Kernel 특성에 따른 MTF 평가 및 임상적 적용에 관한 연구 (MTF Evaluation and Clinical Application according to the Characteristic Kernels in the Computed Tomogrsphy)

  • 유병규;이종석;권대철
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.55-64
    • /
    • 2007
  • CT에서 커널에 따른 노이즈, 공간분해능 및 MTF를 측정하고 임상에 적용하여 영상의 질을 평가하였다. 커널은 B30 (body medium smooth), H30 (head medium smooth), S80 (special), U95 (ultra sharp)를 이용하여 측정하였다. 커널에 따른 결과에서 노이즈는 B30 (7.6 HU), U95 (38.2 HU)이었고, 공간분해능은 H30, B30 커널이 0.8 mm, U95 커널은 0.6 mm로 33.3% 영상의 질이 향상되었다. MTF (50%, 10%, 2%)에서 H30 커널은 3.25 5.68, 7.45 Ip/cm, B30 커널은 3.84, 6.25, 7.72 Ip/cm, S80 커널에서는 4.69, 9.49, 12.34 Ip/cm, U95 커널은 14.19, 20.31, 24.67 Ip/cm이었다. 커널 종류별로 영상의 임상 적용에서 두부는 H30 커널, 복부는 B30 커널, 측두골 및 폐에서는 U95 커널이 임상적 평가가 높았다. 임상에서 진단에 적용하기 위해서는 검사 부위에 맞는 커널을 선택하여 검사하여야 한다.

  • PDF

광자선 치료시 Setup 오차에 따르는 Multi-leaf Collimator의 Scallop Penumbra 변화 효과 (The Dosimetric Effects on Scallop Penumbra from Multi-leaf Collimator by Daily Patient Setup Error in Radiation Therapy with Photon)

  • 이병용;조영갑;장혜숙
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.333-338
    • /
    • 1996
  • 목적 : 반복되는 환자 치료에서 환자의 Setup 오차가 Multi-leaf Collimator의 scallop penumbra에 미치는 효과와 이의 임상적 의미를 살펴보고자 하였다. 대상 및 방법 : MLC의 leaf 방향에 대해 $0^{circ},{\;}15^{circ},{\;}30^{circ},{\;}45^{circ},{\;}60^{circ},{\;}75^{circ}$ block 모양을 MLC와 통상적인 block으로 만들었다. 팬톰내에서 필름 측정법으로 통상적인 블록과 MLC가 만든 치료면의 penumbra 차이를 비교하였다. 방사선 치료는 30회 반복할 때의 setup 오차가 고려된 선량분포를 중첩방식으로 구하였다. 위치 변화값은 연구보고 수치를 근거하여 구하였다. 결과 : 평균 4mm setup error를 갖는 모델에서 1cm 폭분해능을 갖는 MLC가 만든 penumbra은 기존 차폐 블록에서 생긴 penumbra 보다 차폐 모양에 따라 $0\~3mm$ 증가하는 효과를 볼 수 있었다. 결론 : 치료 조사면을 결정할 때 MLC를 사용하더라도 ICRU 50에 따라 환자의 움직임을 고려하여 치료조사면을 결정하였다면, 기존의 방식과 동일하게 치료면을 정할 수 있으며, 필요에 따라 3mm의 여유를 두면 MLC 치료 조사면 내에 치료 부위가 충분히 포함된다.

  • PDF

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발 (Development of Imaging Gamma Probe Using the Position Sensitive PMTube)

  • 봉정균;김희중;소수길;김한명;이종두;권수일
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.107-113
    • /
    • 1999
  • 본 연구의 목적은 작은 부위의 종양 또는 수술후 잔여종양을 검출할 수 있는 소형 고성능 영상용 감마프로브를 개발하는 것이다. 감마프로브의 검출기 시스템을 위해 위치민감형 광전자증배관(PSPMT)을 사용하였고, -1000V의 고전압을 공급하였다. 섬광체는 직영 7.62cm, 두께 9.5mm인 NaI(Tl)를 사용하였으며, 광학그리스를 이용하여 NaI(Tl)와 PSPMT를 접합시켰다. 조준기는 평형육각구멍조준기로써 직경 1.3mm, 격벽 두께 0.22mm, 그리고 길이 40mm이었다. 신호처리시스템은 위치신호처리와 트리거신호처리로 구분되며, 위치신호처리는 전단증폭기, 주증폭기를 거쳐 가산, 감산, 제산신호회로를 이용하여 얻었고, 트리거신호는 가산증폭기, 일정분획식별기 그리고 게이트 모듈을 이용하여 얻었다. 데이터 획득은 Gamma-PF 인터페이스 보드를 경우유하여 PIP 소프트웨어와 펜티엄 PC에 제어되었다. 영상연구를 위해 점선원을 이용하여 장균이도 영상과 슬릿마스크 영상을 얻었다. 그리고 조준기를 사용하여 두 개의 구멍팬텀 영상을 얻었다. 고유공간분해능은 3.97mm이었으며, 시스템 공간분해능은 5.97mm이었다. PSPMT를 이용하여 개발한 소형 감마프로브에 의해 획득된 팬텀영상은 좋은 영상질을 보여주었으며, 임상적용을 위해서는 영상특성의 최적화 연구가 계속되어야할 것으로 생각된다.

  • PDF

1.0 Tesla 자기 공명 진단 장치의 개발 (Development of 1.0 Tesla Compact MRI System)

  • 이흥규;오창현;안창범;장용호;신동희;이근남;장기현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향 (Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography)

  • 김종석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템 (A low noise, wideband signal receiver for photoacoustic microscopy)

  • 한원국;문주영;박성훈;장진호
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.507-517
    • /
    • 2022
  • 광음향 현미경은 높은 공간 해상도와 높은 대조도를 갖는 영상을 제공할 수 있어 생명과학 연구와 의료응용에 있어 유용하다. 광음향 현미경은 레이저 펄스 송신 후 생체조직에서 발생하는 광음향 신호를 수신하여 영상을 구성한다. 일반적으로 광음향 신호의 크기는 작기 때문에, 고품질의 광음향 현미경 영상을 얻기 위해서는 고성능의 광학 및 음향 모듈과 더불어 신호 수신용 고성능 시스템이 필요하다. 그러나 대부분의 광음향 현미경 시스템은 광음향 신호의 수신, 증폭, 품질향상, 디지털화를 위해 여러 상용 장비의 조합으로 구성된다. 이러한 이유로 광음향 현미경은 부피가 클 수밖에 없으며, 최적의 성능을 제공하기 어렵다. 본 논문에서는 향상된 신호 대 잡음비와 대조도를 제공할 수 있는 광음향 수신 시스템의 구조를 제안하고 성능 평가 결과를 제시한다. 개발한 저잡음 광대역 광음향 신호 수신 시스템은 두개의 저잡음 증폭기, 두 개의 가변 이득 증폭기, 아날로그 필터, 아날로그 디지털 변환기, 그리고 디지털 제어 로직으로 구성되어 있다. 개발된 시스템의 영상 성능은 생체 모사 혈관 팬텀, 와이어 타겟 팬텀 영상 실험을 통하여 상용 신호수신 시스템의 성능과 비교하여 평가하였다. 영상 비교 실험을 통해 개발한 광음향 현미경 시스템이 상용 장비 보다 신호 대 잡음비는 6.7 dB 이상 높았고, 영상의 대조도는 3 dB 이상 높다는 것을 확인하였다.

이중 에너지 전산화 단층촬영 ECG Gating High Pitch Chest Pain Protocol 모드를 이용한 방사선량과 영상 품질에 관한 연구 (A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode)

  • 김경립;성순기;김창현;곽종혁
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 2022
  • 본 연구는 심전도 게이팅을 한 방법과 심전도 게이팅 없이 검사하는 방법으로 검사하여 대동맥 뿌리 영상을 비교하는 것이며 high pitch(flash) chest pain protocol 방법으로 검사한 영상들과 기존의 방식으로 심전도 게이팅 없이 검사한 환자의 대동맥 뿌리 영상의 질환 유무를 관찰하였다. High pitch(flash) chest pain protocol과 일반적인 chest pain protocol로 AAPM 팬텀을 스캔하였으며 이렇게 획득된 팬텀 영상을 가지고 동일한 영상 품질을 가지는 파라메타 값을 조절하고 방사선량, 즉 CTDI 값을 비교해 보았다. 심전도 게이팅을 함으로 해서 상행대동맥의 이미지 왜곡은 기존의 심전도 게이팅을 하지 않은 검사방법보다 월등하게 감소시킬 수 있었고 대동맥 뿌리의 영상 품질은 향상되었다. 영상 이미지 품질의 차이를 보이지 않는 파라메타 범위 내에서, high-pitch chest pain protocol로 검사하였을 때 CTDI 값이 더 낮게 나왔으므로 방사선량 감소에도 이점이 있음을 알 수 있었다. 심장과 관련된 분야에서 선량 감소 모드를 이용하여 대동맥 박리와 같은 진단 분야에 응용하여 적용한다면 획기적인 피폭선량 감소 효과뿐만 아니라 빠른 진단과 함께 신속한 치료가 필요한 환자들에게 매우 중요한 검사방법이 될 것으로 사료된다.

68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구 (Study of 68Ga Labelled PET/CT Scan Parameters Optimization)

  • 곽인석;이혁;김시활;문승철
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구 (A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam)

  • 최상현;허현도;김성훈;지영훈;김금배;김우철;김헌정;신동오;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.216-223
    • /
    • 2011
  • 최근 PTW사에서는 물등가물질로 구성되어 있고, 측정체적(sensitive volume, $0.002cm^3$)이 매우 작은 MicroLion 액체이온함을 내놓았다. 본 연구의 목적은 외부방사선 치료용 광자빔에 대해 MicroLion 액체이온함의 선량선형성, 선량률의존성, 공간분해능, 그리고 출력인수와 같은 선량측정학적 특성을 조사하는 것이다. 이 결과를 Semiflex 이온함($0.125cm^3$), Pinpoint 이온함($0.015cm^3$), 다이오드 검출기($0.0025mm^3$)의 결과와 비교분석하여 소조사면 측정에 적절한지를 평가하고 자 하였다. Varian clinac 2300 C/D의 6 MV 광자빔에서 측정하였으며, MP3 물팬톰(PTW, Freiburg)을 이용하였다. 공간분해능은 반음영(penumbra)을 측정하여 평가하였으며, $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지 다양한 조사면에 대하여 측정하였다. 출력인수는 $0.5{\times}0.5cm^2$에서 $40{\times}40cm^2$에 대하여 측정하였다. 선량에 따른 MicroLion 액체이온함의 측정값은 선형적인 비례성을 보였다. 그러나 선량률은 100 MU/min와 600 MU/min에 의한 측정값의 차이가 최대 5%의 차이를 보였으며, 선량율이 커질수록 출력선량이 작아지는 결과를 보였다. 공간분해능의 경우 조사면 $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지의 측방선량분포 비교에서 Semiflex 이온함을 제외한 다른 모든 검출기들의 경우 2% 이내에서 일치하였다. 출력선량은 $2{\times}2cm^2$에서 $10{\times}10cm^2$ 조사면에서 Semiflex 검출기 대비 모든 검출기가 2% 이내에서 잘 일치하였다. 연구 결과 MicroLion 액체이온함은 물등가물질로 이루어져 있으며, 감응 면적이 매우 작기 때문에 소조사면에서 매우 유용할 것으로 사료된다.