• Title/Summary/Keyword: Residential water

Search Result 467, Processing Time 0.033 seconds

Analysis of the Linkage Effect by Component Technology in Low Impact Development Facilities (저영향개발 시설의 요소기술별 연계 효과 분석)

  • Baek, Jongseok;Lee, Sangjin;Shin, Hyunsuk;Kim, Jaemoon;Kim, Hyungsan
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.35-42
    • /
    • 2019
  • Urbanization has led to extreme changes in land use on urban watersheds. Most cities are becoming residential, commercial and industrial areas, making infiltration and storage of rainfall less favorable. The demand for LID (Low Impact Development) technology is increasing in order to mitigate this water cycle distortion and return to existing hydrological conditions. The LID technique is effective in reducing runoff by permeating the urban impervious area. However, considering the limit of the installation area and the financial requirement of the installation, there is not much research on the linkage of each LID component technology for optimum efficiency according to the appropriate scale. In this study, the effects of the LID facilities applied to the target site were simulated using the SWMM model, suggesting the optimal linkage method considering interconnectivity, and applying the effects as an existing installation of individual facilities. The water balance at the time of application of the LID technology, short-term and long-term rainfall event were compared. Also, the individual application and the linkage application were compared with each other. If each component technology has sufficient processing size, then linkage application is more effective than individual application.

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

A Study on the Conservation, Rehabilitation and Creation of Naturality of Rivers(I) - The Correlation of the degree of Pollution on a River and the Land Use in Rural Area - (하천에 있어서 자연성의 보전, 정비, 창출에 관한 연구(I) - 농촌지역에서의 토지이용과 하천수질과의 상관성 -)

  • Lee, Jin-Hee;Lee, Haeng-Youl;Lee, Jae-Kun;Lee, Dong-Kun;Kim, Hoon-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.1 no.1
    • /
    • pp.84-94
    • /
    • 1998
  • The sources of the pollution on a river are divided into two classes, one the point source and the other non-point source. In raining, especially, the non-point source discharged from paddy, residential area, road ${\cdots}$ etc have correlations with the land use. This study was carried out to find out the model to estimate the quality of water in a river according to the land use. Land use data (Pungse-Myeoun and Kwangduk-Myeoun in Chonan) were produced from Landsat TM (Thematic Mapper) and topographic map. Total nitrogen(TN) and total phosphorus(TP) general indices for the degree of pollution in river were measured during 11 months. Correlations between two variables(Land use and Pollutants(TN, TP)) were explained by the regression coefficient. As a result of this study, we found that among the five types of land use, the residential area, store area and paddy have significant effects upon the quality of water in a river. The results of this study will be applied to pre-estimate the degree of pollution in river broadly and to offer basic data in establishing the land use plan and the concept on the conservation of the river in rural area.

  • PDF

Mutagenicity of River Water of Nakdong River Estuary in Korea (낙동강 하구수의 변이원성에 대한 연구)

  • ;;Ryuich Otsu
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The mutagenicity of the river water of Nakdong river estuary was determined by Ames test using the blue rayon suspension method. Samples were collected from 10 sites in the estuary once in each season of 1998. The samples collected from the sites where industrial waste discharge on May were mutagenic, but the other samples were not mutagenic. The sample collected from the site 1 located near the industrial area (Hadan-dong) were highly mutagenic in the TA98 with (+S9) and without (-S9) mix as well as in the TA100 with (+S9) and without (-S9) S9 mix, suggesting that the river water of this site is polluted by direct and indirect mutagens of frame-shift type as well as direct and indirect mutagens of base-replacement type. The positive mutagenicity, although relatively low, was also detected in TA98 with (+S9) and without (-S9) S9 mix in the extract of the site 4 near the industrial area(Jangrim-dong), suggesting that the primary mutation type is frame-shift. The negative mutagenicity from July to December at the sites (1-4) near the industrial area seems to be affected by the low economic growth rate in 1998 in Korea. On the other hand, the negative mutagenicity in all extracts collected from the sites 5-10 near the residential area where living sewage discharge, suggests that the river water was not polluted by mutagens.

  • PDF

Assessing the Spatial Distribution of Perfluorooctanoic Acid Exposure via Public Drinking Water Pipes Using Geographic Information Systems

  • Vieira, Veronica;Hoffman, Kate;Fletcher, Tony
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.9.1-9.5
    • /
    • 2013
  • Objectives Geographic Information Systems (GIS) is a powerful tool for assessing exposure in epidemiologic studies. We used GIS to determine the geographic extent of contamination by perfluorooctanoic acid, C8 (PFOA) that was released into the environment from the DuPont Washington Works Facility located in Parkersburg, West Virginia. Methods Paper maps of pipe distribution networks were provided by six local public water districts participating in the community cross-sectional survey, the C8 Health Project. Residential histories were also collected in the survey and geocoded. We integrated the pipe networks and geocoded addresses to determine which addresses were serviced by one of the participating water districts. The GIS-based water district assignment was then compared to the participants' self-reported source of public drinking water. Results There were a total of 151,871 addresses provided by the 48,800 participants of the C8 Health Project that consented to geocoding. We were able to successfully geocode 139,067 (91.6%) addresses, and of these, 118,209 (85.0%) self-reported water sources were confirmed using the GIS-based method of water district assignment. Furthermore, the GIS-based method corrected 20,858 (15.0%) self-reported public drinking water sources. Over half (54%) the participants in the lowest GIS-based exposure group self-reported being in a higher exposed water district. Conclusions Not only were we able to correct erroneous self-reported water sources, we were also able to assign water districts to participants with unknown sources. Without the GIS-based method, the reliance on only self-reported data would have resulted in exposure misclassification.

Effect of Reducing Squeal Noise at Railway of Curve Section by using the Watering (살수를 이용한 철도곡선구간 스퀼소음 저감효과에 관한 연구)

  • Ji, Hae-Young;Koo, Dong-Hoe;Jeon, Seung-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2928-2933
    • /
    • 2011
  • The urban railway has been planned not only the subway, but also the elevated railway in Seoul, South Korea. Therefore, it is steadily increasing civil complaints for railway noise passing through that residential district. In this paper, we focused on noise of squeal characteristics induced by interaction between railway vehicle's wheel and rail. Then we selected the point that carried out scattering water droplet to the rail and compared the noise level of the watering test results before and after. Scattering water test results showed that level of the noise reduced intermittently occurring high frequency characteristics of squeal noise as well as overall noise level. In the future, we will apply the sensor to the sprinkling system for noise reduction where the place of existing squeal noise is, and make a suggestion of this solution will be more economical, environmental-friendly, and appropriate to reduce the squeal noise occurred by railway vehicle than others.

  • PDF

Strategy of Energy Saving and Thermal Environment Improvement for Intermittent Heating System in Apartment Buildings (공동주택 간헐난방시스템의 에너지 절감 및 열환경 개선방안 연구)

  • Ahn Byung-Cheon;Lee Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.88-93
    • /
    • 2005
  • In this study, the operational characteristics on heating performance and energy consumption for intermittent hot water heating system in apartment buildings were research by simulation. The effects of apartment inlet hot water temperature and operation time per day on energy consumption and indoor thermal environment are investigated. The strategy of energy saving and thermal environment improvement is suggested in comparison with the existing ones.

Heavy metals and VOCs contamination of urban Broundwaters in Seoul, Korea

  • Park, Seong-Sook;Yun, Seong-Taek;Park, Byoung-Young;Yu, Soon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.291-295
    • /
    • 2002
  • We measured the concentrations of heavy metals and VOCs in groundwaters (N=38) in Seoul. The comparison of our data with U.S. Environmental Protection Agency's Maximum Contaminant Levels for Drinking Water and with the Korean Drinking Water Standards shows that most of the metals except for Fe and Mn do not exceed the levels. However, the concentrations of most heavy metals (esp., Zn, Cu, Cr, Ni) tend to increase in residential and industrialized areas. The examination of the metal speciation using Anodic Stripping Voltammetry (ASV) and TOC analyzer Indicates that large amounts of Zn occur as labile metal fraction, whereas Cu occurs as non- labile forms at many sites, possibly due to its tendency to be adsorbed onto inorganic colloidal particles to form electroinactive species in groundwater. The most frequently existed VOCs in Seoul groundwaters are trichloroethylene and tetrachloroethylene, especially in agricultural, industrial, and high traffic areas.

  • PDF

Experimental Study for Horizontal Geothermal Heat Pump Heating Performance Analysis (수평형 지열 히트펌프 난방 성능 분석을 위한 실험적 연구)

  • Ihm, Pyeong chan;Cho, Sung woo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.2
    • /
    • pp.7-12
    • /
    • 2016
  • This study have an objective to suggest basic data and measured result of heating performance on water-water type horizontal geothermal heat pump which is based on heating and cooling load calculation result of small residential house. The average temperature during measured periods is $9.4^{\circ}C$ on primary EWT and is $7.6^{\circ}C$ on primary LWT. The temperature difference shows $1.8^{\circ}C$ as average temperature. Because the average outdoor temperature of peak is lager than on December and than on January, the temperature difference between EWT and LWT is bigger that on January than that on December. The system COP is 3.62.

Monitoring Study on Groundwater Quality of an Alluvial plane in the North Han River Basin (북한강 수계 충적평야의 지하수 수질 모니터링 연구)

  • Choi, Joong-Dae;Jang, Seok-Oh;Kim, Do-Hwan;Choi, Byung-Yong;Choi, Kyoung-Jin;Park, Ji-Sung;Yoo, Sun-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.747-752
    • /
    • 1999
  • The effects of nonpoint source pollutants from a small agricultural alluvial watershed on groundwater quality were investigated and analyzed in this study . Water quality factors of pH, electric conductivity(EC), total nitrogen(T-N), nitrate nitrogen(NO3-N), ammonium nitrate(NH4-N), and total phosphorus(T-P) concentrations were monitored at the watershed located in Shinbook-myon , Chunchon, Kangwon-Do, Korea for 2 years. Groundwater samples of about 2 liters from 7 to 20 farm wells were regulary collected and analyzed with respect to the water quality factors which were again anlayzed with respect to time and land uses of residential , agricultural , livestock feedlot, greenhouse, and natural areas.

  • PDF