• 제목/요약/키워드: Residual cement

검색결과 104건 처리시간 0.023초

고온 환경에 노출된 시멘트 경화체의 공극 구조 변화 (Pore Structure Changes in Hardened Cement Paste Exposed to Elevated Temperature)

  • 강승민;나승현;김경남;송명신
    • 한국세라믹학회지
    • /
    • 제52권1호
    • /
    • pp.48-55
    • /
    • 2015
  • Hardened cement-based materials exposed to the high temperatures of a fire are known to experience change in the pore structure as well as microstructural changes that affect their mechanical properties and tend to reduce their durability. In this experimental investigation, hardened Portland cement pastes were exposed to elevated temperatures of 200, 400, 600, 800, and $1000^{\circ}C$ for 60 minutes, and the resulting damage was studied by thermogravimetry (TG), mercury intrusion porosimetry (MIP) and density measurements. These results revealed that the residual compressive strength is increased at temperatures greater than $400^{\circ}C$ due to a small pore size of 3 nm and/or rehydration of the dehydrated cement paste. However, a loss of the residual strength occurs at temperatures exceeding 500 and $600^{\circ}C$. This can be attributed to the decomposition of hydrates such as portlandite and to an increase in the total porosity.

시멘트 유지형 임플란트 보철물의 신개념 유지 방식: Fiber post의 설측 수평 삽입에 의한 유지력 보완 (A new retaining method of cement-retained restoration with linguo-horizontal insertion of fiber post)

  • 윤나리;이성복;이석원;안수진;박수정
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.71-78
    • /
    • 2017
  • 임플란트 보철물을 지대주 및 임플란트에 연결하는 방법은 크게 나사 유지방식과 시멘트 유지방식으로 나눌 수 있다. 나사 유지형의 장점은 탈착 가능성과 잔류 시멘트가 남지 않는다는 점이나 상대적으로 나사 풀림이나 파절의 비율이 시멘트 유지방식에 비해 높다는 단점이 있다. 반면 시멘트 유지형은 심미적이고 상대적으로 적은 비용으로 보철물을 제작할 수 있으나 탈착의 용이성이 불리하다는 단점이 있다. 이 두 가지의 장점을 조합한 방식으로 SCRP방식이 소개되었다. 그러나 역시 이상적인 임플란트 식립 위치를 전제로 한다. 이러한 여러 가지 보철 방식의 단점들을 해결하기 위하여 잔여 시멘트를 남기지 않으면서 연조직 염증을 예방할 수 있는 fiber post 유지형 보철 연결방식을 새롭게 소개하고자 한다.

TECHNICAL APPLICATION OF READY MIXED CONCRETE SLUDGE WATER TO CEMENT MATRIX

  • Moon, Han-Young;Shin, Hwa-Cheol
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.555-559
    • /
    • 2001
  • A by-product, waste sludge water produced from ready mixed concrete(remicon) factories may affect our environmental contamination if it is discharged without proper waste disposal. In Korea, all waste sludge water has been recycled in the way of mixing water of remicon, but the quality of the concrete then produced can be deteriorated, so it might cause slump loss or irregular compressive strength. In this study, waste sludge water is divided into two parts, remicon sludge and residual water in order to make it's property more stable. Then, the remicon sludge and high-alkaline residual water were used as admixture and alkali activator respectively. In this paper we research about quality of with remicon sludge and residual water and performed the fundamental properties of cement matrix mixed with remicon sludge and residual water.

  • PDF

상수도관로중 주철관종의 잔존수명 평가에 관한 연구 (Residual Life Assessment on Cast Iron Pipes of Water Distribution System)

  • 이현동;배철호;홍성호;황재운;곽필재
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

Effect of limestone calcined clay cement (LC3) on the fire safety of concrete structures

  • Gupta, Sanchit;Singh, Dheerendra;Gupta, Trilok;Chaudhary, Sandeep
    • Computers and Concrete
    • /
    • 제29권4호
    • /
    • pp.263-278
    • /
    • 2022
  • Limestone calcined clay cement (LC3) is a low carbon alternative to conventional cement. Literature shows that using limestone and calcined clay in LC3 increases the thermal degradation of LC3 pastes and can increase the magnitude of fire risk in LC3 concrete structures. Higher thermal degradation of LC3 paste prompts this study toward understanding the fire performance of LC3 concrete and the associated magnitude of fire risk. For fire performance, concrete prepared using ordinary Portland cement (OPC), pozzolanic Portland cement (PPC) and LC3 were exposed to 16 scenarios of different elevated temperatures (400℃, 600℃, 800℃, and 1000℃) for different durations (0.5 h, 1 h, 2 h, and 4 h). After exposure to elevated temperatures, mass loss, residual ultrasonic pulse velocity (rUPV) and residual compressive strength (rCS) were measured as the residual properties of concrete. XRD (X-ray diffraction), TGA (thermogravimetric analysis) and three-factor ANOVA (analysis of variance) are also used to compare the fire performance of LC3 with OPC and PPC. Monte Carlo simulation has been used to assess the magnitude of fire risk in LC3 structures and devise recommendations for the robust application of LC3. Results show that LC3 concrete has weaker fire performance, with average rCS being 11.06% and 1.73% lower than OPC and PPC concrete. Analysis of 106 fire scenarios, in Indian context, shows lower rCS and higher failure probability for LC3 (95.05%, 2.22%) than OPC (98.16%, 0.22%) and PPC (96.48%, 1.14%). For robust application, either LC3 can be restricted to residential and educational structures (failure probability <0.5%), or LC3 can have reserve strength (factor of safety >1.08).

치아에 잔존하는 치과재료의 성분분석을 통한 개인식별에의 응용 (Analysis of Residual Dental Materials Existing on the Teeth and Its Application to Individual Identification)

  • 윤중교;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.193-209
    • /
    • 1998
  • In identifying bodies that are severely decayed or damaged, methods using fingerprints and various biochemical tests are known to have its limits. To overcome this, forensic odontological method which is based on the analysis of the cranium, tooth and dental restoration is used to enhance the accuracey of individual identification. For this reason, I have come to analysis of the dental materials that exists between the teeth that is perceived to have been previously restored and the one adjacent to it. By analyzing the constituents of gold crown-restored, non-precious metal-restored, gold inlay-restored and amalgam -restored teeth, and adjacent teeth using EDX(energy dispersive X-ray microanalysis) which was invented to analyze very small amount of elements, the nature of the restoration could be predicted and the results obtained were as follows. 1. Some of constitute of gold alloy was extracted from residual cement of gold crown restoration, but that was not extracted from the restored tooth and the one adjacent to it. 2. Some of constituents of non-precious metal alloy was extracted both in the residual cement on the tooth with no-precious metal restoration and in the tooth with the restoration itself. However, none of its constituents were found in the tooth adjacent to it. 3. Some of constituents of gold alloy were found in the residual cement of gold inlay, but they were not found in the restored tooth and the adjacent tooth. 4. Some of constituents of amalgam alloy were found both in tooth restored with amalgam and in the adjacent tooth. From the results obtained above, it is possible to utilize the data obtained from analyizing residual dental materials in a more effective way. This data compensates for the lost data due to any harm done to the restorations prior to individual identification and further enhances the accuracy. Therefore, it could be concluded that this process of analyzing residual dental materials could be beneficial to individual identification in the area of forensic odontoldogy.

  • PDF

Prediction of mechanical properties of limestone concrete after high temperature exposure with artificial neural networks

  • Blumauer, Urska;Hozjan, Tomaz;Trtnik, Gregor
    • Advances in concrete construction
    • /
    • 제10권3호
    • /
    • pp.247-256
    • /
    • 2020
  • In this paper the possibility of using different regression models to predict the mechanical properties of limestone concrete after exposure to high temperatures, based on the results of non-destructive techniques, that could be easily used in-situ, is discussed. Extensive experimental work was carried out on limestone concrete mixtures, that differed in the water to cement (w/c) ratio, the type of cement and the quantity of superplasticizer added. After standard curing, the specimens were exposed to various high temperature levels, i.e., 200℃, 400℃, 600℃ or 800℃. Before heating, the reference mechanical properties of the concrete were determined at ambient temperature. After the heating process, the specimens were cooled naturally to ambient temperature and tested using non-destructive techniques. Among the mechanical properties of the specimens after heating, known also as the residual mechanical properties, the residual modulus of elasticity, compressive and flexural strengths were determined. The results show that residual modulus of elasticity, compressive and flexural strengths can be reliably predicted using an artificial neural network approach based on ultrasonic pulse velocity, residual surface strength, some mixture parameters and maximal temperature reached in concrete during heating.

Effects of temperature on the evolution of stresses at the stem cement interface

  • Kaci, Djafar Ait;Moulgada, Abdelmadjid;Achache, Habib;Bounoua, Noureddine
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.239-250
    • /
    • 2019
  • The insertion of femoral implants is the most important phase for surgeons, given the characteristics of the cement during its mixing phase, generating residual stresses of thermal origin that increase the different stresses induced in the bone cement. The aim of our study is to determine the different stresses that affect the cement and more particularly at the cement-implant interface for different temperatures, and to make a comparison with the cement at ambient temperature. It was concluded that, there are a large concentration of stresses in the proximal part of the cement. For normal stresses, the bone cement is affected by stresses of tension and compression due to the effect of polymerization and the contraction of the cement.

재유화형 폴리머를 혼입한 폴리머 시멘트 모르타르의 내화특성 (Fundamental Properties Polymer-Modified Mortars Using Re-dispersible Polymer Powder)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.35-41
    • /
    • 2019
  • In this study, the fire resistance performance of polymer cement mortars which are used as a representative repair material for section restoration, is evaluated and residual bond strength is measured by considering unity with concrete. According to the evaluation of fire resistance performance of re-emulsification type polymer cement mortars, residual compressive strength was drastically decreased according to heating temperatures with an increase of polymer addition rate, and this seems to be attributable to the application of polymer film. In addition, an explosion phenomenon occurred frequently with an increase of addition rate, so this should be considered when selecting repair materials and processing.