• Title/Summary/Keyword: Resonance Parameters

Search Result 754, Processing Time 0.026 seconds

$^{87}Rb$ NMR Quadrupole Coupling Constants and Asymmetry Parameters in $RbMnCl_3$

  • Woo, Ae-Ja;Park, Young-Sun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.3 no.2
    • /
    • pp.84-89
    • /
    • 1999
  • The 87Rb quadrupole coupling constants (e2qQ/h) and the asymmetry parameters (η) in RbMnCl3 were determined from a nonlinear least-squares fit to the 87Rb NMR powder spectra. The spectra were acquired in the temperature range from 260K to 330K. An important feature in this work is the determination of the quadrupole coupling constants and the asymmetry parameters for two physically nonequivalent Rb sites, Rb(I) and Rb(II), as a function of temperature. In addition, a structural phase transition at room temperature was conformed with the changes in the quadrupole coupling constant and the asymmetry parameter of Rb(II) site.

  • PDF

Robust Reliability Analysis of Vibration Components

  • Huang, Hong-Zhong;Li, Yong-Hua;Ming J. Zuo
    • International Journal of Reliability and Applications
    • /
    • v.5 no.2
    • /
    • pp.59-74
    • /
    • 2004
  • There are many uncertain parameters associated with vibration components. Their physical parameters, the machining quality of vibration components, and the applied load acting on them are all uncertain. As a result, the natural frequency and the fatigue limits are also uncertain variables. In this paper, we express these parameters of vibration components and the frequency zone of resonance through interval models; this way, the robust reliability of the vibration components is defined. The robust reliability model measures and assesses the reliability of vibration components. The robust reliability of a cantilever beam is evaluated as an example. The results show that this method is reasonable for robust reliability analysis of vibration components because it does not require a large amount of failure data, it avoids the evaluation of the probability density function, and the computation is simple.

  • PDF

Parameters Affecting India Ink Artifacts on Opposed-Phase MR Images

  • Kim, Bo Ra;Ha, Dong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.341-350
    • /
    • 2019
  • Purpose: To determine the MR parameters affecting India ink artifacts on opposed-phase chemical shift magnetic resonance (MR) imaging. Materials and Methods: The use of a female Sprague-Dawley rat was approved by our Institutional Animal Care and Use Committee. Using an iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) images, which is a modified Dixon method, axial opposed-phase images of the abdominal cavity were obtained with different MR parameters: series 1, different repetition times (TRs; 400, 2000, and 4000 ms); series 2, different echo times (TEs; 10, 50, and 100 ms); series 3, different field of views (FOVs; 6, 8, 16, and 24 cm); series 4, different echo train lengths (ETLs; 2, 4, and 8); series 5, different bandwidths (25, 50, and 85); and series 6, different slice thicknesses (1, 2, 4, 8, and 16 mm). Artifacts on opposed images obtained with different parameters were compared subjectively by two radiologists. For objective analysis, the thickness of the artifact was measured. Spearman's correlation between altered MR parameters and thicknesses of India ink artifact was obtained via objective analysis. Results: India ink artifact was increasingly apparent using shorter TE, larger FOV and ETL, and thicker slices upon subjective analysis. The objective analysis revealed a strong negative correlation between the thickness of the artifact and TE (r = -0.870, P < 0.01); however, strong positive correlations were found between FOV (r = 0.854, P < 0.01) and slice thickness (r = 0.971, P < 0.01). Conclusion: India ink artifact was thicker with shorter TE, larger FOV, and larger slice thickness.

Anatomical and Pathological Findings of Magnetic Resonance Imaging in Idiopathic Sudden Sensorineural Hearing Loss

  • Kim, Min Bum;Lim, Jihyun;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.198-203
    • /
    • 2020
  • Background and Objectives: We sought to evaluate the diagnostic and prognostic value of measurable parameters of internal auditory canal (IAC) magnetic resonance imaging (MRI) in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). Subjects and Methods: We retrospectively reviewed the patients with ISSNHL who underwent IAC MRI from January 2008 to March 2019. Measurable parameters of IAC MRI, such as the diameter of the IAC, bony cochlear nerve canal, and cross-sectional area of the cochlear nerve, were measured by a single examiner. These parameters were then compared between the affected and healthy sides. Inner-ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis were also evaluated. The relationship between the surveyed parameters and the diagnosis of ISSNHL was assessed. Results: A total of 208 patients with ISSNHL were included. The measured parameters of IAC MRI were not different between the affected and healthy sides and were also not associated with the diagnosis of ISSNHL. However, inner-ear abnormalities of IAC MRI in ISSNHL displayed a significant association with worse hearing before and after treatment. An age that was older than 40 years also correlated with poorer outcomes. Further, inner-ear abnormalities were more frequently detected when IAC MRI was performed early after ISSNHL onset. Conclusions: Patients with ISSNHL and inner ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis identified via IAC MRI may experience poorer hearing outcomes. To detect such abnormal findings, it is recommended to perform IAC MRI early after the onset of ISSNHL.

Anatomical and Pathological Findings of Magnetic Resonance Imaging in Idiopathic Sudden Sensorineural Hearing Loss

  • Kim, Min Bum;Lim, Jihyun;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.198-203
    • /
    • 2020
  • Background and Objectives: We sought to evaluate the diagnostic and prognostic value of measurable parameters of internal auditory canal (IAC) magnetic resonance imaging (MRI) in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). Subjects and Methods: We retrospectively reviewed the patients with ISSNHL who underwent IAC MRI from January 2008 to March 2019. Measurable parameters of IAC MRI, such as the diameter of the IAC, bony cochlear nerve canal, and cross-sectional area of the cochlear nerve, were measured by a single examiner. These parameters were then compared between the affected and healthy sides. Inner-ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis were also evaluated. The relationship between the surveyed parameters and the diagnosis of ISSNHL was assessed. Results: A total of 208 patients with ISSNHL were included. The measured parameters of IAC MRI were not different between the affected and healthy sides and were also not associated with the diagnosis of ISSNHL. However, inner-ear abnormalities of IAC MRI in ISSNHL displayed a significant association with worse hearing before and after treatment. An age that was older than 40 years also correlated with poorer outcomes. Further, inner-ear abnormalities were more frequently detected when IAC MRI was performed early after ISSNHL onset. Conclusions: Patients with ISSNHL and inner ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis identified via IAC MRI may experience poorer hearing outcomes. To detect such abnormal findings, it is recommended to perform IAC MRI early after the onset of ISSNHL.

Basic Principles of Magnetic Resonance Imaging (자가공명영상(Magnetic Resonance Imaging)의 기본원리)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.7-20
    • /
    • 1999
  • Magnetic resonance imaging with its superior soft tissue contrast resolution and absence of beam hardening artifacts, combined with its ability to perform multiplanar imaging, is now effective tool in diagnostic imagings. Magnetic resonance is primarily a phenomenon that involves atomic nuclei. It provides totally new clinical informations with no known hazards through the use of very weak interactions with endogenous stable magnetic atomic nuclei. This article briefly summarizes the basic mechanism of generation and detection of the signals and general sorts of tissue properties which can influence the signals and thereby give rise to tissue contrast. It also describes how the machine-operating parameters can be used to manipulate the tissue contrast observed in the image.

  • PDF

The Approach Method for the Performance Comparison of Magnetic Resonance Imager (자기공명영상장치의 성능비교를 위한 접근방법)

  • Yi, Y.;Ju, H.Y.;Kim, I.Y.;Lee, M.W.;Ahn, C.B.;Oh, C.H.;Lee, H.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.75-78
    • /
    • 1997
  • In the accessment of the performance of a magnetic resonance imaging unit, there are many parameters to be measured. Such measured parameters are not often meaning by itself. Namely, it need to be compared with some standard. Since there is no gold standard MRI, only can be compared with a worldly renowned product. In this report, we attempted to compare a few MRI parameters for the accessment of the performance of 1 Tesla MRI unit which is domestically developed. Though we did not measure all the parameters related to hardware aspects and software aspects for the full comparison, there few parameters may elucidate some important aspects of MRI unit.

  • PDF

Bone Microarchitecture at the Femoral Attachment of the Posterior Cruciate Ligament (PCL) by Texture Analysis of Magnetic Resonance Imaging (MRI) in Patients with PCL Injury: an Indirect Reflection of Ligament Integrity

  • Kim, Hwan;Shin, YiRang;Kim, Sung-Hwan;Lee, Young Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • Purpose: (1) To evaluate the trabecular pattern at the femoral attachment of the posterior cruciate ligament (PCL) in patients with a PCL injury; (2) to analyze bone microarchitecture by applying gray level co-occurrence matrix (GLCM)-based texture analysis; and (3) to determine if there is a significant relationship between bone microarchitecture and posterior instability. Materials and Methods: The study included 96 patients with PCL tears. Trabecular patterns were evaluated on T2-weighted MRI qualitatively, and were evaluated by GLCM texture analysis quantitatively. The grades of posterior drawer test (PDT) and the degrees of posterior displacement on stress radiographs were recorded. The 96 patients were classified into two groups: acute and chronic injury. And 27 patients with no PCL injury were enrolled for control. Pearson's correlation coefficient and one-way ANOVA with Bonferroni test were conducted for statistical analyses. This protocol was approved by the Institutional Review Board. Results: A thick and anisotropic trabecular bone pattern was apparent in normal or acute injury (n = 57/61;93.4%), but was not prominent in chronic injury and posterior instability (n = 31/35;88.6%). Grades of PDT and degrees of posterior displacement on stress radiograph were not correlated with texture parameters. However, the texture analysis parameters of chronic injury were significantly different from those of acute injury and control groups (P < 0.05). Conclusion: The trabecular pattern and texture analysis parameters are useful in predicting posterior instability in patients with PCL injury. Evaluation of the bone microarchitecture resulting from altered biomechanics could advance the understanding of PCL function and improve the detection of PCL injury.

Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

  • Hyeongmin Jin;Hyun Joon An;Eui Kyu Chie;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 2022
  • Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air cavity in magnetic resonance-guided radiotherapy (MRgRT) for patients with pancreatic cancer. Methods: This study included nine patients that previously received MRgRT and their simulation CT and magnetic resonance (MR) images were collected. Air cavities were manually delineated on simulation CT and MR images in the treatment planning system for each patient. The synthetic CT images were generated using the deep learning model trained in a prior study. Two more plans with identical beam parameters were recalculated with ED maps that were either manually overridden by the cavities or derived from the synthetic CT. Dose calculation accuracy was explored in terms of dose-volume histogram parameters and gamma analysis. Results: The D95% averages were 48.80 Gy, 48.50 Gy, and 48.23 Gy for the original, manually assigned, and synthetic CT-based dose distributions, respectively. The greatest deviation was observed for one patient, whose D95% to synthetic CT was 1.84 Gy higher than the original plan. Conclusions: The variation of the air cavity position in the gastrointestinal area affects the treatment dose calculation. Synthetic CT-based ED modification would be a significant option for shortening the time-consuming process and improving MRgRT treatment accuracy.

The effects of temperature and porosity on resonance behavior of graphene platelet reinforced metal foams doubly-curved shells with geometric imperfection

  • Jiaqin Xu;Gui-Lin She
    • Geomechanics and Engineering
    • /
    • v.35 no.1
    • /
    • pp.81-93
    • /
    • 2023
  • Due to the unclear mechanism of the influence of temperature on the resonance problem of doubly curved shells, this article aims to explore this issue. When the ambient temperature rises, the composite structure will expand. If the thermal effects are considered, the resonance response will become more complex. In the design of structure, thermal effect is inevitable. Therefore, it is of significance to study the resonant behavior of doubly curved shell structures in thermal environment. In view of this, this paper extends the previous work (She and Ding 2023) to the case of the nonlinear principal resonance behavior of graphene platelet reinforced metal foams (GPLRMFs) doubly curved shells in thermal environment. The effect of uniform temperature field is taken into consideration in the constitutive equation, and the nonlinear motion control equation considering temperature effect is derived. The modified Lindstedt Poincare (MLP) method is used to obtain the resonance response of doubly curved shells. Finally, we study the effects of temperature changes, shell types, material parameters, initial geometric imperfection and prestress on the forced vibration behaviors. It can be found that, as the temperature goes up, the resonance position can be advanced.