• 제목/요약/키워드: Resistance in series model

검색결과 184건 처리시간 0.032초

손상역학에 근거한 원자력 재료의 평면크기 영향 분석 (Assessment of In-plane Size Effect of Nuclear Materials Based on Damage Mechanics)

  • 장윤석;이태린;최재붕;석창성;김영진
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.393-401
    • /
    • 2006
  • The influences of stress triaxiality on ductile fracture have been investigated for various specimens and structures. With respect to a transferability issue, recently, the interests on local approaches reflecting micromechanical specifics are increased again due to rapid progress of computational environments. In this paper, the applicability of the local approaches has been examined through a series of finite element analyses incorporating modified GTN and Rousselier models as well as fracture toughness tests. The ductile crack growth of nuclear carbon steels is assessed to verify the transferability among compact tension (CT) specimens with different in-plane size. At first, the basic material constants were calibrated for standard CT specimens and used to predict fracture resistance (J-R) curves of larger CT specimens. Then, the in-plane size effects were examined by comparing the numerically estimated J-R curves with the experimentally determined ones. The assessment results showed that the in-plane size effect should be considered for realistic engineering application and the damage models might be used as useful tool for ductile fracture evaluation.

수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구 (THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS)

  • 손병섭;장익태;허성주;곽재영
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

초전도 한류기 투입저항 변화에 따른 여자돌입전류 저감률 분석 (Analysis of Inrush Current Reduction Rate According to Insertion Resistance of the Superconducting Fault Current Limiter)

  • 박세호;서훈철;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.257-258
    • /
    • 2008
  • The inrush current of a transformer is a high-magnitude and harmonic-rich current generated when the transformer core is driven into saturation during energizing. The inrush current usually leads to undesirable effects, for example potential damage to the transformer, misoperation of a protective relay, and power quality deterioration in the distribution power system. Inrush current reduction is therefore important for power system operation. In this paper, to reduce the inrush current, the insertion resistance of the Superconducting Fault Current Limiter (SFCL) that is connected in series with the transformer in the distribution system is used. This paper implements the SFCL by using the Electromagnetic Transient Program-Restructured Version (EMTP-RV) to model the SFCL in the distribution system. The simulation results show the beneficial effects of the SFCL for reduction of the inrush current.

  • PDF

Solid State Transformer를 위한 양방향 Dual Active Bridge DC-DC 컨버터의 설계 기법 (Practical Design Methodology of Dual Active Bridge Converter as Isolated Bi-directional DC-DC Converter for Solid State Transformer)

  • 최현준;이원빈;정지훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.102-108
    • /
    • 2017
  • Proper design guides are proposed for a practical dual-active bridge (DAB) converter based on the mathematical model on the steady state. The DAB converter is popular in bidirectional application due to its zero-voltage capability and easy bidirectional operation for seamless control, high efficiency, and performance. Some design considerations are taken to overcome the limitation of the DAB converter. The practical design methodology of power stage is discussed to minimize the conduction and switching losses of the DAB converter. Small-signal model and frequency response are derived and analyzed based on the generalized average method, which considers equivalent series resistance, to improve the dynamics, stability, and reliability with voltage regulation of the practical DAB converter. The design of closed-loop control is discussed by the derived small-signal model to obtain the pertinent gain and phase margin in steady-state operation. Experimental results of a 3.3 kW prototype of DAB converter demonstrate the validity and effectiveness of the proposed methods.

수평집적형 광전자집적회로를 위한 InP/InGaAs PIN 광다이오드의 설계 및 제작 (Design and Fabrication of InP/InGaAs PIN Photodiode for Horizontally Integrated OEIC's)

  • 여주천;김성준
    • 전자공학회논문지A
    • /
    • 제29A권4호
    • /
    • pp.38-48
    • /
    • 1992
  • OEIC(Optoelectronic Integrated Circuit)'s can be integrated horizontally or vertically. Horizontal integration approach is, however, more immune to parasitic and more universally applicable. In this paper, a structural modeling, fabrication and characterization of PIN photodiodes which can be used in the horizontal integration are performed. For device modeling, we build a transmission line model from 2-D device simulation, from which lumped model parameters are extracted. The speed limits of the PIN photodiodes can also be calculated under various structural conditions from the model. Thus optimum design of horizontally integrated PIN photodiodes for high speed operation are possible. Such InGaAs/InP PIN photodiodes for long-wavelength communications are fabricated using pit etch, epi growth, planarization, diffusion and metallization processes. Planarization process using both RIE and wet etching and diffusion process using evaporated Zn$_{3}P_{2}$ film are developed. Characterization of the fabricated devices is performed through C-V and I-V measurements. At a reserve bias of 10V, the dark current is less than 5nA and capacitance is about 0.4pF. The calculated bandwidth using the measured series resistance and capacitance is about 4.23GHz.

  • PDF

$Alq_3$에 기초한 유기 발광 소자에서 전기전도특성과 등가회로분석 (Electrical Conduction Mechanism and Equivalent Circuit Analysis in $Alq_3$ based Organic Light Emitting Diode)

  • 정동회;신철기;이동규;이준웅;이석재;이원재;장경욱;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.103-106
    • /
    • 2004
  • We have studied a conduction mechanism and equivalent circuit analysis in $Alq_3$ based Organic Light Emitting Diode. The conduction mechanism in organic light emitting diode can be classified into three regions; ohmic region, space-charge-limited current (SCLC) region and trap-charge-limited current (TCLC) region depending on the region of applied voltage. Equivalent circuit model of organic light emitting diode can be established using a parallel combination of resistance $R_p$ and capacitance $C_p$ with a small series resistance $R_s$.

  • PDF

난류가열 쎄타핀치의 고전압 펄스 발생에 관한 연구 (Study on the High Voltage Pulse Profile Characteristics of a Turbulently Heated Theta Pinch)

  • 강형보;정운관;육종철
    • 대한전기학회논문지
    • /
    • 제33권11호
    • /
    • pp.456-463
    • /
    • 1984
  • The fast-rising high-voltage pulse generation circuit system of a theta pinch is both theoretically and experimentally investigated. The idealized model of this circuit system is a hybrid circuit system composed of three parts: a lumped circuit part being consisted of a capacitor bank and a spark switch connected in series, another lumped circuit part being consisted of the Blumlein transmission line, whose end load is the pinch coil. the voltage difference between two ends of the pinch coil is formulated by analyzing this hybrid circuit system by means of the law of the signal propagation in the transmission line and Kirchhoff's laws. The expedient numerical method for computer calculation is developed to generate the pulse profile of the voltage difference across the pinch coil. The period of the experimentally measured main pulse is a fourth of the theoretical one neglecting the resistance of the pinch coil. We attribute this discrepancy to the modelling in the theoretical calculation that hte resistance and inductance of the spark switch and capacitor bank are assumed to be constant through discharge. Therefore, we can see that the rise time of the imploding magnetic-field pulse is mainly dependent on the spark switch and capacitor bank.

  • PDF

Current-in-plane Tunneling Measurement through Patterned Contacts on Top Surfaces of Magnetic Tunnel Junctions

  • Lee, Ching-Ming;Ye, Lin-Xiu;Lee, Jia-Mou;Lin, Yu-Cyun;Huang, Chao-Yuan;Wu, J.C.;Tsunoda, Masakiyo;Takahashi, Migaku;Wu, Te-Ho
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.169-172
    • /
    • 2011
  • This study reports an alternative method for measuring the magnetoresistance of unpatterned magnetic tunnel junctions similar to the current-in-plane tunneling (CIPT) method. Instead of using microprobes, a series of point contacts with different spacings are coated on the top surface of the junctions and R-H loops at various spacings are then measured by the usual four-point probe method. The values of magnetoresistance and resistance-area products can be obtained by fitting the measured data to the CIPT theoretical model. The test results of two types of junctions were highly similar to those obtained from standard CIPT tools. The proposed method may help to accelerate the process for evaluating the quality of magnetic tunnel junctions when commercial CIPT tools are not accessible.

Exploring the effects of speed and scale on a ship's form factor using CFD

  • Terziev, Momchil;Tezdogan, Tahsin;Demirel, Yigit Kemal;Villa, Diego;Mizzi, Simon;Incecik, Atilla
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.147-162
    • /
    • 2021
  • The problem of predicting a ship's form factor and associated scale effects has been subject to many investigations in recent years. In this study, an attempt is made to investigate whether the form factor is influenced by a change in the ship's speed by numerically modelling a geosim series of the KCS hull form by means of a RANS solver. The turbulence dependence of the problem is also studied by altering the closure model among three widely used approaches (the k-𝜔, k-𝜔 SST, and k-𝜀 models). The results show that at very low speeds (Froude numbers in the range of 0.02-0.06) the numerical model predicts changes in the form factor of a ship between 10% and 20%, depending on the turbulence model and scale factor choices. As the speed is increased further, the form factor exhibits little change, usually in the range of 1% or less. Simulations where the Reynolds number is changed by approximately two orders of magnitude, achieved by altering the value of viscosity, confirmed that the form factor can be considered Froude-dependent only for low speeds, predicting essentially identical values when high speed cases are considered.

Numerical study on fire resistance of cyclically-damaged steel-concrete composite beam-to-column joints

  • Ye, Zhongnan;Heidarpour, Amin;Jiang, Shouchao;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • 제43권5호
    • /
    • pp.673-688
    • /
    • 2022
  • Post-earthquake fire is a major threat since most structures are designed allowing some damage during strong earthquakes, which will expose a more vulnerable structure to post-earthquake fire compared to an intact structure. A series of experimental research on steel-concrete composite beam-to-column joints subjected to fire after cyclic loading has been carried out and a clear reduction of fire resistance due to the partial damage caused by cyclic loading was observed. In this paper, by using ABAQUS a robust finite element model is developed for exploring the performance of steel-concrete composite joints in post-earthquake fire scenarios. After validation of these models with the previously conducted experimental results, a comprehensive numerical analysis is performed, allowing influential parameters affecting the post-earthquake fire behavior of the steel-concrete composite joints to be identified. Specifically, the level of pre-damage induced by cyclic loading is regraded to deteriorate mechanical and thermal properties of concrete, material properties of steel, and thickness of the fire protection layer. It is found that the ultimate temperature of the joint is affected by the load ratio while fire-resistant duration is relevant to the heating rate, both of which change due to the damage induced by the cyclic loading.