• 제목/요약/키워드: Resistance change

검색결과 2,413건 처리시간 0.031초

연성 의치상 이장재의 염색 저항성에 관한 연구 (STAINING RESISTANCE OF THE SOFT DENTURE LINERS)

  • 김광준;조혜원;진태호
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.492-499
    • /
    • 2000
  • This study was investigated to compare the staining resistance of soft denture liners. Specimens were made of Coe-soft, Coe-comfort, Soft-liner, Visco-gel, and were stored in 1% methyleneblue solution for 24 hours. The amounts of color change before and after treatment with mono-poly and thermocycling were measured by colorimeter(TC-6FX, Tokyo Denshoku Co. Ltd, Japan) for evaluation of staining resistance. The following conclusions were drawn from this study. 1. The staining resistance of Visco-gel was increased, but there was no changes of staining resistance in Coe-soft, Coe-comfort, and Soft-liner after treatment with monopoly. 2. The staining resistance of the Coe-comfort was the least in all soft denture liners. 3. The staining resistance of Visco-gel and Soft-liner were decreased after thermocycling.

  • PDF

Novel GST/TiAlN 구조를 갖는 상변화 메모리 소자의 전기적 특성 (Electrical Properties of Phase Change Memory Device with Novel GST/TiAlN structure)

  • 이남열;최규정;윤성민;류상욱;박영삼;이승윤;유병곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.118-119
    • /
    • 2005
  • PRAM (Phase Change Random Access Memory) is well known to use reversible phase transition between amorphous (high resistance) and crystalline (low resistance) states of chalcogenide thin film by electrical Joule heating. In this paper, we introduce a stack-type PRAM device with a novel GST/TiAlN structures (GST and a heating layer of TiAlN), and report its electrical switching properties. XRD analysis result of GST thin film indicates that the crystallization of the GST film start at about $200^{\circ}C$. Electrical property results such as I-V & R-V show that the phase change switching operation between set and reset states is observed, as various input electrical sources are applied.

  • PDF

SABiT 공법적용 인쇄회로기판의 은 페이스트 범프 크기 및 제작 조건에 따른 전기 저항 특성 (Characterization of Electrical Resistance for SABiT Technology-Applied PCB : Dependence of Bump Size and Fabrication Condition)

  • 송철호;김영훈;이상민;목지수;양용석
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.298-302
    • /
    • 2010
  • We investigated the resistance change behavior of SABiT (Samsung Advanced Bump interconnection Technology) technology-applied PCB (Printed Circuit Board) with the various bump sizes and fabrication conditions. Many testing samples with different bump size, prepreg thickness, number of print on the formation of Ag paste bump, were made. The resistance of Ag paste bump itself was calculated from the Ag paste resistivity and bump size, measured by using 4-point probe method and FE-SEM (Field Emission Scanning Electron Microscope), respectively. The contact resistance between Ag paste bump and conducting Cu line were obtained by subtracting the Cu line and bump resistances from the measured total resistance. It was found that the contact resistance drastically changed with the variation of Ag paste bump size and the contact resistance had the largest influence on total resistance. We found that the bump size and contact resistance obeyed the power law relationship. The resistance of a circuit in PCB can be estimated from this kind of relationship as the bump size and fabrication technique vary.

YAG 상함량에 따른 YAS (Y2O3-Al2O3-SiO2)계 코팅층의 내플라즈마 특성 (Plasma Resistance of YAS (Y2O3-Al2O3-SiO2) Coating Layer with YAG Phase Contents)

  • 박의근;이현권
    • 한국재료학회지
    • /
    • 제30권11호
    • /
    • pp.621-626
    • /
    • 2020
  • This study is aimed at preparing and evaluating the plasma resistance of YAS (Y2O3-Al2O3-SiO2) coating layer with crystalline YAG phase contents. For this purpose, YAS frits with controlled phase contents are prepared and melt-coated on sintered Al2O3 ceramics. Then, the results of phase analysis of crystalline YAS coating layer are compared to that of YAS frits, and discussed with regard to the plasma resistance of the YAS coating layer. The phase contents of the YAS frit change in a manner different from that of the prepared YAS coating layer, presumably owing to the composition change of YAS frit during the melt-coating process. The plasma resistance of the YAS coating layer is shown to increase with the YAG phase contents in the coating layer. Comparing the weight loss of YAS coating layer with those of commercial Y2O3, Al2O3, and quartz ceramics, the plasma resistance of the prepared YAS coating layer is 8 times higher than that of quartz and 3 times higher than that of Al2O3; this layer shows 70 % of the resistance of Y2O3.

Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향 (Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator)

  • 박용석;성홍석;성동민;서정세
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.

녹용수침액(鹿茸水浸液)이 Mouse의 Stress 방어작용에 미치는 영향(影響) (Effect of the Antler (Deer Horn) Water Extract on the Stress Resistance in Mice)

  • 고건일
    • Journal of Pharmaceutical Investigation
    • /
    • 제11권2호
    • /
    • pp.11-15
    • /
    • 1981
  • Antler, deer horn, occupies a particular place in oriental folk medicine as so called tonic remedy. In order to study on the effects of Antler water extract on stress resistance in mice, quantitative response was measured for the change of spontaneous activity by chemical stress drugs in the control group or the Antler water extract pretreated group. Spontaneous activity in mice was measured by counting the number of interruptions of light. The results of experiment were summerized as follows; I) In case of administrating Antler water extract 10mg/kg, 20mg/kg, 50mg/kg, and 100mg/kg, no significant change was observed in spontaneous activity in comparison with the control group. II) In case of administrating Antler water extract for 5 days or 10 days, no significant change was observed in spontaneous activity by chemical stress drugs, caffein and chloropromazine, in comparison with the control group.

  • PDF

판형 상변화 물질 용기의 2상 열교환 현상 연구 (A Study on Two Phase Heat Exchange of Plate Type PCM Container)

  • 김석현;조성우;이채수
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.576-582
    • /
    • 1996
  • This work studies qualitative thermal characteristics of PCM cold storage medium container and its surrounding streams. Experimental parameters are initial PCM temperature and cold water flow rate. A mathematical modeling was establised to estimate temperature distribution and the cooling process. We found that the phase-change temperatures of PCM varies from 6 to $8^{\circ}C$ which is constant for other materials and that the dominant heat transfer resistance is that on the container side taking about 3/4 of the total resistance. The one dimensional mathematical model predicts experimental data quit well.

  • PDF

Sulfate Resistance of Cement Matrix Containing Limestone Powder

  • 문한영;정호섭;이승태;김종필
    • 콘크리트학회논문집
    • /
    • 제16권3호
    • /
    • pp.433-440
    • /
    • 2004
  • In order to improve the performance of concrete, generally, modern cements often incorporate several mineral admixtures. In this study, the experimental included the flow value, air content of mortar containing limestone powder and length change and compressive strength of mortar specimen immersed in sulfate solutions. From the experimental results, the limestone powder cement matrices improved the physical properties and sulfate resistance of cement matrices at $10\%$ replacement ratio of limestone powder. The $30\%$ replacement ratio of limestone powder was significantly deteriorated in sodium sulfate solution. Irrespective of fineness levels of limestone powder, length change and SDF of mortar specimens with only $10\%$ replacement was much superior to the other replacements.

Theoretical and experimental investigation of piezoresistivity of brass fiber reinforced concrete

  • Mugisha, Aurore;Teomete, Egemen
    • Computers and Concrete
    • /
    • 제23권6호
    • /
    • pp.399-408
    • /
    • 2019
  • Structural health monitoring is important for the safety of lives and asset management. In this study, numerical models were developed for the piezoresistive behavior of smart concrete based on finite element (FE) method. Finite element models were calibrated with experimental data collected from compression test. The compression test was performed on smart concrete cube specimens with 75 mm dimensions. Smart concrete was made of cement CEM II 42.5 R, silica fume, fine and coarse crushed limestone aggregates, brass fibers and plasticizer. During the compression test, electrical resistance change and compressive strain measurements were conducted simultaneously. Smart concrete had a strong linear relationship between strain and electrical resistance change due to its piezoresistive function. The piezoresistivity of the smart concrete was modeled by FE method. Twenty-noded solid brick elements were used to model the smart concrete specimens in the finite element platform of Ansys. The numerical results were determined for strain induced resistivity change. The electrical resistivity of simulated smart concrete decreased with applied strain, as found in experimental investigation. The numerical findings are in good agreement with the experimental results.