• Title/Summary/Keyword: Residential water

Search Result 467, Processing Time 0.029 seconds

Characteristics of Chromium, Copper, and Arsenic Leaching from CCA-Treated Wood (CCA 방부처리 목재로부터 크롬, 구리 및 비소의 용탈 특성)

  • Kim, He-Kap;Kim, Dong-Jin
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.4
    • /
    • pp.339-348
    • /
    • 2007
  • A laboratory experiment was conducted to study the characteristics of leaching of Cr, Cu, and As from chromated topper arsenate (CCA)-treated wood. The wood species tested was hemlock spruce ($10\;cm\;{\times}\;10\;cm\;{\times}\;10\;cm\;tube$). The leaching experiment was conducted over 60 days using I L of leachants whose pHs were adjusted to 2.0, 3.7, and 1.6, respectively with nitric acid, and also using lake water, according to the OECD guideline. Each leachate was analyzed for Cr and Cu using flame-AAS, and for As using vapor generation-AAS. Three metals were loathed at the highest levels at pH 2.0 but almost at similar levels at the other conditions. Cumulative quantifies over 60 days of a leaching period were in order of As>Cu>Cr. As was predicted to leach with an increase in flux over a 10 year period, while Cr and Cu fluxes were predicted to decrease with time. This result suggest that arsenic can pose a health risk to humans over a long period of time, when CCA-treated wood is used for building facilities (e.g., playgrounds, residential purposes, etc.) with which humans frequently contact.

The Classification and Characteristics of Landscape on Urban Land Use Patterns - The Case of Metropolitan Daejeon - (도시의 토지이용 형태별 경관특성과 유형 - 대전광역시를 사례로 -)

  • Kim Dae-Hyun;Kim Dae-Soo;Joo Shin-Ha;Oh Se-Rae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.1-10
    • /
    • 2005
  • Recently, as urban landscape is growing in importance, urban landscape planning is being actively performed. for this purpose, classification of the urban landscape is definitely required. Therefore, this research focuses on classifying urban landscape in Daejeon metropolis by dividing the urban land use pattern. This results are as follows. 1. Urban land use pattern is divided into 20 classes. The residential, commercial and industrial areas, the old market and the bus terminal are evaluated negatively, whereas the areas of school, water reservoir, neighborhood park and train station are appreciated as being positive in landscape characters. 2. As a result of a cluster analysis, urban landscape has five different landscape types. These are: landscapes of medium diversity lacking green area, landscapes of high diversity lacking green area, landscapes rich in green area and with medium diversity, landscapes rich in green area and with high diversity, and landscapes rich in green area and with low diversity. 3. In landscape characters of beauty and harmony, landscapes rich in green area and with medium diversity are more positively evaluated than those rich in green area and with low diversity. This point should be taken into account for planning the urban landscape.

A Comparative Study on Office Building Criteria between G-SEED and LEED

  • Mok, Seon-Soo;Cho, Dong-Woo;Park, Ah-Reum
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 2014
  • G-SEED aims for establishing green environmental building with energy saving and has started for evaluating with multi-residential complex in 2002 by the Ministry of Land, Infrastructure & Transport (MOLIT) and the Ministry of Environment to develop the current 10 building types and new & existing building types to be applied. Since G-SEED has been developed for more than 10 years, the strategy of globalization is needed with constant review itself and comparison between other assessments to understand current situation from the global perspectives. This study draws similarities and differences of G-SEED and LEED criteria by the comparison from re-constructed LEED criteria based on G-SEED. "Energy & Pollution" is the most concerned category in both assessments as the result of analysis on category rates. Next concerns are "Material & Resources", "Indoor Environment" and "Water Management". The unique categories in both criteria are "Ecological Environment" in G-SEED and "Innovation & Design Process" in LEED. The conclusion of this research is that two assessments are organized at different locations and with different strategies for developing green building but there are common concerns such as energy saving, material use, indoor environment. As a result, it is expected to use fundamental data for developing G-SEED for global standard.

A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test (태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구)

  • Kim, Mi-Yeon;Choi, Byung-Do;Kim, Hyung-Geun;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

A Study on the Heat Pump-Latent Heat Storage Type (열펌프-잠열축열 온돌 시스템 연구)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

The hybrid heat pump with solar energy for heating (태양열이용 하이브리드 난방 열펌프시스템)

  • Kim, Ji-Young;Ko, Gwang-Soo;Kang, Byung-Chan;Park, Youn-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.173-178
    • /
    • 2005
  • Recently. we interested in renewable energy due to cost increase of the crude oil, etc. In this study solar assisted hybrid heat pump system that uses the solar heat and air as heat source analyzed by experimentally.'rho system could runs at dual mode. One is thermal storage mode of solar energy at day time and the other is heat pump mode with low temperature air as heat source at night time. In case of setting temperature over the limited range. high temperature water heated at the solar energy collecting tubes supplied to the storage tank. As results. it is founded that the heat pump performance Is higher than general heat pump which using the only air as a heat source. The developed system could be used as main healing equipment for the panel heating for the residential house.

  • PDF

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

Dense Downtown vs. Suburban Dispersed: A Pilot Study on Urban Sustainability

  • Wood, Antony;Du, Peng
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.113-129
    • /
    • 2017
  • This paper presents the initial findings of a ground-breaking two-year CTBUH-funded research project investigating the real environmental and social sustainability of people's lifestyles in a number of high-rise residential towers in downtown Chicago, and a comparable number of low rise homes in suburban Oak Park, Chicago - based on actual energy bills and other real data. The study is ground-breaking because, to date, similar studies have been mostly based on very large data sets of generalized data regarding whole-city energy consumption, or large-scale transport patterns, which often misses important nuances. This study has thus prioritized quality of real data (based on around 250 households in both high rise and low rise case studies), over quantity. In both urban and suburban cases, the following factors have been assessed: (i) home operational energy use, (ii) embodied energy of the dwelling, (iii) home water consumption, (iv) mobility and transport movements, (v) urban/suburban Infrastructure, and (vi) quality of life. The full results of this seminal study will be published in the form of a CTBUH Research Report publication in 2017. Presented below is an overview of the initial (and, currently, unverified) findings of the research, together with the limitations of the study that should be taken into account, as well as future plans for developing this important pilot study.