• Title/Summary/Keyword: Residential water

Search Result 465, Processing Time 0.028 seconds

Development of a Hydrologic System for Simulating Daily Water Storage in an Estuary Reservoir

  • Noh, Jae-Kyoung
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.1-10
    • /
    • 2003
  • In order to analyze the water supply capacity in an estuary reservoir, a system composed of daily water balance model and daily inflow model was developed. The agricultural water demands to paddy fields, domestic water demands to residential areas, and industrial water demands to industrial complexes were considered in this daily water balance model. Likewise, the outflow volume through sluice gates and inside the water level at the start of the outflow was initially conditioned to simulate estuary reservoir storage. The DAWAST model (Noh, 1991) was selected to simulate daily estuary reservoir inflow, wherein return flows from agricultural, domestic, and industrial water were included to simulate runoff. Using this system, the water supply capacity in the Geum River estuary reservoir was analyzed.

Waterborne viruses in drinking water in Korea: survey 1999 for enteric virus contamination in treated water and its source water

  • Rhie KT;Yoon JD;Chung HM;Kim HS;Jeong YS
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.142-142
    • /
    • 2001
  • A national survey for enteric virus contamination in treated water and its source water was performed from March to November 1999. The water samples were subjected to virus filtration at the major water plants producing over 10$^5$ tons treated water per day. Twenty surveyed sites encompass most of heavily populated residential area except for Seoul and Pusan. (omitted)

  • PDF

Optimization for the Humidification Performance of a Residential Rotor-Type Humidifying Element (가정용 로터식 가습 소자의 가습 성능 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.7-13
    • /
    • 2017
  • A comfortable indoor environment is important considering that many hours are spent in residential or office space. A humidifier is used to control the indoor humidity. In particular, an element type humidifier has the advantage of a simple structure and low energy consumption. Two types of humidifiers - stationary or rotor - are commonly used for residential purposes. In this study, performance optimization was conducted for a rotor-type humidifying element used in a residential humidifier. The optimization included the rotation speed, water submersion depth, etc. The test range consisted of an open area to the air from 57 to 90%, rotation speed from 0.2 to 2.0 rpm, frontal air velocity from 0.5 to 2.5 m/s. The results showed that the optimal open area to air was 70%. On the other hand, the effects of the rotation speed on the moisture transfer rate was negligible. On the other hand, the pressure drop increased with increasing rotation speed. As the frontal air velocity increased, both the moisture transfer rate and pressure drop increased. The humidification capacity of the present element was 0.08 ~ 0.31 kg/hr. A comparison of the data with the theoretical results was made.

A study on the Occupants' Apprasials of Newly Consturcted Apartment (신축 공동주택의 주거환경에 관한 입주자 평가)

  • 임인순
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.73-83
    • /
    • 1993
  • Recently, large APT complexes are newly constructed in Taegu city and among them, large APT complexes aggegate densly espically in Weolsung and Jisan complexes of Dalsuh-gu and Susung-gu districts. The purpose of this thesis is to perform occupants' apprasials about residential environment on the housewifes residing at new constructed APT who seem tn have different apprasials on the residential environment by the zones. The results of the investigations are as follows. 1. House possessed type and house sire got elevated in comparison with them before shifting residence in respect to residential property and it was revealed they moved to short distance in the change of their lands. And most occupants could choose their houses by looting-out and there's some difference in the choice motive according to the zones. 2. As a result of studying the relation between demographic and residential properties, there were deep differe-nces in the Possessed house type before move, possessed house size after move, preferenti-al degree of house and move plan. 3. In the degree of satisfaction on residential environment, the result was high in the order of heating facilities, water-supply and draining facilities and lighting and was low in the order of room's size, interior decoration and soundproofin. According to zones, there was a great difference in the items of room's size, privacy, heating facilities, securi-ty from calamity, ventilation, convenience of traffic and school group and facilities for extracurricular activities and the degree of satisfaction was high in Jisan zone in othe items except for room's size and heating facilities. 4. In the tenants' apprasials on tile inside and outside spaces of the zones, important factors were "Cultural Institutions", "Green Areas", "Level of Welfare Facilities" and "Utility degree of welfare facilities" and in the classification of important factors according to the zones, the first and the third factors were changed each other. I think this is because they attached importance to somethings dissatisfied in present circumstances.

  • PDF

Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions (국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석)

  • Yu, Byeong Ho;Seo, Byeong-Mo;Moon, Jin-Woo;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

A Study on Power Trading Methods for in a Hydrogen Residential Model (수소주거모델의 전력 거래 참여 방안 고찰)

  • KISEOK JEONG;TAEYOUNG JYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.

The Analysis of Public Water Demand (생활용수 수요 분석)

  • Min, Dong Ki
    • Environmental and Resource Economics Review
    • /
    • v.9 no.2
    • /
    • pp.311-332
    • /
    • 2000
  • The main aim of this paper is to estimate the change in the quantity demanded of public water when the economic factors such as income and water price are changed. The privious methods to estimate the quantity of public water demanded has been usually based on the LPCD(liter per capita per day). Implicitly, this method regards the price of water as given. If the water price and income elasticities of water demand are estimated using the time-series and pooled data analysis. In the second step, the quantity demanded of public water are forecasted using the estimated elasticities. The results show that we can reduce the quantity demanded of residential water considerably when the water price is changed.

  • PDF

Patent Analysis on Fuel Cell By-Product Utilization Technology for Operating Expenditure Reduction of Hydrogen Residential Buildings (수소에너지 주거건물의 운영비용 감축을 위한 연료전지 발전 부산물 활용기술에 관한 특허분석)

  • Ji, SangHoon;Kim, WeonJae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.488-493
    • /
    • 2020
  • The demand for hydrogen, which is considered an environmentally friendly energy source, is increasing, and at the same time, the fuel cell market is increasing continuously. This study aimed to establish a strategy for securing intellectual property rights on fuel cell by-product utilization technology for operating expenditure reduction of hydrogen-powered residential buildings. In this patent analysis, this study investigated Korean, American, Japanese, and European patents filed/published/registered by October 2019 and established a technical classification system and classification criteria through expert discussion. To reduce the operating expenditure of hydrogen-powered residential buildings, intellectual property rights will be improved using systems and methodologies involving cathode-side purified air, product water, and oxygen-depleted air captured with the dead-end mode operation of polymer electrolyte fuel cells.

A Study on the Optimum Application Method of Solar Thermal System to reduce Thermal Load and Carbon Emission in Apartment Building (공동주택의 열부하 및 탄소배출량 저감을 위한 태양열시스템의 최적 적용 방안 연구)

  • Yoon, Jong-Ho;Sim, Se-Ra;Shin, U-Cheul;Baek, Nam-Chun;Kwak, Hee-Yul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.135-142
    • /
    • 2011
  • Architectural market in the world is trying to develop Zero Carbon Buildng that doesn"t use fossil fuel. Residential building that thermal load such as heating and domestic hot water is over 70% in energy consumption is easy to make Zero Carbon Building compared with office building that is mainly electric load. So, As a preliminary for analyzing the effect of Solar thermal system in the building, an annual energy consumption of residential building and total heat loads are calculated. Based on this result, three alternatives of solar thermal system for hot water and heating are applied in the building while installation area is increasing. Solar thermal system is applied on balcony and roof of apartment building as the way to reduce thermal load. In the first case that solar thermal system for hot water is applied on the balcony, optimum installation area is $56m^2$. And you could install $40m^2$ of this system in the roof that angle is $30^{\circ}$. In the second case of solar thermal system for heating and hot water, you can install $40m^2$ on the roof. As a result of economic evaluation, the most economical application method is to install $40m^2$ of solar thermal system for only hot water on the roof of the building. At that time, you can payback the initial investing cost within 10 years. And carbon emission of this method can be reduced until about 4 ton per year.