• Title/Summary/Keyword: Residual water

Search Result 1,352, Processing Time 0.026 seconds

Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan (수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안)

  • Han, Keum-Seok;Park, Ju-Hyun;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Choi, In-cheol;Hong, Seong-Ho
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water (전기분해수 살균효과 및 소독부산물 생성 특성 평가)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

Prediction of Chlorine Residual in Water Distribution System (상수관망내 잔류염소농도 분포 예측)

  • Joo, Dae-Sung;Park, No-Suk;Park, Heek-Yung;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.118-124
    • /
    • 1998
  • To use chlorine residual as an surrogate parameter of the water quality change during the transportation in the water distribution system(WDS), the correct prediction model of chlorine residual must be established in advance. This paper shows the procedure and the result of applying the water quality model to the field WDS. To begin with, hydraulic model was calibrated and verified using fluoride as an tracer. And chlorine residual was predicted through simulation of water quality model. This predicted value was compared with the observed value. With adjusting the bulk decay coefficient(kb) and the wall decay coefficient(kw) according to the pipewall environment, the predicted chlorine residual can represent the observed value relatively well.

  • PDF

Prediction Models of Residual Chlorine in Sediment Basin to Control Pre-chlorination in Water Treatment Plant (정수장 전염소 공정 제어를 위한 침전지 잔류 염소 농도 예측모델 개발)

  • Lee, Kyung-Hyuk;Kim, Ju-Hwan;Lim, Jae-Lim;Chae, Seon Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.601-607
    • /
    • 2007
  • In order to maintain constant residual chlorine in sedimentation basin, It is necessary to develop real time prediction model of residual chlorine considering water treatment plant data such as water qualities, weather, and plant operation conditions. Based on the operation data acquired from K water treatment plant, prediction models of residual chlorine in sediment basin were accomplished. The input parameters applied in the models were water temperature, turbidity, pH, conductivity, flow rate, alkalinity and pre-chlorination dosage. The multiple regression models were established with linear and non-linear model with 5,448 data set. The corelation coefficient (R) for the linear and non-linear model were 0.39 and 0.374, respectively. It shows low correlation coefficient, that is, these multiple regression models can not represent the residual chlorine with the input parameters which varies independently with time changes related to weather condition. Artificial neural network models are applied with three different conditions. Input parameters are consisted of water quality data observed in water treatment process based on the structure of auto-regressive model type, considering a time lag. The artificial neural network models have better ability to predict residual chlorine at sediment basin than conventional linear and nonlinear multi-regression models. The determination coefficients of each model in verification process were shown as 0.742, 0.754, and 0.869, respectively. Consequently, comparing the results of each model, neural network can simulate the residual chlorine in sedimentation basin better than mathematical regression models in terms of prediction performance. This results are expected to contribute into automation control of water treatment processes.

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Infiltration Characteristics for Unsaturated Residual Soil (화강풍화토의 불포화 침투특성에 관한 연구)

  • 김영욱;김도형;성상규;이인모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.147-152
    • /
    • 2001
  • This study investigated one-dimensional vertical infiltration to an unsaturated residual soil by numerical solutions, FDM. In order to estimate the parameters needed for numerical analysis, tire soil-water characteristic curve(SWCC) of Shinnae-dong soil, one of the most typical residual soils in Korea, were experimentally obtained. Then, the statistical analysis for obtaining the SWCC was performed. The numerical solution to the linearized governing equation for unsaturated groundwater flow provides the infiltration characteristics for the unsaturated residual soil represented by transient pressure profiles and water contents profiles.

  • PDF

A Microbiological Study on the Tap Water in Seoul (서울시 수도수 중의 위생물학적 조사연구)

  • 조영채
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 1981
  • This study was carried out to investigate Water Temperature, Residual Chlorine, Coliform Groups, and the Standard Plate Counts of Water Supply Areas provided by 7 Water Purification Plant (W.P.P) in Seoul from September 20, 1979 through October 20, 1979. The results were summarized below: 1) The mean water temperature of the 63 Water Samples was 19.8$\circ$C, the mean pH 7.18, and the mean residual chlorine concentration 0.52 ppm by each Water Supply Areas. There is no statistically significant differences between the WPP Areas, but there is significant differences between water supply areas. 2) 30(47.6%) out of the 63 Water Samples were Standard Plate Counts free and 33 Samples (52.4%) were contaminated by Standard Plate Counts. 30 (47.6%) out of 33 samples showed the existence of Standard Plate Counts less than 15 and the other 3 samples 15-30. 3) 2 (3.2%) out of the 63 Samples had the coliform. Those 2 Samples had 2 and 6 coliform group counts per 50ml respectively both of them were 0.1ppm in residual chlorine. 4) There is correlation among Water Temperature, pH, Residual Chlorine, Standard Plate Counts, and Coliform Groups. The Coefficient of Correlation(r) between Water Temperature & Residual Chlorine was 0.147, 0.240 between Water Temperature & Standard plate Counts and 0.215 between pH & Standard Plate Counts. These correlations are statistically no significant, But the correlation of coefficient between pH & Residual Chlorine was -0.291 which is showed significant correlation at p<0.05. The coefficient of correlation between Residual Chlorine & Standard Plate Counts was -0.441 which is showed Negative Correlation Statistically Significant difference at p<0.01.

  • PDF

Development of optimization model for booster chlorination in water supply system using multi-objective optimization method (다목적 최적화기법을 활용한 상수도 공급계통 잔류염소농도 최적운영 모델 개발)

  • Kim, Kibum;Seo, Jeewon;Hyung, Jinseok;Kim, Taehyeon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, a model to optimize residual chlorine concentrations in a water supply system was developed using a multi-objective genetic algorithm. Moreover, to quantify the effects of optimized residual chlorine concentration management and to consider customer service requirements, this study developed indices to quantify the spatial and temporal distributions of residual chlorine concentration. Based on the results, the most economical operational method to manage booster chlorination was derived, which would supply water that satisfies the service level required by consumers, as well as the cost-effectiveness and operation requirements relevant to the service providers. A simulation model was then created based on an actual water supply system (i.e., the Multi-regional Water Supply W in Korea). Simulated optimizations were successful, evidencing that it is possible to meet the residual chlorine concentration demanded by consumers at a low cost.

Application of Rechlorination for Adequate Disinfection Ability in Water Distribution System (관로 내 적정소독능 확보를 위한 재염소 기법의 적용)

  • Lee, Doo-Jin;Kim, Young-Il;Lee, Jong-Min;Jung, Nam-Jung;Kim, Yong-Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.701-707
    • /
    • 2006
  • Disinfectant residual should be maintained to achieve biological stability during distribution of treated water. The wide distribution of retention times associated with storage and transport of water in a network and the reactivity of disinfectants make it difficult to maintain adequate residuals at critical locations. Rechlorination at some intermediate locations may reduce the total disinfectant dose while keeping residuals within specified limits throughout the water distribution system. In order to select the adequate location of rechlorination for achieving to maintain of residual chlorine throughout the distribution system, EPANET was used in this study. EPANET was well predicted chlorine transport and residual loss in the distribution system. Location of rechlorination was selected to maintain 0.4mg/L of residual chlorine throughout a water distribution system by field investigation and model simulation. The quantity of chlorine may reduced 36.7% and provided smooth residual between 0.42 and 0.60mg/L, when rechlorination would be used continuously at strategic location within the distribution system.

Design of Residual Treatment Process with Filter Backwash Recycle System (역세척수 회수시스템이 포함된 배출수처리공정의 설계)

  • Bae, Byung-Uk;Choi, Kyung-Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.109-114
    • /
    • 2012
  • In this study, both sedimentation and thickening experiments were conducted for residuals produced from an advanced water treatment plant for more accurate and practical design of residual treatment train. In order to design a backwashed residual sedimentation basin (SRSB) in the filter backwash water recycle system, two kinds of backwash waters, one from sand filter (SFBW) and the other from GAC adsorption bed (GACBW), were separately collected and their surface loading rate measured. In addition, in order to design a gravity thickener, batch thickening tests were conducted for concentrated residuals taken from sedimentation basin and their limiting solid flux ($SF_{L}$) measured. From the experimental results and consideration of the seasonal characteristics of the residual, surface loading rate of $70m^{3}/m^{2}{\cdot}d$ was proposed as a design parameter for SRSB and solid loading rate of 20 kg $TS/m^{2}{\cdot}d$ was proposed as a design parameter for gravity thickeners. Finally, the material mass-balance was made for the design of each unit process in the residual treatment train.