• 제목/요약/키워드: Resistance coefficient

검색결과 1,556건 처리시간 0.028초

감압용 배수탱크내의 분기형 증기분사기의 유동특성에 관한 연구 (A Study on Flow Characteristics of Branch Type Sparger in Drain Tank for Depressurization)

  • 김광추;박만흥;박경석
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.356-367
    • /
    • 2001
  • A numerical analysis on branch type sparger in drain tank for depressurization is performed to investigate the flow characteristics due to the change of design factor. As the result of this study, sparger\\`s flow resistance coefficient(K) is 3.53 at the present design condition when engineering margin for surface roughness is considered as 20%, and flow ratio into branch pipe ($Q_s/Q_i$) is 0.41. The correlation for calculating flow resistance coefficients as design factor is presented. Flow resistance coefficient is increased as section area ratio of branch pipe for main pipe and outlet nozzle diameter of main pipe decreasing, but the effects of branch angle and inlet flow rate of main pipe are small. As the change rate of ($Q_s/Q_i$)becomes larger, the change rate of flow resistance coefficient increases. The rate of pressure loss has the largest change as section area ratio changing. The condition of maximum flow resistance in sparger is when the outlet nozzle diameter ratio of main pipe ($D_e/D_i$) is 0.167, the section area ratio ($A_s/A_i$) is 0.1 and the branch angle ($\alpha$) is 55^{\circ}$.

  • PDF

재하시험에 의한 PHC 매입말뚝의 저항계수 산정 II (Estimation of resistance coefficient of PHC bored pile by Load Test II)

  • 박종배;박용부;권영환
    • 토지주택연구
    • /
    • 제9권3호
    • /
    • pp.1-8
    • /
    • 2018
  • 유럽과 미국에서는 말뚝기초 설계에 한계상태설계법 사용이 거의 정착되었으며, 세계적 추세에 따라 국내에서도 국토해양부가 한계상태설계법에 기반한 교량하부기초 설계기준을 제정하였지만, 국내 말뚝공법 및 지반조건에 대한 저항계수 연구가 부족하여 당장 설계에 반영하기에는 어려운 여건이었다. 이에 본 연구에서는 국내에서 많이 사용되고 있는 PHC 매입말뚝의 저항계수를 구하기 위하여 LH설계기준과 도로교설계기준 방법으로 산정한 지지력과 LH 현장에서 실시한 정재하시험(21회)과 동재하시험(EOID 21회, Restrike 21회) 결과를 신뢰성분석을 실시하였으며, 선행 논문(재하시험에 의한 PHC 매입말뚝의 저항계수 산정)에서 수행한 결과보다 2배 이상 많은 데이터를 추가하여 분석하였다. 그 결과 정재하지지력(극한)으로 구한 저항계수는 설계식 및 목표신뢰도지수에 따라 0.64~0.83, 동재하지지력(극한)으로 구한 저항계수는 0.42~0.55로 나와 정재하지지력(극한)으로 구한 저항계수보다 약 33% 작게 나타났다. 반면 수정동재하지지력(EOID의 극한선단지지력 + Restrike의 극한주면지지력)으로 구한 저항계수는 0.55~0.71로 나와 정재하지지력(극한)으로 구한 저항계수와 비교 시 그 차이가 약 14%로 줄어들었다. 데이터 추가에 의해 저항계수를 산정한 결과 이전 저항계수와 같거나 0.04정도 증가하여 데이터가 2배 이상 추가되어도 저항계수가 의미 있을 정도로 크게 변하지 않은 것으로 나타났다. 결론적으로 본 연구에서 정재하 및 동재하시험으로 산정한 전체 저항계수는 전반적으로 도로교설계기준(2015)에서 제시한 저항계수 0.3보다 커서 경제적인 설계가 가능한 것으로 나타났다.

현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정 (The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF

Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향 (Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator)

  • 박용석;성홍석;성동민;서정세
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.

대형 캐비테이션터널에서 몰수체 저항시험 및 위벽효과 수정 기법 연구 (Study of the Resistance Test and Wall Blockage Correction Method for the Submerged Body in LCT)

  • 안종우;설한신;박영하;김기섭
    • 대한조선학회논문집
    • /
    • 제57권3호
    • /
    • pp.133-139
    • /
    • 2020
  • In order to study the resistance test technique for the submerged body in Large Cavitation Tunnel (LCT), DARPA Suboff, submarine model publicly available was manufactured. DTRC released the resistance test data of DARPA Suboff conducted at ship speeds up to 18.0 knots in high-speed towing tank in 1990. As LCT is considered restricted waterways with walls, the resistance test results must be corrected with three wall blockage effects called buoyancy effect, solid blockage effect and wake blockage effect. Before correction, the resistance of LCT was 16~20 % higher than that of DTRC. After correction, the resistance and the resistance coefficients were compared with those of DTRC. The corrected resistance of LCT shows good agreement with that of DTRC. The residual resistance coefficient shows the difference according to the calculation method of buoyancy and frictional resistance coefficient. This paper suggests the best way for the calculation of residual resistance coefficient, On the basis of the present study, it is thought that the operating conditions for the propeller cavitation and noise tests can be drawn through LCT tests.

혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구 (Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures)

  • 유재강;김동석;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3~4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구 (Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures)

  • 유재강;김동석;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzaolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3∼4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

점도변화에 따른 바닥 오염물질의 미끄러짐 저항 특성 (Slip Resistance of Contaminants on the Floor for Variation of Viscosity)

  • 박재석;오환섭
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.185-189
    • /
    • 2012
  • While there is no standards on slip risk for contaminants on surface, glycerol is described in standard contaminant for measuring coefficient of friction(COF) and slip resistance such as ISO 13287. But that is just used to measure the slip resistance of surface materials and shoes not to evaluate the contaminant materials. Therefore the objective of this study was to find out the relationship between standard contaminant and the contaminants used usually at the workplaces. For this, some measurement criteria were acquired from the analysis based on biomechanics and kinetics of human gait during slips. The slip resistance according to viscosity of the contaminants was measured applying the criteria and slip probability was determined by the gait analysis. Some factors which should be considered when measuring the slip resistance were identified. The velocity, acceleration, contact time and contact pressure should be 1 m/sec, 10 $m/sec^2$, 350 kPa and less than 0.5sec respectively. The variation of viscosity according to temperature for working oils was different from that of standard contaminant. The static coefficient of friction (SCOF) of working oils was almost 0.5 times as large as the SCOF of standard contaminant. So it was assumed to be difficult to compare the contaminants at the workplaces with the glycerol as a standard contaminant for estimating the slip risk.

2자유도 진동계의 운동정보 전달에 관한 연구;경계면열저항 (A Study on the Transfer of the Oscillator's Motion Information with 2 Degrees of Freedom;Thermal Boundary Resistance)

  • 최순호;최현규;김창복;김경근;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1102-1107
    • /
    • 2005
  • The analysis of the thermal boundary resistance is very important in the both cases of microscale and macroscale systems because it plays a role of thermal barrier against a heat flow. Especially, since fairly large heat energy is generated in microscale or nanoscale systems with electronic chips, the thermal boundary resistance is a key factor to guarantee the performance of those devices. In this study, the transfer of the oscillator's motion information with 2 degrees of freedom is investigated for clarifying the mechanism of a thermal boundary resistance. We found that the transfer of the oscillator's motion information is defined as a cross-correlation coefficient and the magnitude of it determines the temperature jump over a solid interface. That is, the temperature jump over an interface increases as the magnitude of a cross-correlation coefficient decreases and vice versa.

  • PDF

높은 열저항 계수를 가지는 비냉각형 적외선 열영상 이미지 센서용 MDTF(Metal-dielectric Thin Film)에 관한 연구 (A Study on the MDTF for Uncooled Infrared Ray Thermal Image Sensors with High Thermal Coefficient of Resistance)

  • 정은식;정세진;강이구;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제25권5호
    • /
    • pp.366-371
    • /
    • 2012
  • In this paper, fabricated by MEMS uncooled micro-bolometer detector for the study in the infrared sensitivity enhancement. Absorption layer SiOx-Metal series MDTF (metal-dielectric thin film) by high absorption rate and has a high thermal coefficient of resistance, low noise characteristics were implemented. Then MDTF were made in a vacuum deposition method. And MDTF for the analysis of the physical properties of silicon wafers were fabricated, TCR (temperature coefficient of resistance) value was made in order to measure the glass wafer and FT-IR (Fourier Transform Infrared spectroscopy) values were made in order to measure the germanium window. The analyzed results of MDTF -3 [%/K] has more characteristics of the TCR. And 8~12 um wavelength region close to 70% in the absorption characteristic.