• 제목/요약/키워드: Resin simulated canal

검색결과 49건 처리시간 0.028초

학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교 (Comparison of screw-in effect of three NiTi file systems used by undergraduates)

  • 오승희;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.477-484
    • /
    • 2006
  • 학생들이 사용한 세 가지 NiTi file systems (ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$)을 사용하여 성형한 모형 근관의 apical terminus width를 비교하여 flute angle 및 pitch 혹은 radial land가 screw-in effect에 미치는 효과를 알아보고자 하였다. NiTi file의 사용 경험이 없는 부산대학교 치과대학 4학년 학생 50명이 세 종류의 NiTi file systems- Pro File$^{(R)}$ (Dentsply Maillefer, Ballaigues, Switzerland), K3$^{TM}$ (SybronEndo, Glendora, France), Hero Shaper$^{\circledR}$(Micromega, Besancon, France)-을 사용하여 각 system으로 하나의 근관씩, 모두 150 개의 레진 블락 근관모형 (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland)을 16 : 1 감속 handpiece를 장착한 electric motor (Tecnika ATR, Pistola, Italy)를 사용하여 300 rpm의 속도에서 torque는 30 (Tecnikamotor setting value)으로 성형하였다. 스캐너로 근관 성형 전 후 이미지를 채득하여 중첩한 후 근단부의 최종 폭경을 측정하였다. 통계분석은 one-way ANOVA와 95% 신뢰도의 Scheffe's multiple range test로 사후 검증하였다. ProFile$^{(R)}$의 근관 성형 후 근단부의 폭이 Hero Shaper$^{(R)}$ and K3$^{TM}$에 비해 통계학적으로 유의하게 작았다. 본 연구의 결과에서 근단부의 과도한 확대가 variable pitch와 helical angle를 가진active file에 비해 con-stant pitch와 helical angle을 가짐에도 불구하고 radial land를 가진passive file에서 적게 나타났다. 이 결과로 추정해 볼 때, variable pitch와 helical angle보다는 근본적으로 radial land가 screw-in effect의 예방에 더 큰 역할을 하는 것으로 추정될 수 있다 따라서 NiTi file의 사용 경험이 없는 초심자의 경우 근단부 폭경의 유지능력이 좋은 ProFile$^{(R)}$의 사용이 추천된다.

ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향 (EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION)

  • 서민철;전윤정;강인철;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.179-185
    • /
    • 2006
  • 본 연구는 엔진 구동형 Ni-Ti 파일인 $ProTaper^{TM}$를 이용하여 좁고 만곡된 근관 형태를 가지는 레진 모형상에서 회전 속도를 변화시켰을 때 근관 형태 변화에 대해 비교 분석하기 위해 시행되었다. 16 mm의 작업장 길이를 갖는 40개의 기성품 레진 블록을 엔진 구동형 Ni-Ti파일인 $ProTaper^{TM}$를 사용하여 회전 속도를 제외하고 제조자의 지시에 따라 크라운다운법으로 근관 성형하였다. 연구에 사용된 회전 속도는 250 rpm, 300 rpm, 350 rpm, 400 rpm이었으며, 근첨부 성형은 #25 파일 크기인 F2로 시행하였다. 근관 성형 전 후 이미지를 스캐너를 이용하여 얻었고, Photoshop 7.0 프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 치근단 쪽에서부터 1, 2, 3, 4, 5, 6, 7 및 8 mm부위의 내 외측 폭경 변화와 총폭경 및 근관의 중심축에 대한 근관 변위를 측정하였다. 각 부위에서 내 외측 폭경과 총폭경 및 근관의 중심축에 대한 근관 변위의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며, 각 기구간의 유의성 검정은 Scheffe's test로 사후 분석하였다. 또한 근관 성형 시간 기구의 변형과 파절 여부를 평가하여 다음과 같은 결과를 얻었다. 1. 본 실험에 이용된 회전속도로 근관성형시 회전 속도와 관계없이 치근첨에서 2 mm부위까지는 만곡의 외측으로 변위되고, $3{\sim}6mm$부위에서는 만곡의 내측으로 변위 되었다. 근첨에서 5 mm와 6 mm 부위를 제외하고 근관의 중심축에 대한 근관 변위는 통계적으로 유의성이 없었다. 2. 350 rpm, 400 rpm의 경우 250 rpm, 300 rpm에 비해 더 짧은 시간이 걸렸다. (p<0.01). 이상의 결과는 엔진 구동형 Ni-Ti파일인 $ProTaper^{TM}$를 사용하여 $250{\sim}400rpm$의 회전속도로 근관 성형시 근관 형태를 잘 유지하며, 빠른 회전 속도로 성형시 작업 시간도 줄일 수 있지만, 속도가 빨라지면 파일의 파절이 일어날 수 있으므로 주의해야 함을 시사한다.

엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향 (THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS)

  • 노형미;허복;김현철;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.486-492
    • /
    • 2005
  • 이 연구의 목적은 니켈-니타늄 파일의 삭제 성향과 엔진의 토크 조절 능력이 근관 성형에 미치는 영향을 평가하는 것이다 레진 모형 40개를 사용하였으며, Hero Shaper(R)와 Endo-Mate2을 이용한 HE군, Hero Shaper(R)와 Tecnika(R)를 이용한 HT군, Profile(R)과 Endo-Mate2(R)를 이용한 PE군, Profile(R)과 Tecnika(R)를 이용한 PT군으로 구분하여 근관성형 하였다. 각 군별 근관 성형 시간을 기록하였다. 근단공으로부터의 수직 이동 거리 1, 3 그리고 5mm 위치에서의 근관 삭제량, 중심이 동률을 산출하여 다음의 결론을 얻었다. 1. 근관 성형 시간은 HT군이 가장 빨랐다 (p<0.05). 2. 삭제량은 1mm지점에서 HE군이 PT군보다 컸고 (p<0.05), 3mm지점에서는 PT군이 다른 군들보다 작았다 (p<0.05). 5mm에서는 PE군이 PT군보다 컸다 (p<0.05). 3. 중심 이동률은 1mm 지점에서 HE군이 다른 군들보다 컸으며 (p<0.05), 5mm에서는 HT군이 PE군과 PT군보다 컸다 (p<0.05). 따라서 토크 조절이 되는 엔진을 사용하는 것이 근관의 변위를 적게 유발하고 과도한 삭제 량을 예방 할 수 있으며 근관 성형시간도 단축 할 수 있는 것으로 보이며 따라서 양호한 근관 성형 결과에 영향을 준다고 볼 수 있다.

학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교 (Relative efficacy of three Ni-Ti file systems used by undergraduates)

  • 김현철;박정길;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.38-48
    • /
    • 2005
  • 이 연구의 목적은 Ni-Ti file을 사용한 경험이 없는 학생들이 세 종류 Ni-Ti file systems을 사용하였을 때 근관 형성 효율을 비교하는 것이다. Ni-Ti file의 사용 경험이 없는 부산대학교 치과대학 4학년 학생 50명이 세 종류의 Ni-Ti file system - $ProFile^{(R)}$ (PF : Dentsply Maillefer, Ballaigues, Switzerland), manual $ProTaper^{(R)}$ (MPT: Dentsply Maillefer, Ballaigues, Switzerland), rotary $ProTaper^{(R)}$ (RPT: Dentsply Maillefer, Ballaigues, Switzerland) -을 사용하여 각 system으로 하나의 근관씩, 모두 150개의 레진 블락 근관모형(Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland)을 형성하였다. 근관형성에 사용된 file의 파절이나 변형 및 근관형성 후 형태의 이상을 조사하고, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1mm, 3mm, 그리고 5mm 높이에서의 삭제된 근관의 폭경, 근관의 변위량, 그리고 중심변위율 등을 산출하고 통계학적 비교 분석을 하였다. 그리고 세 가지 systems에 관한 학생들의 주관적인 선호도를 조사하였다. 그 결과 졸업을 앞둔 치과대학 재학생들도 특별한 문제점 없이 세 가지 Ni-Ti file systems을 사용한 근관형성이 가능함을 확인하였다. 세 실험군을 비교하였을 때, 양적인 삭제 능력은 두 $ProTaper^{(R)}$ systems (manual and rotary)이 $ProFile^{(R)}$에 비해 우세하였지만, 근관의 변위는 두 $ProTaper^{(R)}$ systems에서 더 많이 유발되었다. 근관 중심 이동률 등의 질적 평가를 포함하여 학생들의 선호도를 종합적으로 고려할 때, 삭제 능력에 있어서는 rotary $ProTaper^{(R)}$가 더 효율적이지만 안전성을 고려하면 $ProFile^{(R)}$도 추천된다. 정규 교육과정에서 Ni-Ti file systems의 도입을 위해서 초심자와 관련한 더 많은 연구가 진행되어야 하겠다.

학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교 (COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES)

  • 강문성;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 연구의 목적은 학생들이 사용한 세 가지 Ni-Ti파일의 성형효율을 비교하고, 각 파일의 사용 경험 유무에 따른 차이를 비교하여 치과대학생을 위한 교육에 적합한 종류를 선택하는데 도움을 얻고자하는 것이다. Ni-Ti파일 사용 경험이 없는 학생 50명과 Ni-Ti파일을 사용한 근관치료 경력이 2년 이상인 경험자 10명이 세 종류의 Ni-Ti file - $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$ -을 사용하여 180개의 근관 모형을 성형하였다. 근관성형 시간 및 기구 변형, 근관 이형성을 조사하고 성형 전후 상을 중첩하여 근관 삭제폭, 근관변위량과 중심변위율을 1, 3. 5 mm에서 분석하였다. 1. 근관 성형시간은 HS군이 가장 빨랐으며, 총 삭제 량은 모든 지점에서 K3군이 다른 군보다 컸다 (P<0.05) . 2. 세 군 모두 1, 3 mm에서 외측 변이를 보였고, 1 mm지점에서 PF군이 가장 안정적이었다 (P<0.05). 3. 중심변위율은 1, 3 mm에서 HS, PF군이 K3군보다 작았다. 5 mm지점에서는 PF군이 가장 작았고, PF군 3 mm에서 학생은 경험자보다 유의하게 작았다 (P<0.05).

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교 (Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file)

  • 임유경;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.385-396
    • /
    • 2007
  • 이 연구의 목적은 Mtwo 전동 파일의 사용에 있어서 제조사가 제안한 single length technique과 crown-down technique의 근관성형효율과 안전성을 비교하고 Mtwo 전동 파일의 변형된 사용방법을 제안하고자 하는 것이다. 기구의 종류와 사용방법에 따라 60개의 레진 블록 근관 모형 (Endo Training Bloc; Benstply Maillefer, Ballaigues, Switzerland)을 세 군으로 나누어 20개씩 표본을 성형하였다. MT군은 Mtwo 파일 (VDW, Munich, Germany)을 제조사의 추천방법인 single length technique으로, MC군은 Mtwo 파일을 crown-down technique으로 형성하였고, 대조군인 PT군은 ProTaper (Denstply Maillefer, Ballaigues, Switzerland)를 사용하였다. 모든 기구는 250 r.p.m., torque 2.2 N로 고정한 전동 모터 (X-smart; Denstply Maillefer, Ballaigues, Switzerland)로 사용하였다. 근관 성형 후, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1, 2, 3, 4, 5, 6, 7, 8 mm 높이에서의 중심변위율을 산출하였다. 순수 기구조작 시간 및 기구조작 동안의 binding빈도를 기록하였다. 근관 성형 후, 레진 블록의 무게 감소를 측정하였고 근관 성형에 사용된 파일의 파절이나 변형 및 근관 성형 후 형태의 이상을 조사하였다. 세 실험군의 측정 및 산출된 자료를 일원배치 분산분석 및 Duncan's Multiple Range Test로 사후 검정을 시행하여 비교하였으며, Fisher's exact test으로 근관의 이형성, 기구의 변형 그리고 기구 binding 등 발생 빈도를 유의 확률 95%에서 통계 검정하였다. 그 결과는 다음과 같다. 1. 근관의 만곡도 감소, 중심변위율, 레진 블록의 무게 감소, 기구 변형 등은 세 군간에 유의한 차이가 없었다 (p > 0.05). 2. 기구 조작 시간은 보면 MT군과 MC군이 PT군보다 짧았다 (p < 0.05). 3. Elbow는 MT군이 MC군에서 PT군보다 더 많이 형성되었다 (p < 0.05). Ledge는 세 군 모두에서 나타나지 않았다. 4. 파일 binding 횟수는 MC군이 가장 적고 PT군이 가장 많았다 (p < 0.05). 이상의 결과를 볼 때, Mtwo 전동 파일을 crown-down technique으로 사용하는 것이 single length technique과 유사한 성형 효율을 보이면서도 더 안전할 것으로 추정된다.

0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율 (Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments)

  • 이은아;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.79-85
    • /
    • 2005
  • 최근, 다양한 경사도의 니켈-티타늄 근관기구와 더불어 다양한 경사도의 gutta-percha cone이 소개되었다. 효율적인 근관 충전을 위해서는 짧은 시간에 적은 수의 기구 및 재료를 사용하여 균일한 gutta-percha로 근관을 충전할 필요가 있다. 본 연구에서는 0.06 경사도의 니켈-티타늄 전동화일로 형성된 만곡 근관에서 측방 가압법으로 근관충전시 비표준화 medium 크기 master gutta-percha cone의 충전효율을 ISO 표준화 규격의 master cone과 비교하여 평가하고자 하였다. 60개의 모형레진 만곡근관에서 0.06 경사도의 니켈-티타늄 전동화일 ($ProTaper^{TM},\;ProFile^{(R)}$, Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 근단부 근관이 30번 크기가 되게 crown-down법으로 근관을 형성하였다. 근관은 master gutta-percha cone, AH 26 실러 (Dentsply-DeTrey, Konstanz, Germany), 그리고 type A accessory cone (Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 측방가압법으로 충전하였으며, 이 때 사용된 master gutta-percha cone(Diadent, Chongju, Korea)과 Finger spreader(B type, Dentsply-Maillefer, Ballaigues, Switzerland)에 따라 임의로 15개씩 4개의 군으로 나누어 실험하였는데, St/SS 군에서는 ISO 표준화 규격의 30번 master cone과 스테인레스 스틸 finger spreader를, St/NT 군에서는 ISO 표준화 규격의 30번 master cone과 니켈-티타늄 finger spreader를, Non-St/SS 군에서는 비표준화 medium 규격 master cone과 스테인레스 스틸 spreader를, 그리고 Non-St/NT 군에서는 비표준화 medium 크기 master cone과 니켈-티타늄 finger spreader를 각각 사용하였다. 충전된 근관은 $37^{\circ}C$, 상대습도 $100\%$하에서 24시간 보관한 후, 치근단 1, 3및 5 mm수준에서 횡절단하여 입체현미경 하에서 관찰하고 컴퓨터에 저장한 다음, $Auto^{(R)}$CAD 2000 프로그램을 이용하여, 형성된 근관 및 gutta-percha 충전물의 외형을 추적하여 근관내 gutta-percha 면적비를 계산하였다. Gutta-percha 면적비의 결과치는 two-way ANOVA를, 그리고 accessory cone 수는 one-way ANOVA 및 Duncan's multiple range test를 이용하여 통계 분석하여 다음과 같은 결과를 얻었다. 스테인레스 스틸 finger spreader를 사용한 경우 및 니켈-티타늄 finger spreader를 사용한 경우 공히, 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해 유의하게 높은 gutta-percha 면적비를 나타내었다 (p < 0.01). 비표준화 medium크기 master cone 사용군에서는 표준화 규격의 master cone 사용군에 비해 유의하게 적은 수의 accessory cone이 사용되었다 (p < 0.01).