• Title/Summary/Keyword: Resistance value

Search Result 2,591, Processing Time 0.028 seconds

The annealing effects of Au/Te/Au n-GaAs structure (Au/Te/Au/ n-GaAs구조의 열처리 효과)

  • 정성훈;송복식;문동찬;김선태
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1013-1018
    • /
    • 1996
  • The annealing effects of Au/Te/Au/n-GaAs structure was investigated by using x-ray diffraction, scanning electron microscope, the specific contact resistance and I-V measurement. Increasing the annealing temperature, the intensity of Au-Ga peak by X-ray diffraction was increased. The Ga$\_$2/Te$\_$3/peak got evident for the samples annealed at 400.deg. C and GaAs peak by recrystallization appeared for the samples annealed at 500.deg. C. The variation from the schottky to low resistance contact was confirmed by I-V curve. The lowest value of the specific contact resistance of the samples annealed at 500.deg. C was 3.8*10$\^$-5/.ohm.-cm$\^$2/ but the value increased above 600.deg. C.

  • PDF

Cure Characteristics, Mechanical Property and Ozone Resistance of Natural Rubber/Bromo Isobutylene Isoprene Rubber Blend

  • Choi, Im Cheol;Lee, Won-Ki;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2018
  • Natural rubber (NR) and bromo-isobutylene-isoprene rubber (BIIR) were compounded with other formulation chemicals through polymer blending via a mechanical mixing method. After rubber vulcanization by hot-press compression molding, the cure characteristics, mechanical properties, and ozone resistance of the NR/BIIR blends were measured. As the BIIR content increased, the maximum torque of the blends decreased, while the optimum cure time and scorch time tended to increase. Furthermore, the hardness of the blends increased with increasing BIIR content, reaching the maximum value at 75 wt% BIIR, and decreased with a further increase in the BIIR loading. The tensile strength and elongation at break decreased with an increase in the BIIR content, reaching the minimum value at 75 wt% BIIR, and increased with a further increase in the BIIR content. In the ozone resistance test, cracks were not generated when the BIIR content was more than 75 wt%.

Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정값 비교)

  • Lee, Snag-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

Analysis of Ground Resistance Reduction Effect by Common use of Ground Poles (접지극의 공용화를 통한 접지저항 저감효과 분석)

  • Hong Sung Taek;Lee Eun Chun;Shin Gang Wook
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.440-442
    • /
    • 2004
  • The ground resistance of middle scale ground pole was measured by using the 'fall of potential method' suggested by IEEE However, the measured resistance value was lower than the minimum value required To solve this problem. ground pole was set to be used commonly. In this research. ground resistance was measured using the newly suggested method and the results were analyzed to see if they satisfied the domestic regulation The results of this research will be applied to the management works as well as the establishment of new plan.

  • PDF

Electrical Resistance Characteristics of Conductive Cement Composite with Deterioration Damage (열화손상이 발생된 전도성시멘트복합체의 전기저항특성)

  • Kim, Young-Min;Lee, Gun Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.149-150
    • /
    • 2020
  • Granting self-sensing performance in a building is an important performance to ensure the degree of damage and safety of the building. Since the current research is being conducted in the state before deterioration loss occurs, it is necessary to confirm whether the self-sensing performance is maintained even in the damaged conductive cement composite. As part of the study, electrical resistance characteristics were analyzed in conductive cement composites in which freeze-thawing and chemical corrosion occurred. As a result, it was found that the change in electrical resistance value due to freeze-thawing was not as large as 1%, and chemical corrosion occurred. It was found that the change in electrical resistance value of the tested specimen increased by about 10%.

  • PDF

Effect of Enhancers on the Electrical Properties of Skin: The Effect of Azone and Ethanol

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 1994
  • The effect of Azone and ethanol on the electrical properties of human and hairless mouse skin was studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from Nyquist plot. After the treatment of human-heat separated epidermis with Azone, contrary to the expectation, resistance increased about 60% and it did not change with time. Capacitance also increased; immediately after the treatment, it was about 110% of pretreatment value and it increased further with time. On the other hand, when hairless mouse skin was treated with Azone, marked changes occured; resistance fell almost to the value of bathing medium itself and capacitance increased to about 200% of its pretreatment value. Similar result were obtained when hairless mouse skin was treated with 100% ethanol. The results suggest that there are differences in the strength of barrier properties of stratum corneum (SC) between human and hairless mouse skin. Overall, the results provide further mechanistic insight into ion conduction through the skin and into the role of SC lipids in skin capacitance.

  • PDF

Membrane Fouling Effect with Organic-Inorganic Materials Using the Membrane Separation in Drinking Water Treatment Process (분리막을 이용한 정수처리공정에서 유, 무기물질이 막오염에 끼치는 영향)

  • 이용택;오중교
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.219-228
    • /
    • 2003
  • This study was carried to investigate the effect of humic acid and kaloin which cause the turbidity and organic substance component for optimization of drinking water treatment process using the membrane separation. Also we were ovserved the optimum operating condition which flux was stabilized, while specific resistance value in membrane was minimized. As the result, the membrane separation was operated at low specific resistance value with the increase of the pressure. And then, cake load decreased by high velocity with the increase of the linear velocity, and the tendency in which specific resistance value and flux increased. Therefore, we confirmed the optimum operating condition as pressure $2.0 kgf/cm^2,$ 0.92 m/sec linear velocity.

Characterization of the Morphology and Corrosion Resistance in Electroless Ni-P-PTFE Composite Coating Prepared by Different pH Value (pH에 따른 무전해Ni-P-PTFE 복합도금의 표면형상 및 내식성에 대한 특성 연구)

  • Byoun, Young-Min;Seo, Sun-Kyo;Yoon, Jin-doo;Ryu, Chanh-Hwan;Na, Sang-Jo;Hwang, Hwan-il
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.156-162
    • /
    • 2019
  • Electroless Ni-P coatings are widely used in the chemical, mechanical, and electronic industries because of their excellent wear and abrasion resistance. In this study, The influence of pH values on properties of Ni-P-PTFE composite coatings was investigated. To improve mold lubrication, Ni-P-PTFE composite coatings at different pH value were studied. The morphology and phase structure of Ni-P-PTFE composite coatings were analyzed by scanning electron microscopy(SEM) and X-ray diffractometry(XRD). The result showed that Ni-P-PTFE composite coating is composed of Ni, P and PTFE. It exhibits an amorphous structure and good Corrosion Resistance to the substrate. Ni-P-PTFE composite coatings have higher open circuit potential than that of the substrate, which obtained at pH value of 5.0 optimal integrated properties.

Comparison of Predictive Value of Obesity and Lipid Related Variables for Metabolic Syndrome and Insulin Resistance in Obese Adults

  • Shin, Kyung A
    • Biomedical Science Letters
    • /
    • v.25 no.3
    • /
    • pp.256-266
    • /
    • 2019
  • In this study, obese adults were compared for their ability to predict obesity and lipid related variables and their optimal cutoff values to predict metabolic syndrome and insulin resistance. In this study, 9,256 adults aged 20 years or older and less than 80 years old, who were in the Gyeonggi region from January 2014 to December 2016 and who were examined at a general hospital, were enrolled. The diagnostic criteria for obesity were WHO (World Health Organization), and BMI $25kg/m^2$ or more presented in the Asia-Pacific region. Metabolic syndrome was diagnosed based on the criteria of American Heart Association / National Heart, Lung, and Blood Institute (AHA / NHLBI). According to the results of receiver operating characteristic curve (ROC) analysis, Triglyceride / HDL-cholesterol (TG / HDL-C), Triglyceride and Glucose (TyG) index, lipid accumulation product (LAP) and visceral adiposity index (VAI) showed high predictive power for diagnosing metabolic syndrome. The diagnostic accuracy of LAP (AUC: 0.854) for males and VAI (0.888) for females was the highest. The optimal cutoff value of LAP was 42.71 for male and 35.44 for female, and the cutoff value of VAI was 1.92 for male and 2.15 for female. In addition, WHtR (waist to height ratio), TyG index, and LAP were used as predictors of insulin resistance in obese adults. Therefore, LAP and VAI were superior to other indicators in predicting metabolic syndrome in obese adults.

Shear Resistance Capacity Length of Traditional Wooden Frame's Wall divided into Small Frame (세부목골조로 구성된 전통목골조 벽체 전단저항능력)

  • Hwang, Jong-Kook;Kwon, Yang-Hee;Bae, Dong-Hun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.11-18
    • /
    • 2019
  • The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.