재구성 알고리즘 변화에 따른 CT 영상의 화질 평가 (The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images)

  • 한동균;박건진;고신관
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

초음파 영상에서의 초고분해능 합성곱 신경망 알고리즘의 시뮬레이션 및 실험 연구 (Simulation and Experimental Studies of Super Resolution Convolutional Neural Network Algorithm in Ultrasound Image)

  • 이영진
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.693-699
    • /
    • 2023
  • 초음파는 의료분야에서 비파괴적 및 비침습적인 질병 진단에 널리 활용되고 있다. 진단의료영상의 질병진단 정확도를 향상시키기 위하여 공간 분해능을 향상시키는 것은 매우 중요하다. 본 연구에서는 초음파 영상에서의 초고분해능 합성곱 신경망 알고리즘 (super resolution convolutional neural network, SRCNN)을 모델링하여 적용 가능성을 분석하고자 한다. 연구는 Field II 시뮬레이션과 open source로 제공되는 임상 간 혈관종 초음파 영상을 사용한 실험 연구로 수행되었다. 제안하는 SRCNN 알고리즘은 저분해능 (low resolution, LR)에서 고분해능 (high resolution)으로 end-to-end 방식의 학습이 적용될 수 있도록 모델링하였다. 시뮬레이션 결과 Field II 프로그램을 통한 팬텀 영상에서의 반치폭 값은 SRCNN을 사용하였을 때 LR에 비하여 41.01% 향상되는 것을 확인하였다. 또한, 최대신호대잡음비 (peak to signal to noise ratio, PSNR)와 구조적 유사도 지표 (structural similarity index, SSIM)) 평가 결과는 시뮬레이션과 실제 간 혈관종 영상에서 SRCNN이 가장 우수한 값으로 도출되었다. 결론적으로 SRCNN의 초음파 영상에서의 적용 가능성을 증명하였고, 나아가 다양한 진단의료분야에서의 사용이 가능할 것으로 기대한다.

초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구 (A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination)

  • 서선열;이진옥;김영란
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.957-964
    • /
    • 2023
  • 본 연구는 시중에 판매되고 있는 다양한 성분과 제형의 손 소독제들을 전파 매질로 활용하여 초음파 검사를 진행한 후 획득한 영상을 평가·비교하여 기존의 초음파 젤의 대체 가능성을 확인하고자 하였다. 연구 방법으로는 점도가 낮은 liquid type을 제외한 gel type, cream type, foam type의 제형의 제품들을 선정해 에탄올 62% gel type 1개와 cream type 1개, 벤잘코늄 염화물 0.066% cream type 1개와 foam type 1개를 각각 초음파 매질로 사용하여, 축방향 & 측방향 분해능, 투과심도, probe와 phantom 사이의 공기층 형성유무에 관한 영상 평가를 진행하였다. 그 결과, 축방향 & 측방향 분해능 평가와 투과심도 평가에서 4개 실험군 모두 평가 기준에 적합한 결과가 나왔다. 그러나 foam type의 경우 분해능과 투과심도의 평가 기준에는 적합하지만 영상 평가 시 관찰 중심부를 제외한 양 측면부에서 어두운 음영으로 나타났다. 해당 실험을 통해 foam type을 제외한 나머지 3종의 손 소독제는 초음파 젤을 대체할 수 있을 것으로 사료된다.

전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성 (Utility of Wide Beam Reconstruction in Whole Body Bone Scan)

  • 김정열;강청구;박민수;박훈희;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2010
  • UltraSPECT사의 Wide Beam Reconstruction (WBR)은 노이즈(Noise)와 조준기의 광속 확산 함수 효과(Beam spread function effect)를 제거하고 환자와의 거리를 자동적으로 보상하여 높은 해상도와 대조도를 제공할 수 있어 영상 획득 시간을 짧게 할 수 있고 상당한 영상 질 향상에 도움을 준다고 보고되고 있다. 이에 본 연구에서는 핵의학 분야에서 가장 흔히 이용되는 전신 뼈 스캔에 대해 WBR의 임상적 적용에 대한 유용성을 알아보고자 한다. XpressBone (WBR)의 성능 실험을 위하여 NEMA에서 제공하는 방법에 의하여 선원(Line source)과 SPECT Phantom을 이용하여 공간 분해능을 측정 분석하였다. 실험방법은 선원의 총 계수치를 200 kcps에서 300 kcps로 변화시켜 측정하였으며, SPECT Phantom은 매트릭스 크기를 변화시켜 측정하여 공간분해능에 대한 분석을 하였다. 또한 2009년 1월부터 2009년 9월까지 본원을 내원하여 뼈 스캔을 시행 받은 환자 40명을 두 군으로 나누어 임상 연구를 시행하였다. 1군은 $^{99m}Tc$-HDP 740 MBq (20mCi)를 투여하고 검사속도(20, 30 cm/min)를 변화시켰고, 2군은 동일한 검사속도에서 $^{99m}Tc$-HDP의 투여량을 변화시켜 영상을 획득하여 Standard data와 WBR기법으로 재구성한 영상을 비교 평가하였다. 분석방법은 대퇴골체부에서 뼈와 연부조직간 섭취비(Femur to tissue ratio: FTR)를 측정한 정량적인 분석과 핵의학과 전문의와 5년 이상의 실무경험을 가진 방사선사가 육안적인 분석을 하여 비교 평가하였다. 성능 실험에서 선원을 사용하여 실험한 결과 Planar WBR data는 Standard data에 비하여 분해능이 약 10% 향상되었으며, WBR 반치폭(Full-Width at Half-Maximum)은 16% 향상되었다(Standard data 8.45, WBR data 7.09). SPECT Phantom에서는 약 50%의 분해능이 향상되었으며, WBR 반치폭은 50% 향상되었다(Standard data 3.52, WBR data 1.65). 임상 연구에서는 $^{99m}Tc$-HDP 투여량을 고정시키고 검사속도를 20cm/min과 30 cm/min로 변화시킨 1군에서 Standard data와 WBR data의 전신 뼈 스캔 전면 영상에서 뼈 대비 연부조직간 섭취비는 통계적으로 유의한 차이를 보이지 않았다 (p=0.07). 검사속도를 고정하고 $^{99m}Tc$-HDP 투여량을 변화시킨 2군에서는 Standard data와 WBR data간의 전신 뼈 스캔전면 영상에서는 통계적으로 유의한 차이를 보이지 않았다 (p=0.458). 영상의 육안적 분석에서도 두 군 간 유의한 차이를 보이지 않았다(p>0.05). NEMA test 결과 WBR 기법의 영상에서 분해능이 향상되는 결과를 나타내었고, 임상 실험에서는 기존 재구성 방법에서의 동일한 해상도를 가지면서도 검사시간을 단축시킬 수 있었으며 방사성의약품의 투여량도 줄일 수 있었다. 이미 알려진 바와 같이 WBR은 노이즈를 감소시켜 신호 대 잡음비를 증강시키는 새로운 영상 재구성 방법임을 확인 할 수 있으며 동일한 검사속도에서 투여량을 감소시킬 수 있어 수신자의 피폭선량 경감과 검사시간을 단축할 수 있었으며 임상 현장에서 유용하게 이용되리라 사료된다.

  • PDF

초음파 의료영상에서 매질의 평균음속도 측정방법에 대한 연구 (An Efficient Method for Estimating Average Speed of Sound in Ultrasound Medical Imaging)

  • 정목근;권성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.321-325
    • /
    • 1998
  • 일반적으로 현재의 초음파 의료영상시스템에서 지연시간의 계산에 사용하는 음속도는 인체의연조직에서의 평균속도인 1540m/s 의 값을 이용한다. 그러나 사람마다 혹은 매질의 특성에 따라 초음파의 속도가 크게 차이가 나서 고정된 속도를 이용한 집속 지연시간 계산에는 오차가 발생한다. 이는 해상도의 저하를 가져올 뿐만 아니라, 매질의 기하학적인 크기나 거리정보가 필요한, 심장이나 신장의 용적을 계산과 같은 경우에는 큰 오차를 가져온다. 따라서 매질의 속도를 정확히 구하는 것이 해상도 향상의 중요한 관건의 하나임을 알 수가 있다. 본 논문에서는 이를 위해 매질내의 관심영역에서의 밝기를 최대화시켜주는 접속지연시간 프로파일을 구해 매질 내에서의 옴파의 속도를 측정하여 실제 초음파 팬텀에 적응하여 좋은 결과를 얻을 수 있었다.

  • PDF

2D Image Construction from Low Resolution Response of a New Non-invasive Measurement for Medical Application

  • Hieda, Ichiro;Nam, Ki-Chang
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.385-393
    • /
    • 2005
  • This paper presents an application of digital signal processing to data acquired by the radio imaging method (RIM) that was adopted to measure moisture distribution inside the human body. RIM was originally developed for the mining industry; we are applying the method to a biomedical measurement because of its simplicity, economy, and safety. When a two-dimensional image was constructed from the measured data, the method provided insufficient resolution because the wavelength of the measurement medium, a weak electromagnetic wave in a VHF band, was longer than human tissues. We built and measured a phantom, a model simulating the human body, consisting of two water tanks representing large internal organs. A digital equalizer was applied to the measured values as a weight function, and images were reconstructed that corresponded to the original shape of the two water tanks. As a result, a two-dimensional image containing two individual peaks corresponding to the original two small water tanks was constructed. The result suggests the method was applicable to biomedical measurement by the assistance of digital signal processing. This technique may be applicable to home-based medical care and other situations in which safety, simplicity, and economy are important.

  • PDF

Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.

자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究) (A Study on Locational Control of Motion Ghost in Magnetic Imaging System)

  • 이후민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.439-443
    • /
    • 2019
  • To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction in a CZT pixelated semiconductor gamma camera system. The gamma camera system simulated is a CZT pixelated semiconductor detector with a pixel-matched parallel-hole collimator and the spatial resolution phatnom was designed with the Geant4 Application for Tomography Emission (GATE). In addition, a noise reduction algorithm with a median filter using an improved thresholding method is developed and we applied our proposed algorithm to an acquired spatial resolution phantom image. According to the results, the proposed median filter improved the noise characteristics compared to a conventional median filter. In particular, the average for normalized noise power spectrum, contrast to noise ratio, and coefficient of variation results using the proposed median filter were 10, 1.11, and 1.19 times better than results using conventional median filter, respectively. In conclusion, our results show that the proposed median filter using improved the thresholding method results in high imaging performance when applied in a CZT semiconductor gamma camera system.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.