• Title/Summary/Keyword: Resonance Coil

Search Result 377, Processing Time 0.029 seconds

High Field Superconducting Magnet Optimal Design for Nuclear Magnetic Resonance (NMR) Applications (핵자기공명(NMR) 응용을 위한 고자장 초전도 마그네트의 최적화 설계)

  • 고락길;조영식;권영길;진홍범;배준한;심기덕;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.150-153
    • /
    • 2000
  • NMR researches are required high field and high homogeneous super-conducting magnet. Thus superconducting magnets for NMR applications are designed with minimization of coil winding volume satisfied constraints such as field strength, field homogeneity, etc. In this paper, we are discussed optimal design of high field super-conducting magnet for NMR applications. For a design example, we designed unshielded superconducting magnet for 600MHz NMR spectrometer with 100mm room temperature bore size and obtained 14.1011[T] field strength and 1.33 ppm field homogeneity.

  • PDF

Endovascular Treatment of a Large Partially Thrombosed Basilar Tip Aneurysm

  • Kim, Young-Joon;Ko, Jung-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Despite the remarkable developments in neurosurgical and neuro-interventional procedures, the optimal treatment for large or giant partially thrombosed aneurysms with a mass effect remains controversial. The authors report a case of a partially thrombosed aneurysm with a mass effect, which was successfully treated by stent-assisted coil embolization. A 41-year-old man presented with headache. Brain computed tomography depicted an $18{\times}18$ mm sized thrombosed aneurysm in the interpeducular cistern. More than 80% of the aneurysm volume was filled with thrombus and the canalized portion beyond its neck measured $6.8{\times}5.6$ mm by diagnostic cerebral angiography. Stent-assisted endovascular coiling was performed on the canalized sac and the aneurysm was completely obliterated. Furthermore, most of the thrombosed aneurysm disappeared in the interpeduncular cistern was clearly visualized follow-up brain magnetic resonance imaging conducted at 21 months. The authors report a case of selective coiling of a large, partially thrombosed basilar tip aneurysm.

A Study on Magnetic Resonance Imaging Scan to Measure Bacterial Contamination and Disinfection of Equipment Status (자기공명영상(MRI)검사 장비의 세균오염도 측정 및 소독 실태에 관한 연구)

  • Lim, Chung-Hwan;Jeung, Seung-Woon;Kim, Eung-Hee
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.213-214
    • /
    • 2013
  • 본 연구는 밀폐된 공간과 다른 검사보다 시간이 오래 걸리는 자기공영상(MRI)검사 장비에서 환자와의 접촉이 많은 Head coil, Block, 밀폐된 공간인 Bore 등의 세균오염도를 측정 및 세균의 종류를 파악하고, 설문을 통하여 감염관리 실태를 파악하고 자기공명영상(MRI)장비의 소독 상태를 파악함으로써 환자의 병원감염에 대한 인식의 개선과 소독의 중요성을 제시하고자 한다.

  • PDF

The Study on the Improvement on Damping Ratio of Dynamic Absorber using Silicon Oil (실리콘 오일을 이용한 동흡진기 감쇠 성능 향상에 대한 연구)

  • Kwak, Y.S.;Kim, W.H.;Joo, W.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.113-118
    • /
    • 2011
  • Many kinds of dynamic absorbers have been used to reduce the vibration of machineries and structures. In the typical ones, however low damping capacity, durability and limited install condition restrict their application. In this study, high damped dynamic absorber was proposed for diesel generator set. Developed absorber is composed with mass and coil springs. Silicone oil was filled inside the narrow gap between mass and casing. Viscous damping of silicon oil act as additional damping so that proposed dynamic absorber is suitable for D/G set which have adjacent resonance frequency to operation speed. The performance of the dynamic absorber was confirmed through the actual test on diesel engine generator set.

  • PDF

Impedance Properties of Thin Film Inductors by Fabricated Wet Etching Method (습식 식각법으로 제조된 박막 인덕터의 임피턴스 특성)

  • 김현식;송재성;오영우
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.813-818
    • /
    • 1997
  • In this study the thin film air core and magnetic core inductors consisting of planar coil and/or CoNbZr amorphous magnetic layers on a Si substrate were fabricated as spiral type by using rf magnetron sputtering and wet etching methods. The etchant solution was achieved by iron chloride solution(17.5 mol%) mixed with HF (20 mol%) during 150 sec which etched Cu films and CoNbZr/Cu/CoNbZr multi-layer films. They were about 10${\mu}{\textrm}{m}$ of thickness and 10$\times$10 mm$^2$of size. The properties of thin film magnetic core inductor were 400 nH of Q value at 10 MHz and the resonance frequency was about 300 MHz.

  • PDF

Fast MR Imaging Technique by Using Locally-Linear Gradient Field (부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법)

  • 양윤정;이종권
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF

Intensity non-uniformity correction with k-space data

  • 김양현;류완석;김대원;류택현;최환준;김시승;현정호;정성택
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.98-98
    • /
    • 2002
  • 목적: RF Coil sensitivity 또는 MRI system의 여러 요인들로 인해서 생길 수 있는 영상의 Bias field 즉, 유난히 밝거나 어두운 부분을 raw data 의 low frequency 값들을 임의로 변화를 줌으로써 어느 정도 보정이 가능하다. 대상 및 방법: Bias field로 인해서 분석에 어려움이 있는 이미지의 k-space 데이터를 가지고 있으면 부위에 상관없이 모두 가능하다. k-space에서 얻어진 raw data를 Kx와 Ky의 2-D로 표현한 후에 DC 성분에 해당하는 영점을 그대로 놔둔 상태에서 영점 주변으로 일정 범위 안에 있는 low frequency 성분 값들을 FT(Fourier Transform)를 거치기 전에 0으로 바꾼 후에 image processing을 거치도록 한다.

  • PDF

Study on the Implementation of the Digital Controller of High-Speed PWM Current Amplifier (디지털 제어 방식의 고속 PWM 전류 증폭기의 구현에 관한 연구)

  • Ko, Deog-Hwa;Baek, Kwang-Ryul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.2
    • /
    • pp.97-103
    • /
    • 2002
  • This paper deals with a PWM(Pulse Width Modulation) current amplifier using digital controller in order to generate a gradient magnetic field far the MRI(Magnetic Resonance Image) system. Because of tolerance of discrete devices, it is difficult to set accurate values of the control parameters and to make an analog-controlling circuit. However, using digital controller, it is possible to set exact control parameters and to adopt a modern control techniques. It is shown that the digital controller will highly enhance the output current response and it will improve the quality of the MRI.

Control of chaotic dynamics by magnetorheological damping of a pendulum vibration absorber

  • Kecik, Krzysztof
    • Structural Engineering and Mechanics
    • /
    • v.51 no.5
    • /
    • pp.743-754
    • /
    • 2014
  • Investigations of regular and chaotic vibrations of the autoparametric pendulum absorber suspended on a nonlinear coil spring and a magnetorheological damper are presented in the paper. Application of a semi-active damper allows controlling the dangerous motion without stooping of system and additionally gives new possibilities for designers. The investigations are curried out close to the main parametric resonance. Obtained numerical and experimental results show that the semi-active suspension may reduce dangerous motion and it also allows to maintain the pendulum at a given attractor or to jump to another one. Moreover, the results show that, for some parameters, MR damping may transit to chaotic motions.

Design and Analysis of a Vibration-driven AA Size Electromagnetic Energy Harvester Using Magnetic Spring

  • Foisal, Abu Riduan Md.;Chung, Gwiy-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.125-128
    • /
    • 2012
  • This paper describes the design, simulation and characterization of an AA size electromagnetic energy harvester that is capable of converting environmental vibration into electrical energy. A magnetic spring technique is used to scavenge energy from low frequency external vibrations. The generator is characterized by ANSYS 2D finite element analysis, and optimized in terms of moving mass, fixed magnet size, coil width and load resistance. The optimized energy harvester is able to generate 53.5 mW of average power at 8.1 Hz resonance frequency, with a displacement of 0.5 mm.