• Title/Summary/Keyword: Residual DC voltage

Search Result 51, Processing Time 0.033 seconds

The residual voltage properties of 6.6kV XLPE Cable (6.6kV XLPE Cable의 잔류 전압 특성)

  • Lee, Chang-Hoon;Oh, Jae-Hyung;Wu, Guangning;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1632-1634
    • /
    • 1998
  • In this paper, the study of influence of DC voltage and AC voltage on residual voltage of XLPE Cable was presented. In the former case, when the DC voltage of -10.0[kV] was applied to XLPE Cable for 0, 600, 1200, 1800[sec], time constants were 2139, 1416, 939, 488[sec] and resistivities were 930, 615.65, 408.26, 212.17[${\Omega}{\cdot}m$] respectively. In the latter case, when the AC voltage of 4 and 6[kV] was applied to the same Cable for 600[sec] after applying DC voltage of -5.0[kV] for 600[sec], time constants were 215, 275[sec] and resistivities were 93.48, 119.57[${\Omega}{\cdot}m$] respectively. In this experiments, measurement voltage, charging time and measurement time were -8.0[kV], 30[sec], 600[sec] respectively.

  • PDF

Study on the Quantitativity of Image Sticking in the Fringe-field Switching(FFS) Mode (Fringe-Field Switching (FFS) 모드에서 잔상 정량화에 관한 연구)

  • Seen, Seung-Min;Kim, Mn-Sook;Jung, Yeon-Hak;Kim, Hyang-Yul;Kim, Seo-Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.720-723
    • /
    • 2005
  • We studied the quantitativity of the image sticking which is occured by the resicual DC in the fringe-electric field switching (FFS) mode. Actually, in the FFS mode driven by the strong fringe electric field, the asymmetric residual DC was formed in the bottom substrate. It made the impurity ion stick to the alignment layer such as polyimde layer. Thus, the differnece of the luminance existes after the stress check pattern is applied to the panel so that we can see the image sticking. This image sticking decreases as the residual DC value between specific patterns decreases. Therefore, it is necessary to control the residual DC for the FFS mode with the high image quality. It is possible to eliminate the image stiking when the extra pixel voltage is applied through the circuit tunning for reducing the difference of residual DC accroding to the panel position.

Residual DC characteristic on Twisted Nematic Liquid Display on the Polyimide Surface by the Thermal Stress (열적 stress에 의한 폴리이미드 표면에서의 TN-LCD의 잔류DC 특성)

  • Bae, Yu-Han;Hwang, Jeoung-Yeon;Kim, Jong-Hwan;Mun, Hyun-Chan;Han, Jung-Min;Kim, Young-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.498-501
    • /
    • 2004
  • In this study, the threshold voltage and the response time of thermal stressed TN-LCDs showed the same performances on no thermal stressed TN-LCDs. There was little change of value in TN cells. Also, the transmittances of TN-LCDs on the rubbed PI surface were almost same while increasing thermal stress time. However, the thermal stability of TN cell was decreased by the high thermal stress for the long duration. Residual DC was decreased as the thermal stress increases. Especially, when TN cell was stressed more and more by heating, residual DC was changed a lot. As a result, the residual DC property of LCD in projection TV is affected very much by heating.

  • PDF

A Study on Electro-Optical Characteristics of the Ion Beam Aligned TN Cell on the DLC Thin Film (DLC 박막을 이용한 Ion Beam 배향 TN 셀의 전기광학특성에 관한 연구)

  • 황정연;조용민;노순준;이대규;백홍구;서대식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.726-730
    • /
    • 2002
  • Electro-optical (EO) performances of the ion beam (IB) aligned twisted-nematic (TN)-liquid crystal display (LCD) with ion beam exposure on the new diamond-like carbon (DLC) thin film surface were investigated. A good voltage-transmittance (V-T) curve of the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min was observed. Also, the fast response time of the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved. Finally, the residual DC voltage of the ion beam aligned TN-LCD on the DLC thin film surface is almost the same as that of the rubbing aligned TN-LCD on a polyimide (Pl) surface.

Study on thermal and UV stability of Liquid Crystal Display for Projection TV Application (프로젝션 TV 적용을 위한 액정 디스플레이의 열적 및 UV 안전성에 관한 연구)

  • Choi, Sung-Ho;Hwang, Jeoung-Yeon;Bae, Yu-Han;Lee, Whee-Won;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.287-288
    • /
    • 2005
  • In this study, we have investigated electro-optical characteristics of thermal and UV stressed TN cells on the rubbed polyimide surface. Mono-domain alignments of thermal stressed TN cells over temperature of liquid crystal isotropic phase were almost same that of no thermal stressed TN cells. Also, threshold voltage and response time of thermal stressed TN cells were same that of no thermal stressed TN cells. Finally, the residual DC voltage of the thermal stressed TN cell on the polyimide surface show decrease of characteristics as increasing thermal stress time. Therefore, thermal stability of TN cell was decreased by high thermal stress for the long times.

  • PDF

Study for Thermal Stability of Liquid Crystal Device (액정 소자의 열적 안전성에 관한 연구)

  • 이상극;황정연;서대식;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.439-442
    • /
    • 2004
  • In this study, we investigated about electrooptics characteristic of three kinds of TN cell on the polyimide surface. Monodomain alignments of thermal stressed TN cell over temperature of liquid crystal isotropic phase were almost the same as that of no thermal stressed TN cells. However, the thermal stressed TN cells have many defects. Also, threshold voltage and response time of thermal stressed TN cells show the same performances as no thermal stressed TN cells. There were little changes of value in these TN cells. However, transmittances of TN cells on the polyimide surface decrease with increasing thermal stress time. Finally, the residual DC voltage of the thermal stressed TN cell on the polyimide surface shows decrease of characteristics as increasing thermal stress time. Therefore, the thermal stability of TN cell was decreased by high thermal stress for the long times.

Effect of Carbon Nanotube Concentrations on Residual DC of a Twisted Nematic Liquid Crystal Cell (탄소 나노 튜브 함량에 따른 TN 액정 셀의 잔류 DC 연구)

  • Baik, In-Su;Park, Kyung-Ah;Jeon, Sang-Youn;An, Kay-Hyeok;Lee, Seung-Hee;Lee, Young-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.297-298
    • /
    • 2005
  • We have fabricated twisted nematic (TN) liquid crystal cells doped by carbon nanotubes (CNTs) with different CNT wt. %. With a minute amount doping, multi-walled CNTs did not perturb the liquid crystal orientations at the off- and on-state. The hysteresis studies of voltage-dependent capacitance (V-C) under the influence of electric field generated by ac and dc voltage show that the residual do, which is tightly related to image sticking problem in liquid crystal displays, is greatly reduced due to ion trapping by CNTs. Also, the V-C hysteresis shows dependency of capacitance on concentration of multi-walled CNTs.

  • PDF

Study on Electrical Characteristics of Chloromethylated Polyimide

  • Yu, I.H.;Zhong, Z-X;Lee, M.H.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.472-475
    • /
    • 2005
  • The electrical performances of liquid crystal (LC) cells with chloromethylated polyimide (CMPI) alignment layers were investigated. The CMPI layer was previously reported as a multifunctional layer that does role of LC alignment and planarization layer as well as photo-alignment material with high photosensitivity and excellent thermal stability. The capacitance-voltage (C-V) characteristics of LC cells with CMPI alignment layers were measured. Mechanical rubbing of the CMPI layer did not generate much difference in residual DC when compared to commercial PI. However, the LC cell with photo-oxidation CMPI layer shows a high residual DC value and a corresponding low voltage holding ratio (VHR) due to the photo-induced ionic charges on the alignment layer.

  • PDF

A Study on Performance Enhancement of Distance Relaying by DC Offset Elimination Filter (직류옵셋제거필터에 의한 거리계전기법의 성능 개선에 관한 연구)

  • Lee, Kyung-Min;Park, Yu-Yeong;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • Distance relay is widely used for the protection of long transmission line. Most of distance relay used to calculate line impedance by measuring voltage and current using DFT. So if there is a computation error due to the influence of phasor by DC offset component, due to excessive vibration by measuring line impedance, overreach or underreach can be occurs, and then abnormal and non-operation of distance relay can be issue. It is very important to implement the robust distance relaying that is not affected by DC offset component. This paper describes an enhanced distance relaying based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any prior information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced distance relay uses fault current as well as residual current. The behavior of the proposed distance relaying using off-line simulation has been verified using data about several fault conditions generated by the ATP simulation software.

Residual Insulation characteristics of long-term serviced 6.6 kV CV Cable (6.6kV 철거 CV 케이블의 잔존 절연 특성)

  • 백주흠;김동욱;한기만
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.46-49
    • /
    • 1994
  • In order to investigate possibility of CV cable diagnosis technique, residual insulation characteristics of .long - term serviced 0.6 kV CV Cable are examined by DC leakage current residual voltage tensile strength, cross1inking density and AC & impulse breakdown. Also effect of cable structure and water tree are reported

  • PDF