• Title/Summary/Keyword: Residual volume

Search Result 426, Processing Time 0.03 seconds

Bleeding Efficiency and Meat Oxidative Stability and Microbiological Quality of New Zealand White Rabbits Subjected to Halal Slaughter without Stunning and Gas Stun-killing

  • Nakyinsige, K.;Fatimah, A.B.;Aghwan, Z.A.;Zulkifli, I.;Goh, Y.M.;Sazili, A.Q.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.3
    • /
    • pp.406-413
    • /
    • 2014
  • A study was conducted to compare the effect of halal slaughter without stunning and gas stun killing followed by bleeding on residual blood content and storage stability of rabbit meat. Eighty male New Zealand white rabbits were divided into two groups of 40 animals each and subjected to either halal slaughter without stunning (HS) or gas stun-kill (GK). The volume of blood lost during exsanguination was measured. Residual blood was further quantified by determination of haemoglobin content in Longissimus lumborum (LL) muscle. Storage stability of the meat was evaluated by microbiological analysis and measuring lipid oxidation in terms of thiobarbituric acid reactive substances (TBARS). HS resulted in significantly higher blood loss than GK. HS had significantly lower residual haemoglobin in LL muscle compared to GK. Slaughter method had no effect on rabbit meat lipid oxidation at 0, 1, and 3 d postmortem. However, at 5 and 8 days of storage at $4^{\circ}C$, significant differences (p<0.05) were found, with meat from the GK group exhibiting significantly higher levels of MDA than that from HS. At day 3, greater growth of Pseudomonas aeroginosa and E. coli were observed in the GK group (p<0.05) with B. thermosphacta and total aerobic counts remained unaffected by slaughter method. At days 5 and 7 postmortem, bacterial counts for all tested microbes were affected by slaughter method, with GK exhibiting significantly higher growth than HS. It can be concluded that slaughter method can affect keeping quality of rabbit meat, and HS may be a favourable option compared to GK due to high bleed out.

Analysis of Flow Field in the Circular Water Tank According to the Number of Baffles (원형 물탱크내의 격벽수에 따른 유동장 해석)

  • Kim, Jung-Hwan;Kang, Dong-Youl;Jung, Tae-Jun;Kim, Se-Young;Choi, Jong-Wook;Chu, Byeong-Gil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The concentration of residual chlorine should be kept at over 0.1 mg/L in the circular water tank used in a water purification system. Generally, the concentration of residual chlorine depends on the structure and the volume of water tank, and also the water flow rate. To secure the diffusion time is important to the concentration of residual chlorine. For that reason, the baffles are installed in the circular water tank. In the present study, the variations of water and chlorine concentration were obtained with time using the numerical analysis. And also, the streamlines were shown according to the number of baffles. As a results, the vortex flow appeared between baffles, and the diffusion time of chlorine increased with the more number of baffles.

Ventilatory Responses to Continuous Negative Pressure Breathing(CNPB) in Awake Dogs

  • Cha, Eun-Jong;Goo, Yong-Sook
    • The Korean Journal of Physiology
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 1993
  • Ventilatory responses to inhaled $CO_2$ were measured during continuous negative pressure breathing (CNPB) in awake dogs. End expiratory lung volume (EELV) decreased linearly with pressure level during CNPB (correlation coefficient= 0.81, p<0.005) during air breathing. When CNPB was applied during 5% $CO_2$ inhalation, the decrease in EELV was not significantly different (p<0.5) from that during air breathing. As a result of a lowered EELV, tidal volume ($V_T$) significantly decreased by 22% and breathing frequency ($f_B$) increased by 68% in the steady state during air breathing (p<0.0001). These responses were similar during 5% $CO_2$ inhalation, thus the $CO_2$ response curve measured during CNPB shifted upward without a change in sensitivity (p>0.05). These results indicate additive effects of CNPB and $CO_2$ inhalation. The degree of hyperventilation during CNPB at eupnea was estimated to be 63% of that during control ventilation and was significantly greater than zero (p<0.0001), which suggests an alveolar hyperventilation due to CNPB. These results suggest that the mechanical alterations associated with n decrease in lung volume could play an important role in ventilatory control independently of chemical regulation of breathing. Thus, exercise hyperpnea, which is associated with a lowered functional residual capacity (FRC), may in part be explained by this mechanical stimulation of breathing.

  • PDF

SECONDARY REPAIR OF LATE ENOPHTHALMOS WITH CALVARIAL BONE GRAFTS AROUND INTRAORBITAL CONTENT -REPORT OF 2 CASES- (안와주위에 두개골이식을 통한 안구함몰의 이차적 성형재건 치험례)

  • Kim, Sung-Gil
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.373-378
    • /
    • 1998
  • In the midfacial fracture, the orbital region presents many additional complication unique to the orbit. Among them are ectropion, entropion, lid ptosis, injury to the lacrimal apparatus, diplopia or the late development of enophthalmos. The residual problem confronting the surgen is usually enophthalmos or diplopia. Enophthalmos becomes cosmetically obvious at 3mm and if more severe it can interfere with vision from obstruction by the orbital rim. In this clinical situation, many patients prefer the simpler intraorbital volume expansion to the more complex orbital osteotomy. In general, except in mild cases of enophthalmos, the procedure of choice is osteotomy and repositioning for zygoma fracture and volume augmentation for blow-out fracture. Late treatment is performed by volume augmentation based on the CT findings behind the axis of the globe. Inferiorly placed grafts elevate the globe, posterior superior grafts move the globe anterior and medially positioned grafts push the globe laterally. In this two cases, the patients who has stable orbitozygomatic rim, the use of calvarial bone grafts more than 3 areas around intraorbital content, we corrected late enophthalmos combined with diplopia. As result, the first patient had 2mm advance in exophthalmometric check with improvement of the diplopia gradually. The second patient had 1.5mm advance with correction of vertical ocular dystopia and cosmetically good results respectively.

  • PDF

Cesium Removal from Soil Contaminated with Radioactivity Using Electrokinetic Method (동전기적방법을 이용한 방사능오염토양 내의 세슘 제거)

  • 김계남;원휘준;김민길;박진호;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.696-700
    • /
    • 2003
  • $H_2SO_4$ and citric acid had higher extraction efficiency of $^{137}Cs$ from soil than the other chemicals. Thus, $H_2SO_4$and citric acid were used as additives on remediation experiment by electrokinetic method to increase removal efficiency of $^{137}Cs$ from the radioactive soil being stored during a long time. An average velocity of effluent discharged from experimental column $2.0{\times}10^{-2}$/cm/min and a volume of the discharged soil wastewater for 10 days is 3.6 Pore Volume. The 54% of a total of $^{137}Cs$ in the column was decontaminated for 10 days. Furthermore, the predicted values of residual concentration by the developed model were quite similar to those obtained from experiments.

  • PDF

Selection of Reference Equations for Lung Volumes and Diffusing Capacity in Korea (우리나라 성인 폐용적 및 폐확산능 정상예측식의 선정)

  • Song, Eun Hee;Oh, Yeon Mok;Hong, Sang Bum;Shim, Tae Sun;Lim, Chae Man;Lee, Sang Do;Koh, Youn Suck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Kim, Tae Hyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.3
    • /
    • pp.218-226
    • /
    • 2006
  • Background: The lung volume and diffusing capacity are influenced by ethnicity. However, there are no equations for predicting the normal lung volume in the adult Korean population, and there is only one equation for diffusing capacity. The aim of this study is to select the most suitable reference equation for the Korean population. Method: 30 men and 33 women at Hanyang University Guri Hospital, and 27 men and 34 women at Asan Medical Center in healthy nonsmoking adults were enrolled in this study. The subject's age, gender, height, weight, lung volume by plethysmography, and diffusing capacity by a single breathing method were obtained. The most suitable equation with the lowest sum of residuals between the observed and predicted values for lung volume and diffusing capacity was selected. Result: At Hanyang University Guri Hospital, the equations with the lowest sum of residuals in the total lung capacity were ECSC's equation in males (sum of residual: 0.04 L) and Crapo/Morris's equation (-1.04) in women. At the Asan Medical Center, the equations with the lowest sum of residuals in the total lung capacity were Goldman/Becklake's equation in males (sum of residual: -2.35) and the ECSC's equation -4.49) in women. The equations with the lowest sum of residuals in the Diffusing capacity were Roca's equation in males (sum of residual: -13.66 ml/min/mmHg) and Park's in women (25.08) in Hanyang University Guri hospital and Park's equation in all cases in the Asan Medical Center (male: -1.65, female: -6.46). Conclusions: Until a reference equstion can be made for healthy Koreans by sampling, ECSC's equation can be used for estimating the lung volume and Park's can be used for estimating the diffusing capacity.

Development and Application of a Feeding Program for Infants Postoperatively following Cardiac Surgery (심장수술 받은 영아의 영양중재프로그램 개발 및 적용)

  • Moon, Ju-Ryoung;Cho, Yong Ae;Min, Sun-In;Yang, Ji-Hyuk;Huh, June;Jung, Yeon-Yi
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.4
    • /
    • pp.508-517
    • /
    • 2009
  • Purpose: Despite recent advances in the surgical and postoperative management of infants with congenital heart disease, nutritional support for this population is often suboptimal. The purpose of this study was to develop a nutritional program for the postoperative period for infants who have had cardiac surgery and to evaluate effects of the program. Methods: A quasi-experimental design with pretest and posttest measures was used. A newly developed nutritional program including a feeding protocol and feeding flow was provided to the study group (n=19) and usual feeding care to the control group (n=19). The effects of the feeding program were analyzed in terms of total feed intake, total calorie intake, gastric residual volume, and frequency of diarrhea. Results: Calorie intake and feeding amount in the study group were significantly increased compared to the control group. However, the two groups showed no significant differences in gastric residual volume and frequency of diarrhea. Conclusion: The results indicate that the nutritional program used in the study is an effective nursing intervention program in increasing feeding amount and calorie intake in infants postoperative to cardiac surgery and does not cause feeding-related complications.

Stereotactic Multiplanar Reformatted Computed Tomography-Guided Catheter Placement and Thrombolysis of Spontaneous Intracerebral Hematomas

  • Hwang, Jae-Ha;Han, Jong-Woo;Park, Kyung-Bum;Lee, Chul-Hee;Park, In-Sung;Jung, Jin-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.185-189
    • /
    • 2008
  • Objective : The authors present their experiences with stereotactic multiplanar reformatted (MPR) computed tomography (CT)-guided catheter placement for thrombolysis of spontaneous intracerebral hematoma (sICH) and their clinical results. Methods : In 23 patients with sICH, MPR CT-guided catheter placement was used to select the trajectory and target point of hematoma drainage. This group was comprised of 11 men and 12 women, and the mean age was 57.5 years (range, 31-79 years). The patients' initial Glasgow Coma Scale scores ranged from 7 to 15 with a median of 11. The volume of the hematoma ranged from 24 mL to 86 mL (mean 44.5 mL). A trajectory along the main axis of the hematoma was considered to be optimal for thrombolytic therapy. The trajectory was calculated from the point of entry through the target point of the hematoma using reformatted images. Results : The hematoma catheter was left in place for a median duration of 48.9 hours (range 34 to 62 hours). In an average of two days, the average residual hematoma volume was 6.2 mL (range 1.4 mL to 10.2 mL) and was reduced by an average of 84.7% (range 71.6% to 96.3%). The residual hematoma at postoperative seven days was less than 5 mL in all patients. There was no treatment-related death during hospitalization. Conclusion : The present study indicates that stereotactic MPR CT-guided catheter placement for thrombolysis is an accurate and safe procedure. We suggest that this procedure for stereotactic removal of sICH should be considered for the optimization of the trajectory selection in the future.

Correlation Between Mechanical Behavior and Electrical Resistance Change in Carbon Particle Dispersed Plastic Composite

  • Song, D.Y.;Takeda, N.;Kim, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.377-382
    • /
    • 2001
  • Mechanical behavior and electrical resistance change of CPDP (carbon particle dispersed plastic) composite consisting of epoxy resin and conductive carbon particle were investigated under monotonic loading and repeated loading-unloading. The electrical resistance almost linearly increased with increasing strain during loading and the residual electrical resistance was observed even after removing load. The value of the residual electrical resistance was dependent on the maximum strain under the applied stress. This result suggests that the estimation of maximum strain (i.e., damage) is possible by the measuring electrical resistance of composite. The behavior of electrical resistance change during and after loading was discussed on the basis of the results of microscopic deformation and fracture observation. Moreover, the relationship between the volume fraction of carbon particle and the electrical resistivity of CPDP was investigated in relation to the percolation theory. Simulation model of percolation structure was established by Monte Carlo method and the simulation result was compared to the experimental results. The electrical resistance change under applied loading was analyzed quantitatively using the percolation equation and a simple model for the critical volume fraction of carbon particle as a function of the mechanical stress. It was revealed that the prediction was in good agreement with the experimental result except in the region near the failure of material.

  • PDF

A prospective study on the effectiveness of newly developed autogenous tooth bone graft material for sinus bone graft procedure

  • Jun, Sang-Ho;Ahn, Jin-Soo;Lee, Jae-Il;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.528-538
    • /
    • 2014
  • PURPOSE. The purpose of this prospective study was to evaluate the effectiveness of newly developed autogenous tooth bone graft material (AutoBT)application for sinus bone graft procedure. MATERIALS AND METHODS. The patients with less than 5.0 mm of residual bone height in maxillary posterior area were enrolled. For the sinus bone graft procedure, Bio-Oss was grafted in control group and AutoBT powder was grafted in experimental group. Clinical and radiographic examination were done for the comparison of grafted materials in sinus cavity between groups. At 4 months after sinus bone graft procedure, biopsy specimens were analyzed by microcomputed tomography and histomorphometric examination for the evaluation of healing state of bone graft site. RESULTS. In CT evaluation, there was no difference in bone density, bone height and sinus membrane thickness between groups. In microCT analysis, there was no difference in total bone volume, new bone volume, bone mineral density of new bone between groups. There was significant difference trabecular thickness ($0.07{\mu}m$ in Bio-Oss group Vs. $0.08{\mu}m$ in AutoBT group) (P=.006). In histomorphometric analysis, there was no difference in new bone formation, residual graft material, bone marrow space between groups. There was significant difference osteoid thickness ($8.35{\mu}m$ in Bio-Oss group Vs. $13.12{\mu}m$ in AutoBT group) (P=.025). CONCLUSION. AutoBT could be considered a viable alternative to the autogenous bone or other bone graft materials in sinus bone graft procedure.