• Title/Summary/Keyword: Resistance value

Search Result 2,569, Processing Time 0.031 seconds

Development and Structural Design of Textile Touch Sensor Easily Implemented (구현방식이 용이한 텍스타일 터치센서 개발 및 구조적 설계)

  • Kim, Ji-seon;Park, Jinhee;Kim, Jooyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.1
    • /
    • pp.168-179
    • /
    • 2021
  • This study presents and develops a textile type touch sensor structural design that is easy to implement. First, the design of the touch sensor circuit finds the size of the switch with the easiest finger contact and selects a structure with a long circuit with the lowest resistance value. An experiment is performed on a change in an electrostatic capacitance value that accompanies the distance on the electrode and the magnitude of the electrode area of the structure; however, the structure having the distance on the electrode and the large electrode area shows the best resistance change. The laundry assessment was conducted three times at a time and ten times at a time with an average standard deviation less than one ohm, with little change in resistance. Consequently, there were no problems with durability and performance for laundry. Finally, in the bending evaluation, the difference in resistance can be seen between 1-2 ohms and was developed as a smart wearable in the future; in addition, there was no problem as a difference in resistance can be seen between 1 and 2 ohms.

On-Site Calibration Technology of Burden using Voltage Transformer Comparator (전압변성기 비교기를 이용한 부담의 현장교정 기술)

  • Jung, Jae Kap;Kwon, Sung Won;Park, Young Tae;Kim, Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.503-507
    • /
    • 2005
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of VT burden used. Thus, precise measurement of burden is very important for the evaluation of VT. A method of evaluation for VT burden has been developed by employing the portable decade resistor, with AC-DC resistance difference less than 10-3. The burden value(value and power factor) can be obtained by conductance and susceptance, obtained by measuring the change of ratio error and phase angle error caused by the resistance change of decade resistor. The burden value and power factor obtained by the method are consistent with those obtained using power analyzer within corresponding uncertainties.

A Study on Conquest Plans of the Barrier and Resistance in Innovation Management (혁신관리에 있어서 장애와 저항의 극복방안)

  • Lee, Seung-Hui;No, Gyu-Seong
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.13-28
    • /
    • 2005
  • The purpose of this study is to explore conquest plans of the barrier and resistance in innovation management. This paper focuses to understand the model of innovation that reflects adoption process stages and identify the factors that drive the resistance of consumers. Whenever organizations try to plan and implement some kind of innovation in organizations, they confront resistance in many ways. By understanding innovation resistance, organizations can not only design better innovations but can develop strategies to reduce resistance. Thus they accelerate innovation. Understanding the factors that drive the innovation resistance has important implications for both theoretical development and managerial action. These results indicate that people resist innovation strongly when it betrays their value, needs and beliefs or when they felt the pressure on self-conviction and mental risk, loss, and lack of knowledge.

  • PDF

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF

Primary Resistance Compensation of Linear Induction Motor Using Thermocouple (Thermocouple을 이용한 선형 유도전동기의 1차측 저항 보상)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.742-747
    • /
    • 2006
  • This paper describes online stator-resistance estimation of a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC), where the resistance value is derived from stator-winding temperature estimation using thermocouple. In this paper, corrected stator resistance has an error in actuality measurement resistance. So compensation coefficient $\kappa$ which is decided through comparison and verifying several times relation of calculated resistance and measured motor line-line resistance. The stator-winding temperature information can also be used for monitoring, protection, and fault-tolerant control of the machine. Also, this paper reports the LIM's responses of the flux measured by the proposed stator resistance compensation algorithm.

  • PDF

A Study of Change in Current Resistance Value of Electric Motor Requied for Ground Dilling (지반굴착에 소요되는 전기식모터의 전류저항값 변화에 관한 연구)

  • Seo, Dong-Nam;Jeong, Sang-Hoon;Lee, Sang-Hyun;Shin, Jin-Seob;Choi, Sang-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.385-386
    • /
    • 2023
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

  • PDF

A Study on the Factors Influencing on the Salesperson's Resistance to SFA (영업사원의 SFA(영업자동화시스템)에 대한 저항에 영향을 미치는 요인들에 대한 연구)

  • Park, Chan Wook;Li, Liang;Cho, Ara
    • Journal of Information Technology Services
    • /
    • v.15 no.3
    • /
    • pp.15-31
    • /
    • 2016
  • Sales Force Automation (SFA) is a strategic information system and one of the components of operational CRM system. SFA supports salespeople's activities such as selection of potential customers, creative value proposition, after-sales services, etc. SFA is increasingly used in many companies because it has the advantages to raise the salespeople's productivity by developing forecasting ability, value proposition ability, after sales service ability etc. Many researches have shown that implementation of SFA leads to the increase of salepeople performance, organizational performance, and quality of customer relationship. However, Some prior studies have discussed on the SFA implementation failure and pointed out that one of important causes of this failure is salespeople's resistance to SFA. Although many researches explain SFA acceptance phenomenon using Technology Acceptance Model (TAM) and Theory of Planned Behavior (TPB), these researches didn't deeply investigate the salespeople's resistance to SFA. Therefore, this study focuses on the factors influencing salespeople's resistance to SFA and the relationships among these factors. This study identified three factors (salespeople's perceived loss of power, perceived loss of autonomy, and perceived time and effort waste) influencing salespeople's resistance to SFA. The hypotheses testing results showed that salespeople's perceived loss of power and perceived time and effort waste significantly increased salespeople's resistance to SFA. And salespeople's perceived loss of power plays a mediating role between perceived loss of autonomy/perceived time and effort waste and salespeople's resistance to SFA. At the end of the paper, theoretical and managerial implications of this study and the limitations and future research directions are discussed.

Human Chorionic Gonadotropin (hCG) Regression Curve for Predicting Response to EMA/CO (Etoposide, Methotrexate, Actinomycin D, Cyclophosphamide and Vincristine) Regimen in Gestational Trophoblastic Neoplasia

  • Rattanaburi, Athithan;Boonyapipat, Sathana;Supasinth, Yuthasak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5037-5041
    • /
    • 2015
  • Background: An hCG regression curve has been used to predict the natural history and response to chemotherapy in gestational trophoblastic disease. We constructed hCG regression curves in high-risk gestational trophoblastic neoplasia (GTN) treated with EMA/CO and identified an optimal hCG level to detect EMA/CO resistance in GTN. Materials and Methods: Eighty-one women with GTN treated with EMA/CO were classified as primary high-risk GTN (n = 65) and single agent-resistance GTN (n = 16). The hCG levels prior to each course of chemotherapy were plotted in the 10th, 50th, and 90th percentiles to construct the hCG regression curves. Diagnostic performance was evaluated for an optimal cut-off value. Results: The median hCG levels were 264,482 mIU/mL mIU/mL and 495.5 mIU/mL mIU/mL for primary high-risk GTN and single agent-resistance GTN, respectively. The 50th percentile of the hCG level in primary high-risk GTN and single agent-resistance turned to normal before the 4th and the 2nd course of chemotherapy, respectively. The 90th percentile of the hCG level in primary high-risk GTN and single agent-resistance turned to normal before the 9th and the 2nd course of chemotherapy, respectively. The hCG level of ${\geq}118.6mIU/mL$ mIU/mL at the 5thcourse of EMA/CO predicted the EMA/CO resistance in primary high-risk GTN patients with a sensitivity of 85.7% and a specificity of 100%. Conclusion: EMA/CO resistance in primary high-risk GTN can be predicted by using an hCG regression curve in combination with the cut-off value of 118.6 mIU/mL at the 5thcourse of chemotherapy.

Evaluation of the Characteristics of the Aluminum Alloy Casting Material by Heat Treatment (AC8A 알루미늄합금 주조재의 열처리에 의한 특성 평가)

  • Lee, Syung Yul;Park, Dong Hyun;Won, Jong Pil;Kim, Yun Hae;Lee, Myung Hoon;Moon, Kyung Man;Jeong, Jae Hyun
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.280-285
    • /
    • 2012
  • Aluminum is on active metal, but it is well known that its oxide film plays a role as protective barrier which is comparatively stable in air and neutral aqueous solution. Thus, aluminum alloys have been widely applied in architectural trim, cold & hot-water storage vessels and piping etc., furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston because of its properties of temperature and wear resistance. In recent years, the oil price is getting higher and higher, thus the using of low quality oil has been significantly increased in engines of ship and vehicle. Therefore it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and prolong its lifetime. In this study, the effect of solution and tempering heat treatment to corrosion and wear resistance is investigated with electrochemical method and measurement of hardness. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment and exhibited the highest value of hardness with tempering heat treatment temperature at $190^{\circ}C$ for 24hrs. Furthermore, corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. As a result, it is suggested that the optimum heat treatment to improve both corrosion and wear resistance is tempering heat treatment temperature at $190^{\circ}C$ for 16hrs.

Contact resistance increment of no-insulation REBCO magnet during a quench

  • Im, Chaemin;Cho, Mincheol;Bang, Jeseok;Kim, Jaemin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.31-35
    • /
    • 2019
  • The lumped-parameter circuit model for a no- insulation (NI) high temperature superconductor (HTS) magnet has been well understood after many experimental and analytic studies over a decade. It successfully explains the non-linear charging behaviors of NI magnets. Yet, recently, multiple groups reported that the post-quench electromechanical behaviors of an NI HTS magnet may not be well explained by the lumped circuit model. The characteristic resistance of an NI magnet is one of the key parameters to characterize the so-called "NI behaviors" of an NI magnet and recently a few groups reported a potential that the characteristic resistance of an NI magnet may substantially vary during a quench. This paper deals with this issue, the increment of contact resistance of the no-insulation (NI) REBCO magnet during a quench and its impact on the post-quench behaviors. A 7 T 78 mm NI REBCO magnet that was previously built by the MIT Francis Bitter Magnet Laboratory was chosen for our simulation to investigate the increment of contact resistance to better duplicate the post-quench coil voltages in the simulation. The simulation results showed that using the contact resistance value measured in the liquid nitrogen test, the magnitude of the current through the coil must be much greater than the critical current. This indicates that the value of the contact resistance should increase sharply after the quench occurs, depending on the lumped circuit model.