• Title/Summary/Keyword: Residual Voltage

Search Result 259, Processing Time 0.031 seconds

Study on Electrical Characteristics of Chloromethylated Polyimide

  • Yu, I.H.;Zhong, Z-X;Lee, M.H.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.472-475
    • /
    • 2005
  • The electrical performances of liquid crystal (LC) cells with chloromethylated polyimide (CMPI) alignment layers were investigated. The CMPI layer was previously reported as a multifunctional layer that does role of LC alignment and planarization layer as well as photo-alignment material with high photosensitivity and excellent thermal stability. The capacitance-voltage (C-V) characteristics of LC cells with CMPI alignment layers were measured. Mechanical rubbing of the CMPI layer did not generate much difference in residual DC when compared to commercial PI. However, the LC cell with photo-oxidation CMPI layer shows a high residual DC value and a corresponding low voltage holding ratio (VHR) due to the photo-induced ionic charges on the alignment layer.

  • PDF

A Study on Electrical properties of EPR by Irradiated by X-rays (방사선에 조사된 EPR 의 전기적 특성에 관한 연구)

  • Lee, Sung-Il;Iim, Gui-Yeul;Lee, Ho-Sik;Lee, Hee-Gab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.565-568
    • /
    • 2002
  • The value of charge current, discharge current, $\varepsilon_r$' $\varepsilon_r"$, residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated $CO^{60}\gamma$ ray 0-38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by $CO^{60}-{\gamma}$-irradiation dose The charging current and the discharging current of EPR increase, depending on the ratio of degradation. As the irradiation dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful $CO^{60}-{\gamma}$-irradiation dose. The increase of peak in $\varepsilon_r"$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

Effect of the Co$^{60}$ -Rays due to Electric properties of EPR- (EPR의 전기특성에 미치는 방사선의 영향)

  • 이성일
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.253-259
    • /
    • 2002
  • The value of charge currnet, discharge current, ${\varepsilon}r^'$,${\varepsilon}r^{'}$ residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated C0$^{60}$$\gamma$ ray 0~38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by C0$^{60}$-$\gamma$- irradiation dose. The charging current and the discharging current of EPR increas, depending on the ratio of degradation. As the irradiatin dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful C0$^{60}$$\gamma$- irradiation dose. The increase of peak in ${\varepsilon}r^{'}$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

A Study on the Cut Off Characteristics and Graphite Analysis of Residual Current Protective Devices for Low Voltage (저압용 누전차단기의 차단특성 및 그라파이트 분석에 관한 연구)

  • 최충석;이경섭;정재희;박수홍;김병수;이덕출
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.49-54
    • /
    • 1999
  • In this paper. we studied cut off characteristics and fire hazard of residual current protective devices(RCD or ELB) for low voltage. The operative time of RCD with grounding resistance was analyzed by using RCD operating tester. The surface structure and composition of insulator were analyzed by using scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of phenol resin showed network structure and void. The spectra shown in EDX analysis are composed not only of the corresponding elements but also of several new spectra, as CK. OK$\alpha$. MgK, SiK. and CaK, which were absent in original material.

  • PDF

Characteristics of Lightning Impulse Current of ZnO Block for Transmission Line Arrester with External Gap (송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.458-459
    • /
    • 2007
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

Long Duration Withstand Current Characteristics of ZnO Varistors (ZnO 바리스터 소자의 장시간 방전내량 특성)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Han, Se-Won;Yu, Kun-Yang;Lee, Yong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.544-545
    • /
    • 2005
  • This paper describes the long duration withstand current characteristics of ZnO varistors. Two ZnO varistors were manufactured with general ceramic production methods and three abroad varistors were also prepared to be compared. During long duration withstand test, sample 1 was destroyed at 4th impulse current but the rest passed test. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test results, it is thought that the manufacturing process such as insulating coating, sintering condition and soldering method should be improved.

  • PDF

Inactivation of Zooplankton Artemia sp. Using Plasma Process (플라즈마 공정을 이용한 동물성 플랑크톤 Artemia sp. 불활성화)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • This study aims to inactivate Artemia sp. (Zooplankton) in ballast water through the dielectric barrier discharge (DBD) plasma process. The DBD plasma process has the advantage of enabling direct electric discharge in water and utilizing chemically active species generated by the plasma reaction. The experimental conditions for plasma reaction are as follows; high voltage of 9-22 kV, plasma reaction time of 15-600 s, and air flow rate of 0.5-5.5 L/min. The results showed that the optimal experimental conditions for Artemia sp inactivation were 16 kV, 60 s, 2.5 L/min, respectively. The concentrations of total residual oxidants and ozone generated by plasma reaction increased with an increase of in voltage and reaction time, and the concentration of generated air did not increase above a certain amount.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Disinfection effect and formation characteristics of disinfection by-product at the Electrolyzed Water (전기분해수 살균효과 및 소독부산물 생성 특성 평가)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.547-554
    • /
    • 2013
  • Chlorine has strong oxidizing power, also it is many advantages over other disinfectants such as the residual characteristic and economic feasibility. However, chlorine also has disadvantages such as creating disinfection by-products of chlorine as THMs. In particular, the most deadly disadvantage of chlorine is that it is extremely poisonous toxins about all alive lives. Disinfection with electrolysis water can be a very useful way Because you do not have to worry about chlorine's dangerous. In this study, we evaluated the potential as a disinfectant, across the evaluating disinfection effect and generating characteristic of by-products. The electrolyzed water could be obtained removal efficiencies of over 99.9 % the coliform by operating condition such as residence time, current density (voltage), the electrode gap. The residual chlorine be generated 10,000 mg/L in current density $1.0A/dm^2$ and residence time of 10 minutes. The residual chlorine concentration was possible to maintain a stable. The by-products generated by high concentration residual chlorine in the reactor such as trihalomethanes, haloaceticacid, chloralhydrate, haloacetonitrile were detected in less than a water quality standards. At the concentration of less than residual chlorine of 1 ppm, the chlorine disinfection by-products be generated most below the detection limit.

Study for thermal stability of Liquid Crystal Device (액정 소자의 열적 안전성에 관한 연구)

  • Lee, Sang-Keuk;Hwang, Jeoung-Yeon;Seo, Dae-Shik;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.9-12
    • /
    • 2004
  • In this study, we investigated about electrooptics characteristic of three kind of TN cell on the polyimide surface. Monodomain alignments of thermal stressed TN cell over temperature of liquid crystal isotropic phase were almost same that of no thermal stressed TN cells. However, the thermal stressed TN cell have many defects. Also, threshold voltage and response time of thermal stressed TN cells show same performances of no thermal stressed TN cells. There were little changes of value in these TN cells. However, transmittances of TN cells on the polyimide surface decrease with increasing thermal stress time. Finally, the residual DC voltage of the thermal stressed TN cell on the polyimide surface show decrease of characteristics as increasing thermal stress time. Therefore, thermal stability of TN cell was decreased by high thermal stress for the long times.

  • PDF