• 제목/요약/키워드: Residual correction

검색결과 199건 처리시간 0.024초

Clavicle Fracture Site Surgical Contouring: A Case Report

  • Annachiara Cavaliere;Vincenzo Cepparulo;Giuseppe Pezone;Fabrizio Schonauer
    • Archives of Plastic Surgery
    • /
    • 제51권1호
    • /
    • pp.67-71
    • /
    • 2024
  • Clavicle fractures are frequent injuries accounting for approximately 4% of all fractures in adults with about 35% occurring in the shoulder region among which midshaft fractures are the most common (>66%). Nonsurgical management is the treatment of choice for most clavicle fractures; however, poor functional and aesthetic outcomes may result from nonunion, symptomatic malunion, and aesthetic impairment which are the most common complications. A young woman was referred to our clinic for a "Step Deformity" resulting after primary, nonsurgical treatment of a midshaft clavicle fracture. Residual deformity was corrected with a novel simple and little invasive approach. Midshaft clavicle fractures typically only require conservative nonsurgical treatment, nevertheless suboptimal outcomes may occur. Selective osteotomies and fixation are deemed too invasive when only cosmetic impairment of the clavicle contour is present without any functional or sensitive damage and most patients are discouraged from undergoing surgery. Thus far, no specific focus on this topic, nor exploration of possible correction can be found in the published literature. These residual deformities may be very noticeable sometimes and cause psychological distress and social life impairment. Despite no related functional impairment, this deformity should still be addressed, to improve patients' quality of life.

육상 탄성파자료에 대한 나머지 정적보정의 효과: 주행시간 분해기법과 겹쌓기제곱 최대화기법 (Application of Residual Statics to Land Seismic Data: traveltime decomposition vs stack-power maximization)

  • 사진현;우주환;이철우;김지수
    • 지구물리와물리탐사
    • /
    • 제19권1호
    • /
    • pp.11-19
    • /
    • 2016
  • 나머지 정적보정 기법중에서 가장 많이 쓰이는 주행시간 분해기법과 겹쌓기제곱 최대화기법의 적용성을 육상 탄성파자료에서 비교 검토하였다. 모든 발파점과 수신점에 대한 임의의 나머지 정적보정값(시간차이)과 무작위 잡음이 포함된 모델자료에서 겹쌓기제곱 최대화기법은 주행시간 분해기법에 비해 흐트러진 반사 이벤트를 정확히 정렬시키고 보정과정에서 출력된 발파점과 수신점의 정적보정 그래프가 입력된 값과 거의 같은 진폭으로 역전된다는 점에서 신호대잡음이 작은 자료의 반사면 향상에 보다 효과적이었다. 나머지 정적보정에 적합한 입력인자(최대허용 시간차이, 상관창, 반복횟수)들은 공통중간점 자료외에 공통발파점 겹쌓기자료와 공통수신점 겹쌓기자료에 대한 연속 테스트를 거쳐 효과적으로 진단할 수 있었다. 나머지 정적보정에 앞서 송수신점의 높이보정 및 풍화대 깊이보정을 실시하여 장파장 시간차이를 제거하고 진동수-파수 필터링, 예측곱풀기, 시간변화 빛띠흰색화로 잡음을 줄여 교차상관의 오차를 최소화시킨다. 또한 나머지 정적보정후 수직시간차 역보정을 거쳐 속도를 재분석하여 겹쌓기한 결과 저류층을 포함한 반사면들의 향상된 연속성 및 분해능을 확인할 수 있었다.

하구하상 측량 정밀도 향상에 관한 연구 (Study on the Accuracy Improvement for Survey of Estuary Riverbed)

  • 박운용;김천영;김용보
    • 한국측량학회지
    • /
    • 제21권2호
    • /
    • pp.137-145
    • /
    • 2003
  • Echo Sounder와 GPS의 조합에 의한 3차원 지형측량은 최근 해양 및 하천에서의 구조물 설치, 준설 및 매립, 해저 및 하상 지형변화 관측 등 그 활용도가 매우 높아지고 있다. 이 경우 수심측량의 오차는 GPS와 Echo Sounder의 조합에 의해 발생되는 형태와 Echo Sounder자체에서 발생되는 형태로 나눌 수 있다. 본 연구에서는 Echo Sounder자체에서 발생하는 경우에 있어 특히 음파의 반사면인 해저, 하상의 지질 상태에 따른 오차를 분석하고 해결방안을 제시하고자 한다. 이를 위해 실제 하구하상에서 채취한 시료를 이용한 수조 실험을 수행하여 평균입도-Echo Sounder 잔차와의 관계를 파악 오차보정식을 제시하고, 제시된 오차보정식의 신뢰도를 높이기 위해 검증시험을 수행하였다. 그 결과 하구하상 지형측량시 측량대상지의 지질 상태를 사전 조사, 사전 측량하면 Echo Sounder의해 발생된 오차의 크기를 추정, 보정할 수 있는 오차 보정식을 제시하였다.

X-선 회절 장비의 기계적 오차 수정을 통한 분석 정확도 향상 (Improvement of Measurement Accuracy by Correcting Systematic Error Associated with the X-ray Diffractometer)

  • 최두호
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.97-101
    • /
    • 2017
  • X-선 회절기(X-ray diffractometer)는 시편에서 회절되는 회절빔을 이용하여 재료의 상 (phase), 집합조직 (texture), 격자상수 (lattice constant), 잔류응력 (residual stress) 등 다양한 재료물성을 분석하는 데 광범위하게 사용되는 장치이다. X-선을 이용한 정량적인 분석은 회절빔의 피크 위치를 바탕으로 수행되는 데, 장시간 X-선 회절기를 사용하게 되면 필연적으로 장치 부품에 미세 변형이 발생하게 되고, 이러한 기계적인 오차가 발생하면 정량적인 분석의 정확도가 떨어지게 된다. 본 연구에서는 미국 표준기술연구소 (National Institute of Standards and Technology, NIST)에서 제공된 잔류응력이 없는 Si 파우더를 이용하여 $2{\theta}$를 기준으로 약 30~90도 사이 구간에 대해 X-선 회절 실험을 수행하였고, NIST에서 제공된 회절빔의 피크 위치와의 비교를 통하여 X-선 회절기의 계통오차를 파악하였으며, 이러한 오차 교정이 진격자상수 (true lattice constant) 측정 등 정량적인 분석에 미치는 영향을 확인하기 위하여 잔류응력이 존재하는 180 nm 두께의 텅스텐 박막에 대한 X-선 회절 분석을 수행하였다.

TEC-less 비냉각 열영상 검출기용 소형카메라 모듈 개발 (Small Camera Module for TEC-less Uncooled Thermal Image)

  • 김종호
    • 대한임베디드공학회논문지
    • /
    • 제12권2호
    • /
    • pp.97-103
    • /
    • 2017
  • Thermal imaging is mainly used in military equipment required for night observation. In particular, technologies of uncooled thermal imaging detectors are being developed as applied to low-cost night observation system. Many system integrators require different specifications of the uncooled thermal imaging camera but their development time is short. In this approach, EOSYSTEM has developed a small size, TEC-less uncooled thermal imaging camera module with $32{\times}32mm$ size and low power consumption. Both domestic detector and import detector are applied to the EOSYSTEM's thermal imaging camera module. The camera module contains efficient infrared image processing algorithms including : Temperature compensation non-uniformity correction, Bad/Dead pixel replacement, Column noise removal, Contrast/Edge enhancement algorithms providing stable and low residual non-uniformity infrared image.

대동맥궁 결손증의 완전교정 치험 1예 (Interrupted Aortic Arch(Type A) associated with PDA, VSD, Mitral Regurgitation and Single Coronary Artery)

  • 이재진
    • Journal of Chest Surgery
    • /
    • 제21권3호
    • /
    • pp.588-593
    • /
    • 1988
  • We experienced a case of interrupted aortic arch[Type A] associated with PDA, VSD, mitral regurgitation and single coronary artery. The patient was 7 years old boy, who showed congestive heart failure[NYHA functional class III]. One stage total correction was performed under profound hypothermia with total circulatory arrest. Aortic continuity was established using PDA with anterior wall of main pulmonary artery flap. VSD was closed with Dacron patch and mitral regurgitation repaired by Reed`s annuloplasty method. The postoperative cardiac catheterization revealed no pressure gradient between ascending aorta and descending aorta, decreased pulmonary artery pressure and trivial residual shunt[Qp/Qs: 1.28]. The aortogram showed good continuity of the aorta without narrowing of the anastomotic site. During the period of 1 year follow up, heart failure symptoms were nearly subsided.

  • PDF

디지털 프린터의 출려특성기반 톤 보정 망점화 (A Tone Correction Halftone Method Based on Response Characteristic of Digital Printer)

  • 신지현
    • 한국인쇄학회지
    • /
    • 제15권1호
    • /
    • pp.71-83
    • /
    • 1997
  • In recent years, various kinds of organic photoreceptors have been used for copy machines based on electrophotography. Most of them are constructed into layered devices in which a photogeneration layer is separated from a charge transport layer. They are usually used with application of negative charges. Organic pigment have received considerable attention with phthalocyanine, squaraine, and azo compounds being used to construct zerograpgic photoreceptors with enhanced long wavelength sensitivity, residual potential and zerograpgic gain of squaraine photoconductor were measured from the photoinduced discharge curve. Most of synthesized squaraine derivative couldn`t use for CGM(charge generation material), but it knew that a part of one was able to use it within the possibility. A few appliance is used it know about dependence on CTM(charge transport material) of squaraine derivative. It could know that experiment`s result is 2.5-bis(4-N-N`-diethylaminophenyl)-1,3,4-oxadiazole(OXD) is the bestproduct.

  • PDF

양대동맥 우심실기시증의 전교정술 - 45예 보고 - (Total Correction of Double-Outlet Right Ventricle [DORV]: Report of 45 cases)

  • 서울의대
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1174-1179
    • /
    • 1990
  • Forty-five patients with double-outlet right ventricle[DORV] underwent complete intracardiac repair between July, 1983 and June, 1989. Patients with complete atrioventricular canal, atrioventricular discordance and uni-ventricular heart were excluded. The 32 male and 13 female patients ranged in age from 3 months to 15 years[mean 4 years]. Thirty-two patients had pulmonary stenosis. The early mortality was 11.ltd[5 /45] None of 27 died after a completely intraventricular repair. The mortality was 20%[1/5] for repair using transannular patch, 20% [1/5] for REV operation, 33.3%[1/3] for repair including extracardiac valved conduit, and 50% [1/2] for Jatene operation, respectively. Two modified Fontan procedures were performed without mortality. One died after Senning operation. Causes of early deaths included high residual right ventricular pressure[one patient] small left atrial and left ventricular volume[one patient], persisting severe pulmonary hypertension [one patient] and low cardiac output of unknown cause [two patients]. Complete heart block developed in one patient. Two late deaths occurred among the 40 operative survivors [5.0Po] from persisting severe pulmonary hypertension and bleeding at reoperation. Our results indicate that significant defects can be repaired with low mortality and morbidity.

  • PDF

Takayasu 동맥염에 병발한 관상동맥질환 치험 1예 (Surgical Correction of the Coronary Artery Disease in Takayasu`s Arteritis)

  • 정윤섭;송명근
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.296-302
    • /
    • 1991
  • Coronary artery involvement and myocardial ischemic symptom in Takayasu`s arteritis is uncommon Its presentation as coronary artery narrowing is a potentially lethal but correctable problem. In this case report, a 17-year-old woman of Takayasu`s arteritis with unstable anginal and moderate heart failure is presented. Her coronary angiogram showed that the main trunk of the left coronary artery was moderately narrowed and the proximal portion of the circumflex branch was severely obstructed and the right coronary artery was also narrowed diffusely. Simultaneously the patient had the moderate degree of mitral regurgitation. In order to save her life, the coronary bypass surgery using the saphenous veins and the modified Wooler`s mitral annuloplasty were done urgently, Immediate recovery was uneventful and the postoperative exercise capacity was markedly improved. But the long-term prognosis seems to be uncertain because of 3 reasons: 1] natural progress and complication of Takayasu`s arthritis; 2] fate of the saphenous vein grafts in a relatively young patient with aortitis; 3] residual mitral regurgitation. So long-term follow-up should be needed.

  • PDF

스튜어트 플랫폼의 견실한 순기구학 추정기 설계 (Robust estimator design for the forward kinematics solution of stewart platform)

  • 강지윤;김동환;이교일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.28-31
    • /
    • 1996
  • We propose an estimator design method of Stewart platform, which gives the 6DOF, positions and velcities of Stewart platform from the measured cylinder length. The solution of forward kinematics is not solved yet as a useful realtime application tool because of the complexity of the equation with multiple solutions. Hence we suggest an nonlinear estimator for the forward kinematics solution using Luenberger observer with nonlinear error correction term. But the way of residual gain selection of the estimator is not clear, so we suggest an algebraic Riccati equation for gain matrix using Lyapunov method. This algorithm gives the sufficient condition of the stability of error dynamics and can be extended to general nonlinear system.

  • PDF