• Title/Summary/Keyword: Resonance Coil

Search Result 375, Processing Time 0.027 seconds

A Case of Dural Arteriovenous Fistula of Superior Sagittal Sinus after Tamoxifen Treatment for Breast Cancer

  • Hwang, Sung-Kyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.204-207
    • /
    • 2015
  • We are reporting an unusual case of dural arteriovenous fistula (AVF) of the superior sagittal sinus (SSS) after tamoxifen treatment for breast cancer. A 30-year-old female arrived at the emergency room with a sudden headache and left sided weakness and sensory loss. In her past medical history, she was diagnosed with breast cancer 1 year prior, and subsequently underwent a breast conserving mastectomy with whole breast radiation and adjuvant chemotherapy with tamoxifen. At the time of admission, computed tomography showed a small acute intracerebral hemorrhage at the right parietal cortex, and magnetic resonance imaging showed that a dural AVF at the SSS with a prominent and tortuous venous enhancement along the centrum semiovale was present. Cerebral angiography showed that the dural AVF at the mid-portion of the SSS with meningeal arterial feeding vessels entering the wall of the SSS, then draining through the dilated cortical veins. Our patient had no signs of active malignancy or any abnormalities in her coagulation profile, so it can be concluded that the tamoxifen was the likely cause of the SSS thrombosis and dural AVF. The dural AVF was treated by an endovascular coil embolization for the arterialized segment of the SSS. The patient dramatically recovered favorably from left side motor and sensory deficit. The best clinical approach is to screen potential patients of tamoxifen hormonal therapy and educate them on the sign and symptoms of life threatening thromboembolic events while taking tamoxifen.

Eddy Loss Analysis and Parameter Optimization of the WPT System in Seawater

  • Zhang, Ke-Han;Zhu, Zheng-Biao;Du, Luo-Na;Song, Bao-Wei
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.778-788
    • /
    • 2018
  • Magnetic resonance wireless power transfer (WPT) in the marine environment can be utilized in many applications. However, energy loss in seawater through eddy loss (EL) is another consideration other than WPT in air. Therefore, the effect of system parameters on electric field intensity (EFI) needs to be measured and ELs calculated to optimize such a system. In this paper, the usually complicated analytical expression of EFI is simplified to the product of frequency, current, coil turns, and a coefficient to analyze the eddy current loss (ECL). Moreover, as the calculation of ECL through volume integral is time-consuming, the equivalent eddy loss impedance (EELI) is proposed to help designers determine the optimum parameters quickly. Then, a power distribution model in seawater is conceived based on the introduction of EELI. An optimization flow chart is also proposed according to this power distribution model, from which a prototype system is developed which can deliver 100 W at 90% efficiency with a gap of 30 mm and a frequency of 107.1 kHz.

Silent Magnetic Resonance Imaging Using Rotating and Projection Reconstruction (회전 경사자계와 사상 재구성을 이용한 무소음 자기 공명 영상법)

  • Chung, S.T.;Park, S.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.555-558
    • /
    • 1997
  • A new approach to silent MR imaging using a rotating DC gradient has been explored and experimentally studied. As is known, acoustic or sound noise has been one of the major problems in handling patients, mainly due to the fast gradient pulsings in interaction with the main magnetic field. The sound noise is also proportionally louder as the magnetic field strength becomes larger. In this article, we have described a new imaging technique using a mechanically rotating DC gradient coil as an approach toward silent MR imaging, i.e., a mechanically rotated DC gradient effectively replaces both the phase encoding as well as the readout gradient pulsings and data obtained in this manner provides a set of project ion data which later can be used or the projection reconstructionorwithsomeinterpolation techniques one can also perform conventional 2-D FFT (Fast Fourier Transform) image reconstruction. We found, with this new technique, that the sound noise intensity compared with the conventional imaging technique, such as spin echo sequence, is reduced down to -20.7 dB or about 117.5 times. The experimental pulse sequence and its principle are described and images obtained by the new silent MR imaging technique are reported.

  • PDF

Design and Analysis of Swingarm Type Rotary Actuator for Micro ODD (초소형 광디스크 드라이브용 스윙암 방식 로터리 엑츄에이터 설계 및 분석)

  • 김동욱;홍어진;박노철;박영필;김수경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.780-785
    • /
    • 2003
  • Recently the trends in information storage devices need small size, mobility, high capacity, and low power consumption etc. To satisfy those, the development of high performance actuator is an important issue. Compared with general linear actuator for optical disk drive, swingarm type rotary actuator is suitable to design in small form factor and has fast access time for random access. Swingarm actuator is designed considering the structural problem and the actuating force of VCM(Voice Coil Motor). The increase of mass caused by optical components makes vibration problems of swing-arm, therefore resonance frequency should be increased and inertia has to be reduced. ANSYS FEM tool is employed in optimizing swingarm. The VCM is designed using 3-D electro-magnetic analysis, and parameters of magnetic circuit are determined to matte large flux density. The large flux density enables to achieve low power consumption. VCM holder is designed to get the mass balance of total actuator and this balance reduces the magnitude of critical mode relative to pivot bearing, It is expected that swingarm type rotary actuator designed by this method is available to variable type of micro optical disk drives.

  • PDF

Omnidirectional Resonator in Three-Dimensional using a Globular Structure for Wireless Power Transfer (공 모양의 구조를 이용한 무선 전력 전송용 3차원 전 방향 공진기)

  • Kim, Donggeon;Seo, Chulhun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.22-26
    • /
    • 2016
  • In this paper, using the globular structure designed and implemented for the transmitter and the receiver resonant wireless power transfer(WPT). The coil of the transmitter was proposed to emit a magnetic energy in three-dimensional space by winding a ball shape. Each side of the transmitter has been designed to obtain a high Q value by a spiral structure. This solves the problem that the transfer efficiency decreases rapidly depending on the location in the conventional WPT. The resonance frequency is used 6.78 MHz and the distance between the trasnitter and the receiver is 200 mm. The transfer efficiency of the proposed WPT system is higher than 40% at all direction.

An algorithm to infer the central location of a solenoid coil for the mapping process based on harmonic analysis (조화해석 기반의 맵핑을 위한 솔레노이드 코일의 중심위치 추론 알고리즘)

  • Lee, Woo-Seung;Ahn, Min-Cheol;Hahn, Seung-Yong;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • Shimming, active and/or passive, is indispensable for most MR (magnetic resonance) magnets where homogeneous magnetic fields are required within target spaces. Generally, shimming consists of two steps, field mapping and correcting of fields, and they are recursively repeated until the target field homogeneity is reached. Thus, accuracy of the field mapping is crucial for fast and efficient shimming of MR magnets. For an accurate shimming, a "magnetic" center, which is a mathematical origin for harmonic analysis, must be carefully defined, Although the magnetic center is in general identical to the physical center of a magnet, it is not rare that both centers are different particularly in HTS (high temperature superconducting) magnets of which harmonic field errors, especially high orders, are significantly dependent on a location of the magnetic center. This paper presents a new algorithm, based on a field mapping theory with harmonic analysis, to define the best magnetic center of an MR magnet in terms of minimization of pre-shimming field errors. And the proposed algorithm is tested with simulation under gaussian noise environment.

A Study on the Application for the Vibration Active Control by using a Voice call type LOA (보이스코일형 LOA의 진동능동제어 시스템에의 응용에 관한 연구)

  • Jang, S.M.;Jeong, S.S.;Seo, J.H.;Kim, H.G.;Park, H.C.;Moon, S.J.;Chung, J.A.;Park, C.I.;Chung, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.317-319
    • /
    • 1996
  • In this paper, an active vibration control system using a voice coil type linear oscillating actuator(LOA) is studied to suppress structural vibration. Being compared with a hydraulic actuator, a LOA has simplified structure and requires a few elements in the driving system, so it has lots of merits with respect to economics and maintenance. The general mathematical dynamic model to obtain the algorithm for the realization of vibration active control system is treated. Actually, the performance test of the control system using LOA is carried out on a steel test structure under sinusoidal and white noise excitation. From this test it is conformed that acceleration level of test structure is reduced near the resonance region. In the future research on the application to large structures will be studied.

  • PDF

Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI (MRI용 차폐된 X,Y-경사자계코일의 최소전력설계)

  • Lee, D.R.;Kim, S.K.;Yang, Y.J.;Lee, H.K.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF

Solution Structure of the D/E Helix Linker of Skeletal Troponin-C: As Studied by Circular Dichroism and Two-Dimensional NMR Spectroscopy

  • 이원태;G. M. Anatharamaiah;Herbert C. Cheung;N. Rama Krishna
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.57-62
    • /
    • 1998
  • We have synthesized a 17-residue peptide with the amino acid sequence RQMKEDAKGKSEEELAD corresponding to residues 84-100 of chicken skeletal troponin C. This stretch of the protein sequence is in the middle one-third of the 32-residue 9-turn α-helix that connects the two globular domains of the dumbell-shaped molecule and includes the D/E linker helix. We describe here the solution conformation of the helix linker as studied by circular dichroism (CD) and two-dimensional nuclear magnetic resonance (2-D NMR) spectroscopy. The NOE connectivities together with the vicinal $^3J_{N{\alpha}}$ coupling constants suggest that the peptide exists in a fast conformational equilibrium among several secondary structure: a nascent helix near the N-terminus, a helix, and a substational population of extended and random coil forms. In addition, two interresidue α-α NOEs are observed suggesting a bent structure with a bend that includes the single glycine in position 92. These results are consistent with the ideas that in neutral solution the D/E linker region of the central helix in troponin C can adopt a helical conformation and the central helix may have a segmental flexibility around Gly 92.

Ultra Low Field Sensor Using GMI Effect in NiFe/Cu Wires

  • Kollu, Pratap;Kim, Doung-Young;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.35-39
    • /
    • 2007
  • A highly sensitive magnetic sensor using the Giant MagnetoImpedance effect has been developed. The sensor performance is studied and estimated. The sensor circuitry consists of a square wave generator (driving source), a sensing element in a form of composite wire of a 25 $\mu$m copper core electrodeposited with a thin layer of soft magnetic material ($Ni_{80}Fe_{20}$), and two amplifier stages for improving the gain, switching mechanism, scaler circuit, an AC power source driving the permeability of the magnetic coating layer of the sensing element into a dynamic state, and a signal pickup LC circuit formed by a pickup coil and an capacitor. Experimental studies on sensor have been carried out to investigate the key parameters in relation to the sensor sensitivity and resolution. The results showed that for high sensitivity and resolution, the frequency and magnitude of the ac driving current through the sensing element each has an optimum value, the resonance frequency of the signal pickup LC circuit should be equal to or twice as the driving frequency on the sensing element, and the anisotropy of the magnetic coating layer of the sensing wire element should be longitudinal.