-3 and 4 are segment-based linear motions, where they are stationary during the segment. Type-5 is a uniform random motion. For the simulation, Cartesian and spiral grid based parallel and non-parallel (conventional) MRI are used. Results : Based on the motions defined, moving artifacts in the parallel and non-parallel MRI are investigated. From the simulation, non-parallel MRI shows smaller root mean square error (RMSE) values than the parallel MRI for the periodic (type-1 and 2) motions. Parallel MRI shows less motion artifacts for linear(type-3 and 4) motions where motions are reduced with shorter acquisition time. Similar motion artifacts are observed for the random motion (type-5). Conclusion : In this paper, we simulate the motion effects in parallel MRI. Parallel MRI is effective in the reduction of motion artifacts when motion is reduced by the shorter acquisition time. However, conventional MRI shows better image quality than the parallel MRI when fast periodic motions are involved.

  • PDF