• 제목/요약/키워드: Residual water level

검색결과 163건 처리시간 0.024초

유리잔류염소와 모노클로라민에서의 생물막의 CLPP (CLPP of Biofilm in Free Chlorine Residual and Monochloramine)

  • 이동근
    • 한국환경보건학회지
    • /
    • 제31권2호
    • /
    • pp.147-151
    • /
    • 2005
  • The disinfection effect of free residual chlorine and monochloramine on biofilm communities were investigated by CLPP (community level physiology profile) using Biolog GN plates. Low concentration of disinfectant, $0.5\;mg/\iota$ free chlorine and $1.0\;mg/\iota$ monochloramine, stimulated the growth of bacteria rather than disinfection. Bacterial concentrations were decreased at more than $1.0\;mg/\iota$ of disinfectants. CLPP was different with the type and concentration of disinfectant and sampling time. Common and different carbon sources were actively used with similar bacterial concentration in free chlorine and monochloramine. This represents the differences of bacterial communities with tap water contact times and disinfectant.

영일만내의 유동과 수질특성에 관한 연구 (Study on Current and Water Quality Characteristics in Yongil Bay)

  • 김헌덕;김종인;류청로
    • 한국해양공학회지
    • /
    • 제15권4호
    • /
    • pp.28-37
    • /
    • 2001
  • The water quality in Yongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex. The study aims to simulate the current system that is necessary to build ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D model baroclinic model which considers tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most applicable on appearing the current system of the stratificated Yongil Bay difference of density. Form the results of simulation considered tidal current only, it can be clarified that the water body flows in the inner bay through the bottom layer and flows out the outer bay through the surface layer in Yongil Bay. And the fresh water from the Hyongsan river and the thermal discharge form POSCO have a little effect on the current system in Yongil Bay, but the diffusion of heat and salt has an important effect upon the formation of the density stratification of the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system in Yongil Bay.

  • PDF

영일만내의 유동과 수질특성에 관한 연구 (Study on Current and Water Quality Characteristics in Yongil Bay)

  • 김헌덕;김종인;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.246-252
    • /
    • 2000
  • The water quality in Yeongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex The study aims to simulate the current system that is necessary to built ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D baroclinic model considered tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most appliable on the Yongil Bay where current flows slowly and the flow direction is varied by depths. From the results of simulation considered tidal current only, It am be clearly said the water in Yongil Bay flows in through the surface layer and flows out through the bottom layer. And the fresh water from the Hyongsan river and the heated discharge from POSCO have little effect on the current structure in Yonggil Bay, but have and important effect upon the density structure by diffusion of heat and salt. And the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system.

  • PDF

Caffeine과 Carbamazepine: 낙동강 수계에서의 검출 및 정수처리 공정에서의 거동 (Caffeine and Carbamazepine: Detection in Nakdong River Basin and Behavior under Drinking Water Treatment Processes)

  • 손희종;염훈식;정종문;장성호;김한수
    • 한국환경과학회지
    • /
    • 제21권7호
    • /
    • pp.837-843
    • /
    • 2012
  • The aims of this study were to investigated the occurrence of caffeine and carbamazepine in Nakdong river basin (8 mainstreams and 2 tributaries) and the behavior of caffeine and carbamazepine under drinking water treatment processes (conventional and advanced processes). The examination results showed that caffeine was detected at all sampling sites (5.4~558.5 ng/L), but carbamazepine was detected at five sampling sites (5.1~79.4 ng/L). The highest concentration level of caffeine and carbamazepine in the mainstream and tributaries in Nakdong river were Goryeong and Jinchun-cheon, respectively. These pharmaceutical products were completely removed when they were subject to conventional plus advanced processes of drinking water treatment processes. Conventional processes of coagulation, sedimentation and sand-filtration were not effective for their removal, while advanced processes of ozonation and biological activated carbon (BAC) filtration were effective. Among these pharmaceuticals, carbamazeoine was more subject to ozonation than caffeine.

일산화탄소 저감을 위한 개질가스의 전이반응 연구 (Investigation of the Water Gas Shift from Reforming Gas for CO Removal)

  • 김성천;윤문중;전영남
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.855-859
    • /
    • 2007
  • Hydrogen as an energy carrier in fuel cell offers perhaps the largest potential benefits of reduced emissions of pollutants and greenhouse gases. The generation of high-purity hydrogen from hydrocarbon fuels is essential for efficient operation of fuel cell. Reduction of carbon monoxide to an acceptable level of 10ppm involves high temperature and low temperature water gas shift (WGS), followed by selective oxidation of residual carbon monoxide. The WGS reactor was designed and tested in this study to produce hydrogen-rich gas with CO to less than 5000 ppm. In the water gas shift operation, gas emerges from the reformer is taken through a high temperature shift (HTS) catalyst to reduce the CO concentration to about $2{\sim}4%$ followed to about 5000 ppm via a low temperature shift (LTS) catalyst.

UV, 전기분해 및 UV+전기분해 공정을 이용한 해수 중의 동물성 플랑크톤 제거 (Zooplankton Removal in Seawater using UV, Electrolysis and UV+electrolysis Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제30권7호
    • /
    • pp.597-604
    • /
    • 2021
  • The International Maritime Organization (IMO) ballast water management agreement (International Convention for the Control and Management of Ship's Ballast Water and Sediments) came into force on September 8, 2017. This study evaluated the disinfection performance of electrolysis, UV treatment, and electrolysis + UV combined, to improve the treatment of zooplankton (size ≥ 50 ㎛), which is expected to strengthen the standards for biodegradation efficiency. Among the methods used, the disinfection time leading to 100% death was in the order: electrolysis > electrolysis + UV > UV process. For the same level of disinfection performance, the amount of electricity required for the electrolysis, UV, and electrolysis + UV processes were 1,300 W.s, 8,400 W.S, and 4,500 W.s, respectively. The combination of electrolysis + UV process for inactivation of zooplankton in ballast water did not show a synergic effect owing to the slow disinfection time and high power consumption.

원전 증기발생기 수위제어계통의 고장검출 시스템 설계 (A Fault Detection System Design for Nuclear Steam Generator Level Control System)

  • 류석환;최병재
    • 한국지능시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.191-197
    • /
    • 2006
  • 본 논문에서는 원저 증기발생기 수위제어계통을 위한 고장검출 시스템을 설계한다. 이를 위하여 증기발생기 수위제어계통의 비선형 동적방정식을 미지의 매개변수를 갖는 T-S 퍼지시스템으로 모델링하고 좌 소인수 분해를 이용하여 오차발생기를 설계한다. 고장검출의 성능을 향상시키기 위하여 고장검출 필터의 설계법을 제안한다. 제시한 방법의 효용성을 컴퓨터 모의실험을 통하여 입증한다.

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

모형 수도관에서 염소와 모노클로라민에 의한 생물막 제거 특성 비교 (Comparison of Biofilm Removal Characteristics by Chlorine and Monochloramine in Simulated Drinking Water Distribution Pipe)

  • 박세근;최성찬;김영관
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.26-33
    • /
    • 2006
  • 본 연구에서는 염소와 모노클로라민을 이용하여 생물막이 제거되는 특성을 알아보았다. 염소와 모노클로라민을 0.5, 1.0, 2.0 mg/L의 농도로 잔류시킨 수돗물을 생물막이 형성되어 있는 모형 수도관에 연속적으로 공급하고, 관 표면으로부터 부착성 HPC와 biomass를 측정하였다. 염소는 생물막을 구성하는 미생물의 비활성화와 표면으로부터 생물막 matrix를 제거하는데 높은 효과를 나타낸 반면에 모노클로라민은 생물막 matrix를 제거하는데 염소보다 상대적으로 낮은 효율을 나타냈다. 특히 모노클로라민을 이용한 소독 처리에서는 세균과 EPS가 결합된 생물막 matrix가 관 표면으로부터 대부분 제거되지 않은 상태로 존재하였다. 비록 2.0 mg/L의 잔류염소가 생물막 제거에 높은 효과를 보였지만, 관 표면에는 여전히 낮은 수준(<10 $CFU/cm^2$ as 부착성 HPC, <5 ${\mu}g/cm^2$ as biomass)의 생물막이 잔류하고 있었다. 생물막의 제거 특성을 평가하는데 있어서 biomass의 측정이 효과적인 수단인 것으로 판단되었다.

안동댐 퇴적물의 오염도 평가(II): 안동댐 퇴적물에 대한 영양염류 및 중금속 용출 특성 연구 (Assessment of Pollution Characteristics of Surface Sediments from Lake Andong(II): Studies on the Nutrient and Heavy Metal Release Characteristics from Sediments in Andong Dam)

  • 김영훈;박재충;신태천;김정진
    • 광물과 암석
    • /
    • 제33권4호
    • /
    • pp.391-405
    • /
    • 2020
  • 본 연구에서는 안동댐 퇴적물의 일반항목과 중금속의 용출 특성에 대해 조사하였다. 용출 실험은 카드뮴, 구리, 납, 크롬, 아연, 수은, 비소, 철, 망간 등 중금속 9개 및 pH, 총인, 총질소등 일반 3개 항목에 대해 혐기성과 호기성 조건에서 60일간 실험을 수행하였다. 총질소와 총인은 호기성 조건에 비해 혐기성 조건의 용출이 높게 나타났으며, 일부 시료에서 높은 농도가 검출되었다. 대부분의 중금속의 용출율은 아주 낮았으며, 퇴적물에서 함유량이 높은 비소와 카드뮴도 최대 용출량이 각각 0.028 mg/L, 0.003 mg/L로 낮은 값을 나타낸다. 5단계 연속추출연구에서는 쉽게 용출될 수 있는 이온교환형태나 흡착한 형태의 분율이 전체 함유량의 10% 미만으로 낮게 나타났다. 대부분의 중금속은 왕수에 용해되는 잔류(residual)형태로 존재하고 있으며, 특히 독성이 높고 오염도가 높은 비소와 카드뮴의 경우 잔류형태로 존재하는 비율이 각각 80%와 95%로 오염도에 비해 짧은 시간에 용출되어 유해성을 일으킬 가능성은 낮은 것으로 판단된다.