Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.

The Determination of TRC using an Electrochemical Method (II: Pt electrode) (전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(II: Pt전극 이용))

  • Lee, JunCheol;Pak, DaeWon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.304-310
    • /
    • 2014
  • The conventional methods for total residual chlorine such as iodometry and DPD colorimetric can cause secondary pollution due to additional agents, also have a wide error range. As for alternative, electrochemical method can measure TRC(Total residual chlorine), and is not required as additional agents, also very suitable for using the fields of ballast water because test time is relatively fast. Therefore, this study was investigated for changing charge by agitation, salt concentration, and temperature change. Charge showed differences based on changes of reduction peak with or without agitation. In contrast, TRC and charge were well correlated in constant agitation speed. As TRC and charge were analyzed with high correlations in constant salinity and temperature of ocean, thereby conductivity was firstly measured, and charge had high correlation for TRC in spite of changing salinity and temperature Pt electrode revealed high reliability ($r^2=0.960$) because it was rarely effected by TRC, On the other hand, Au electrode appeared inadequate ($r^2=0.767$) to use sensor in less than 1.0 ppm of TRC. For high accuracy and detection of TRC, Pt and Au electrodes for test time were, respectively, 14 and 22 seconds. As a result, Pt electrode was more valuable than Au electrode in terms of response time.

The Determination of TRC using an Electrochemical Method (I: Au electrode) (전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(I: Au전극 이용))

  • Lee, JunCheol;Pak, DaeWon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.298-303
    • /
    • 2014
  • We measured by electrochemical method for TRC (total residual chlorine) in ocean. From the results of Au electrode used for working electrode through cyclic voltammetry test, we obtained charge in voltage ranged from 0.0V-1.0V, and analyzed correlations of charge for TRC. Reduction peak TRC was investigated to be approximately 0.65 V vs. Ag/AgCl, and in the case that salt concentrations and temperatures in ocean appeared different, charge was analyzed for being different in the same TRC. However, in the case that each condition was constant, charge was measured at highly correlations for TRC.

Preparation of Anode Material for Lithium Secondary Battery using Pitch-coated Graphite Residue Compounds

  • Ko, Young-Shin;Oh, Won-Chun
    • Carbon letters
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2007
  • The properties and electrochemical characteristics of anode material using pitch-coated graphite residue compounds by heat-treatment at $600^{\circ}C$ for 1 hour were investigated. The distance of layers of pitch-coated graphite residual compounds was 3.3539 ${\AA}$, which was as same as that of graphite. Its electrochemical and charge discharge characteristics were tested according to different four types of carbon material, natural graphite, pitch-coated graphite, amorphous graphite and pitch-coated graphite residual compounds, respectively. So it was shown the best charge-discharge characteristics in all of the samples. For the electrochemical and charge-discharge characteristics, although pitch-coated graphite residual compounds had different carbon contents 70% and 80%, these two samples were shown good electrochemical and charge-discharge characteristics.

Charge Estimation of Lead-acid batteries for Electric Vehicles (전기 자동차용 Lead-acid 축전지 잔류용량 측정)

  • Jeong, Byoung-Chang;Kwon, Soon-Shin;Lee, Seong-Ryong;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2724-2726
    • /
    • 1999
  • Various methods for estimation of residual charge of the lead-acid battery have been proposed. But no method can estimate accurately the residual capacity. A new method is proposed in this paper. And experiments were performed for verification of the proposed estimation method.

  • PDF

Space Charge Behaviors of New Insulating Materials for URD cables (새로운 지중배전케이블용 절연재료의 공간전하 거동)

  • 고정우;서광석;김종은;남윤선;김덕주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.207-210
    • /
    • 1998
  • Electrical properties such as space charge distribution and electrical conduction of XLPE/VLDPE blends were studied. When the VLDPE is blended, residual charge inside XLPE increases. In case of electrical conduction characteristics, there were no changes in electrical conduction mechanism, space charge limited conduction. XLPE/VLDPE blend including crosslinking coagent showed relatively small current density. It might be due to the carbonyl group in crosslinking coagent.

  • PDF

ENHANCED REMOVAL OF RESIDUAL ALUMINUM AND TURBIDITY IN TREATED WATER USING POLYMERS

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.155-164
    • /
    • 2005
  • This study investigated the possibility of reducing the residual aluminum (Al) in the treated water using polymers. Two raw waters (lake and river water) and three kinds of polymers (coagulant, flocculant, and filtration aids) were used for this purpose. This study found that coagulation at the high dose did not necessarily lead to the high concentration of the residual Al in the treated water. The coagulation efficacy was found more important in determining the residual Al than the coagulant dose. The use of a polymer enhanced the removal of turbidity as well as the residual Al. The coagulant aid removed the dissolved Al as well as the particulate Al by helping the coagulation and the solid-liquid separation. The flocculant aid and the filtration aid preferentially removed the particulate Al while helping the solid-liquid separation. The filtration aid reduced the residual Al substantially more effectively than the flocculant aid. The polyamine-based coagulant aid (FL) showed the better performance in reducing the residual Al and turbidity than DADMAC (WT). The cationic flocculant aid with weak charge density and the medium molecular weight (SC-020) showed the best performance in reducing the residual Al.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

A study on the preparation of phthalocyanine optoelectric thin films (프탈로시아닌계 광전도성 유기박막의 제조에 관한 연구)

  • 박구범;조기선;이덕출
    • Electrical & Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.409-416
    • /
    • 1994
  • A double layered photoreceptor using phthalocyanine dye was made by dip-coating method. The under cutting layer(UCL) was coated with A1$\_$2/O$\_$3/ or polyamide, and the charge generation layer(CGL) was formed by .tau.-type metal-free phthalocyanine. The oxadiazole was used as a charge transport layer(CTL) and polycarbonate and poly(vinyl butyral) was employed as a host polymer. The .tau.-H$\_$2/Pc had an absorption peak around 780nm, which coincided with the emitting wavelengths of GaAlAs diode lasers. Maximum charge acceptance of CTL that gives thickness of 12.mu.m was -900V by corona charge of -6.0kV. In photo-induced discharge measurements, residual potential was less than -20V and sufficient for ordinary use, and sample films using of poly(vinyl butyral) was showed good charge retention. In printing test, drum that was employed polycarbonate as a host polymer showed the good print quality.

  • PDF

A Study on Electrical properties of EPR by Irradiated by X-rays (방사선에 조사된 EPR 의 전기적 특성에 관한 연구)

  • Lee, Sung-Il;Iim, Gui-Yeul;Lee, Ho-Sik;Lee, Hee-Gab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.565-568
    • /
    • 2002
  • The value of charge current, discharge current, $\varepsilon_r$' $\varepsilon_r"$, residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated $CO^{60}\gamma$ ray 0-38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by $CO^{60}-{\gamma}$-irradiation dose The charging current and the discharging current of EPR increase, depending on the ratio of degradation. As the irradiation dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful $CO^{60}-{\gamma}$-irradiation dose. The increase of peak in $\varepsilon_r"$ is attrib uted to the irratiation dose almost proportionally.

  • PDF