• Title/Summary/Keyword: Resonance Frequency Analysis

Search Result 981, Processing Time 0.022 seconds

A Comparison Study of the Amplification Characteristics of the Seismic Station near Yedang Reservoir using Background Noise, S-wave and Coda wave Energy (배경잡음, S파 및 Coda파 에너지를 이용한 예당저수지 인근부지의 지반증폭 특성에 관한 비교 연구)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.632-642
    • /
    • 2015
  • Seismograms are composed of 3 characteristics, that is, seismic source, attenuation, and site amplification. Among them, site amplification characteristics should be considered significantly to estimate seismic source and attenuation characteristics with more confidence. This purpose of this study is to estimate the site amplification characteristics at each site using horizontal to vertical (H/V) spectral ratio method. This method, originally proposed by Nakamura (1989), has been applied to study the surface waves in microtremor records. It has been recently extended to the shear wave energy of strong motion and applied to the study of site amplification. This study analyzed the H/V spectral ratio of 6 ground motions respectively using observed data from 4 sites nearby in Yedang Reservoir. And then, site amplification effects at each site, from 3 kinds of seismic energies, that is, S waves, Coda waves energy, and background noise were compared each other. The results suggested that 4 sites showed its own characteristics of site amplification property in specific resonance frequency ranges (YDS: ~11 Hz, YDU: ~4 Hz, YDD: ~7 Hz). Comparison of this study to other studies using different analysis method can give us much more information about dynamic amplification of domestic sites characteristics and site classification.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

A Study on Inhibition of Bacterial Membrane Formation in Biofilm formed by Acne Bacteria in Valine through Property Analysis (물성 분석을 통한 Valine 의 여드름균 바이오필름 내부 세균막 형성 억제 연구)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seongkil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.163-170
    • /
    • 2021
  • This study was conducted to create a technology to remove acne bacteria with human-friendly materials. First, the Cutibacterium acnes (C. acnes) were adsorbed to the mica disc to grow, and then the biofilm was checked through an atomic microscope to see if the biofilm had grown. Based on the topographic image, the shape changed round, the size was 17% longer on average, and the phase value of the resonance frequency separating materials was observed as a single value, the biofilm grown by covering the extracellular polymeric substrate (EPS). As a result of processing 50 mM of amino acids in the matured biofilm, the concentration of C. acnes decreased when valine, serine, arginine and leucine were treated. Scanning with nanoindentation and AFM contact modes confirmed that the hardness of biofilms treated with Valine (Val) increased. This indicates that an AFM tip measured cell which may have more solidity than that of EPS. The experiment of fluorescent tagged to EPS displays an existence of EPS at the condition of 10 mM Val, but an inhibition of growth of EPS at the 50 mM Val. Number of C. acnes was also reduced above 10 mM of Val. Weak adhesion of biofilm generated from an inhibition of EPS formation seems to induce decrease of C. acnes. Accordingly, we elucidated that Val has an efficiency which eliminates C. acnes by approach of an inhibition of EPS.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.