• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.028 seconds

A Study on Basic Characteristics of a Coplanar-type Transmission Line Employing Periodic Structure on Si RFIC (Si RFIC상에서 주기적 구조를 이용한 코프레너형 전송선로의 기본특성연구)

  • Joh, Han-Nah;Park, Young-Bae;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.964-973
    • /
    • 2008
  • In this study, a short-wavelength coplanar-type transmission line employing periodic ground structure (PGS) was developed for application to miniaturized on-chip passive component on Si Radio Frequency Integrated Circuit (RFIC). The transmission line employing PGS showed shorter wavelength and lower characteristic impedance than conventional coplanar-type transmission line. The wavelength of the transmission line employing PGS structure was 57 % of the conventional coplanar-type transmission line on Si substrate. Using the theoretical analysis. basic characteristics of the transmission line employing PGS (e.g., bandwidth. loss, impedance, and resonance characteristics) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on silicon RFIC. According to the results. the bandwidth of the transmission line employing PGS was more than 895 GHz as long as T is less than 20${\mu}m$, and the resonance characteristic was observed in 1239 GHz, which indicates that the PPGM structure is a promising candidate for application to a development of miniaturized on-chip passive components on Si RFIC.

Metabolite analysis in the type 1 diabetic mouse model

  • Park, Sung Jean
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.25 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Type 1 diabetes mellitus (T1DM) is caused by insufficient production of insulin, which is involved in carbohydrate metabolism. Type 2 diabetes mellitus (T2DM) has insulin resistance in which cells do not respond adequately to insulin. The purpose of this study was to estimate the characteristics of type 1 diabetes using streptozotocin-treated mice (STZ-mouse). The sera samples were collected from the models of hyperglycemic mouse and healthy mouse. Based on the pair-wise comparison, five metabolites were found to be noticeable: glucose, malonic acid, 3-hyroxybutyrate, methanol, and tryptophan. It was very natural glucose was upregulated in STZ-mouse. 3-hyroxybutyrate was also increased in the model. However, malonic acid, tryptophan, and methanol was downregulated in STZ-mouse. Several metabolites acetoacetate, acetone, alanine, arginine, asparagine, histidine, lysine, malate, methionine, ornithine, proline, propylene glycol, threonine, tyrosine, and urea tended to be varied in STZ-mouse while the statistical significance was not stratified for the variation. The multivariate model of PCA clearly showed the group separation between healthy control and STZ-mouse. The most significant metabolites that contributed the group separation included glucose, citrate, ascorbate, and lactate. Lactate did not show the statistical significance of change in t-test while it tends to down-regulated both in DNP and Diabetes.

A Study on the Absorption Performance of a Perforated Panel type of Resonator (다공패널형 공명기의 흡음성능에 관한 연구)

  • Song, Hwayoung;Yang, Yoonsang;Lee, Donghoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.

Magnetic resonance imaging analysis of screw in-type lateral anchor pull-out in large to massive rotator cuff repair in patients older than 60 years

  • Lee, Sang-Yoon;Noh, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.15-21
    • /
    • 2022
  • Background: This study was performed to identify the incidence of screw in-type lateral anchor pull-out in patients older than 60 years who underwent rotator cuff repair for large to massive rotator cuff tear (RCT). Methods: We reviewed 25 patients over 60 who were diagnosed with large to massive RCT and underwent arthroscopic rotator cuff repair in our hospital from March 2017 to February 2021. Preoperative tear size (anterior to posterior, medial to lateral) was measured via preoperative magnetic resonance imaging (MRI). All 25 patients underwent MRI scanning on postoperative day 1 and at 3 months after surgery. The change of anchor position was measured in axial views on MRI images postoperative day 1 and 3 months after surgery. And it was statistically compared according to bone mineral density (BMD), sex, and number of lateral anchors. Results: Two MRIs (postoperative day 1 and 3 months) in 25 patients were compared. Anchor pull-out occurred in six patients during 3 months (6.7%), and the mean pull-out length difference was 1.56 mm (range, 0.16-2.58 mm). There was no significant difference in the number of pull-out anchors, degree of pull-out difference by comparing BMD (A, BMD≤-2.5; B, BMD>-2.5), sex, or number of anchors used in each surgery (C, two anchors; D, three anchors) (p>0.05). Conclusions: Pull-out of screw in-type anchors was rarely observed and the mean pull-out length difference was negligibly small in our study. The screw in-type lateral anchor seems to be a decent option without concern of anchor pull-out even in elderly patients.

Differential Subsampling with Cartesian Ordering Contrast-Enhanced Magnetic Resonance Angiography for the Preoperative Assessment of Anterolateral Thigh Flap

  • Yunfeng Shen;Xiucun Li;Chao Zhang;Hai Zhong;Weiqiang Dou
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.803-810
    • /
    • 2022
  • Objective: To investigate the clinical application of differential subsampling with Cartesian ordering (DISCO) contrast-enhanced (CE) magnetic resonance angiography for anterolateral thigh (ALT) flap transplantation, using operative findings as a reference. Materials and Methods: Thirty patients (21 males and nine females; mean age ± standard deviation, 45.5 ± 15.6 years) who were scheduled to undergo reconstruction with ALT flaps between June 2020 and June 2021 were included in the prospective study. Before ALT flap transplantation, patients were scanned using CE-DISCO imaging. All acquired DISCO images of the 60 lower limbs (both sides from each patient) were analyzed using maximum intensity projection and volume rendering methods. Two experienced radiologists were employed to examine the patterns of the lateral circumflex femoral artery (LCFA), its branches, and perforators and their skin termini, which were compared with the operative findings. Results: Using CE-DISCO, the patterns of the LCFA and its branches were clearly identified in all patients. Four different origins of the LCFA were found among the 60 blood vessels: type I (44/60, 73.3%), type II (6/60, 10.0%), type III (8/60, 13.3%), and type IV (2/60, 3.3%). Owing to a lack of perforators entering the skin, two patients did not undergo ALT flap transplantation. For the remaining 28 patients, the ALT flaps in 26 patients were successfully operated without flap reselection during the operation, while the remaining two patients underwent other surgical procedures due to the thin diameter of the perforator or injury of the perforator during the operation. The success rate of flap transplantation was 92.8% (26/28). All transplanted flaps exhibited good blood supply and achieved primary healing without infection or delayed healing. Conclusion: CE-DISCO imaging can be an effective method for preoperative perforator imaging before ALT flap transplantation.

Resonance Characteristic Improvement of ZnO-Based FBAR Devices Fabricated on Thermally Annealed Bragg Reflectors

  • Yim, Mun-Hyuk;Kim, Dong-Hyun;Linh Mai;Giwan Yoon
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.4
    • /
    • pp.199-204
    • /
    • 2003
  • In this paper, we present the thermal annealing effects of the W/$SiO_2$ multi-layer reflectors in ZnO-based FBAR devices with cobalt (Co) electrodes in comparison with those with aluminum (Al) electrodes. Various thermal annealing conditions have been implemented on the W/$SiO_2$ multi-layer reflectors formed on p-type (100) silicon substrates. The resonance characteristics could be significantly improved due to the thermal annealing and were observed to depend strongly on the annealing conditions applied to the reflectors. Particularly, the FBAR devices with the W/$SiO_2$ multi- layer reflectors annealed at $400^{\circ}C$/30min have shown superior resonance characteristics in terms of return loss and quality-factor (Q-factor). In addition, the use of Co electrodes has resulted in further improvement of the resonance characteristics as compared with the Al electrodes. As a result, the combined use of both the thermal annealing and Co electrodes seems very useful to more effectively improve the resonance characteristics of the FBAR devices with the W/$SiO_2$ multi-layer reflectors.

Utility of Magnetic Resonance Imaging in the Diagnosis of Lung Adenocarcinoma with Extensive Necrosis: a Case Report

  • Choi, Sang Lim;Cha, Min Jae;Choi, Hye Won;Park, Byung-Joon;Kim, Mi Kyung;Kim, Jae Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Application of magnetic resonance imaging (MRI) for assessment of pulmonary disease has been limited, due to susceptibility to cardiac pulsation, respiratory motion, and inhomogeneity of the magnetic field of the lung. With technical advances of MRI and unmet clinical needs for more accurate diagnosis and assessment of the disease, however, the use of MRI for evaluation of the lung has broadened. Herein, we present a case of pneumonic-type lung adenocarcinoma in a patient with history of anaphylactic shock to iodinated contrast medium, in which MRI played a critical role for targeted lung biopsy and cancer staging. Through this paper, we would like to report potential value of MRI in assessment of lung cancer.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

A Study on Characteristics of Step-down Piezoelectric Transformer Using Transvers and Thickness Vibration mode (경방향과 두께방향 진동모드를 이용한 강압용 압전변압기의 특성에 관한 연구)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myung-Ho;Kwon, O-Yong;Lee, Jin-I;Lee, Won-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1511-1514
    • /
    • 2002
  • This paper presents design and construct of flat type step-down piezoelectric transformer for the application to AC adaptor. This piezoelectric transformer operated in resonance vibration mode. In this paper, finite element method(FEM) was used for analysing piezoelectric transformers. Stress and electric field of the transformer were simulated at resonance frequency. Using this simulation results, we manufactured improved Rosen type piezoelecric transfomer and measured its output characteristics. As results, output power was linearly increased by increasing input power at resonance frequency and it was found that the transformer an invariable output power for input power. From these results, we expect that this piezoelecric transfomer can be applied to small size and low capacitive AC adaptor.

  • PDF

Driving Characteristic of Thin-type Ultrasonic Motor (박형 초음파 모터의 구동특성)

  • Jeong, Seong-Su;Jun, Ho-Ik;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.343-343
    • /
    • 2008
  • Newly designed structure of a thin ultrasonic rotary motor was proposed. Thin brass plate was used as a cross shaped vibrator and eight ceramic plates were attached on the upper and bottom sides of the brass plate as in Figure 1. The thin type ultrasonic motor has the structure adherent piezoelectric ceramic on the top and bottom surface of the thin elastic body. The direction of polarization is decided so as to occur the elliptical displacement in regular sequence at touch point A, B, C and D of stator contacted with rotor. By applying two electric fields which have 90 degree phase difference on the ceramics, each contact points make rotational displacements as in figure 2. Finite element analysis program ATILA was used to find the optimal size of the stator. As a result of the simulation, elliptical displacements of the tips were obtained at off-resonance frequencies. The maximum displacements of the contact tips were obtained at the length of 16[mm], width of 6[mm] and thickness of 0.4[mm]. Changes of the resonance frequencies were inversely proportional to the length of ceramic and proportional to the width of ceramic. Elliptical motions of the contact tips. of the stator were consistently obtained at off resonance frequencies. From a prototype motor, speed of 600[rpm] was obtained at 20[Vrms].

  • PDF