• 제목/요약/키워드: Residential environment analysis

검색결과 764건 처리시간 0.024초

Sources of Carbonaceous Materials in the Airborne Particulate Matter of Dhaka

  • Begum, Bilkis A.;Hossain, Anwar;Saroar, Golam;Biswas, Swapan K.;Nasiruddin, Md.;Nahar, Nurun;Chowdury, Zohir;Hopke, Philip K.
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.237-246
    • /
    • 2011
  • To explore the sources of carbonaceous material in the airborne particulate matter (PM), comprehensive PM sampling was performed (3 to 14 January 2010) at a traffic hot spot site (HS), Farm Gate, Dhaka using several samplers: AirMetrics MiniVol (for $PM_{10}$ and $PM_{2.5}$) and MOUDI (for size fractionated submicron PM). Long-term PM data (April 2000 to March 2006 and April 2000 to March 2010 in two size fractions ($PM_{2.2}$ and $PM_{2.2-10}$) obtained from two air quality-monitoring stations, one at Farm Gate (HS) and another at a semi-residential (SR) area (Atomic Energy Centre, Dhaka Campus, (AECD)), respectively were also analyzed. The long-term PM trend shows that fine particulate matter concentrations have decreased over time as a result of government policy interventions even with increasing vehicles on the road. The ratio of $PM_{2.5}/PM_{10}$ showed that the average $PM_{2.5}$ mass was about 78% of the $PM_{10}$ mass. It was also found that about 63% of $PM_{2.5}$ mass is $PM_1$. The total contribution of BC to $PM_{2.5}$ is about 16% and showed a decreasing trend over the years. It was observed that $PM_1$ fractions contained the major amount of carbonaceous materials, which mainly originated from high temperature combustion process in the $PM_{2.5}$. From the IMPROVE TOR protocol carbon fraction analysis, it was observed that emissions from gasoline vehicles contributed to $PM_1$ given the high abundance of EC1 and OC2 and the contribution of diesel to $PM_1$ is minimal as indicated by the low abundance of OC1 and EC2. Source apportionment results also show that vehicular exhaust is the largest contributors to PM in Dhaka. There is also transported $PM_{2.2}$from regional sources. With the increasing economic activities and recent GDP growth, the number of vehicles and brick kilns has significantly increased in and around Dhaka. Further action will be required to further reduce PM-related air pollution in Dhaka.

주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정 (Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses)

  • 양원호;임성국;손부순
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

특정지역에서 토양중 PCB의 분석과 인체노출량평가 (Quantiflcation of Human Exposure and Analysis of PCBs in Contaminated Some Site)

  • 이효민;박송자;김명수;윤은경;최시내;김선태;박종세
    • Toxicological Research
    • /
    • 제13권1_2호
    • /
    • pp.49-54
    • /
    • 1997
  • PCBs are classified as B2 (Probable human carcinogen) based on the induction of hepatocellular carcinomas in rats and mice from IRIS (Integrated Risk Information System). About 20 years ago, PCBs were phased out for electrical use in Korea, but PCBs were continuously used in the other field. Lately, there has been increasing concern on possible effects of contaminated soil to the other environment and human health. The purpose of this study is to determine PCBs level in soil at some site and to assess the human exposure doses according to exposure routes for people living within sites which expected to be exposed to PCBs. Pollution level of PCBs on the site was monitored using gas liquid chromatography. To assess the transport of PCBs in soil to plant and to air, various transfer factors(diffusion coefficient, bioconcentration factor etc.) were considered in simple calculations. To calculate the residential exposure doses by routes, some equations were considered using assumption value, which define inhalation, ingestion (soil, plant) and derreal uptake pathway. Computated results will be used as risk assessment information for human health evaluation on contaminated soil.

  • PDF

주거용 건축물의 실내 라돈농도 경감방안에 관한 연구(I) -Test Cell Study (A Study on Mitigation Methods of Indoor Radon Concentration in Residential Buildings(I) - Test Cell Study)

  • 차동원
    • KIEAE Journal
    • /
    • 제1권2호
    • /
    • pp.21-28
    • /
    • 2001
  • Naturally-ocurring short-lived decay products of radon gas in indoor air are the dominant source of ionizing radiation exposure to the general public. It is written in BEIR VI Report(l999l the radon progeny were identified as the second cause of lung cancer next to cigarette or 10 % to 14 %(15,400 to 21,800 persons p.a.) of all lung cancer deaths in USA. Indoor radon concentrations in houses typically result from radon gaining access to houses mainly from the underlying soil. In the States, they have "Indoor Radon Abatement Act" which was converted from "Toxic Substance Control Act" in 1988 to establish the national long-term goal that indoor air should be as free of radon as the ambient air outside of buildings. To review and study techniques for controlling radon, two test cells were constructed for a series of tests and are under measuring indoor and soil gas (underneath of floor slab)radon concentrations according to EPA's measurement protocol. In this paper, important theoretical studies are previewed and the following paper will explain the test results and confirm the theories reviewed to find out suitable coefficients. On the basis of test analysis, it will be described and evaluated various techniques that can be used to mitigate elevated indoor concentration of radon including the control of radon and its decay products.

  • PDF

물류수송을 위한 이종 협업 무인 시스템 개발 (Development of a Cooperative Heterogeneous Unmanned System for Delivery Services)

  • 조성욱;이다솔;정연득;이웅희;심현철
    • 제어로봇시스템학회논문지
    • /
    • 제20권12호
    • /
    • pp.1181-1188
    • /
    • 2014
  • In this paper, we propose a novel concept foran unmanned delivery service using a cooperative heterogeneous unmanned system consisting of a self-driving car and an unmanned aerial vehicle (UAV). The proposed concept is suitable to deliver parcels in high-density and high-rise urban or residential areas. In order to achieve the proposed concept, we will develop acooperative heterogeneous unmanned system. Customers can order goods using a smartphone application and the order information, including the position of the customer and the order time, and the package is transported automatically by the unmanned systems. The system assigns the tasks suitable for each unmanned vehicle by analyzing it based on map information. Performance is validated by experiments consisting of autonomous driving and flight tests in a real environment. For more evaluation, the landing position error analysis is performed using circular error probability (CEP).

공공분양과 임대 아파트 거주자들의 커뮤니티 의식과 커뮤니티 공간 이용 행태 비교 연구 (The Comparative Study on the Community Consciousness and Community Facility Using Behavior of the Condominium and the National Rental Housing)

  • 박재현;강순주
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2009
  • This study was motivated by the fact that the current tendency of social integration in apartment complex is not fully performed its functions as a recovery from the community. The purpose of the study is to provide basic data to be useful for living environment of apartment complex, through comparative analysis of residential conditions, community consciousness, and community facility using behavior of residents in national rental housing and condominium. The results are as follows. 1) Condominium's residents have high level of community consciousness compare to the national rental's. Even though both targets were generally above the average, housing and construction standard are required to reconsider for the enhancing of community consciousness of residents. 2) To activate the use frequency of community facility, the development and operation of the community program and the community space and facilities are constantly considered in the follow-up studies. 3) The more residents have high community consciousness, the more they use the community facilities.

  • PDF

기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석 (An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units)

  • 유복희
    • 한국주거학회논문집
    • /
    • 제21권6호
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

장수명 주택의 활성화를 위한 가동칸막이벽체 개발현황 연구 (A Study on the Development and Application of Movable Partition Components for Facilitating of Long-life Housing)

  • 이성옥;김수암
    • 한국주거학회논문집
    • /
    • 제21권6호
    • /
    • pp.91-98
    • /
    • 2010
  • The purpose of this study is to develop the feasibility of movable partition wall components that are able to correspond changes of structure system and spatial configuration by the needs of residents for the activation of long-life housing. The key element of various movable partition wall components, a movable partition wall, was analyzed for problems through both as-is analysis and field installation in Korea and Japan, and then its feasibility was verified. The movable partition wall can break the uniformity of a fixed one, can integrate and separate limited space by changes in the demands of residents, can be easy to separate, and can be independent. The development of the movable partition wall is important for the realization of diverse residential space, ease of remodeling, environment adaptation, promotion of modularization, etc. It is comprised of surfacing materials, core materials, structural materials, and movable parts. The domestic movable partition wall was verified regarding the feasibility of an apartment house through on-site inspections and sound insulation tests by KOHP21, KICT. In conclusion, the construction of long-life housing that has sustainable values in the use of housing is nationally an important assignment, so as to secure good housing stock.

웹 기반의 공간정보예측시스템을 이용한 통합적 하수도 관리 시스템의 개발 및 적용 (An Integrated Sewer Management System using Web Based Predictive Spatial Information System)

  • 김준현;한영한
    • 환경영향평가
    • /
    • 제10권1호
    • /
    • pp.73-83
    • /
    • 2001
  • Web based integrated sewer management system was developed for the analysis of sewer flow and for the optimal operation of sewer works using ArcView and SWMM. SWMM and ArcView were dynamically linked together using Avenue in order to construct user-friendly information management system. The developed system was applied to the residential area in Choonchun city to verify its utilities. All the relevant field data were analyzed on the basis of the developed system, and the modeling of sewer flow was implemented using RUNOFF, EXTRAN, TRANSPORT in SWMM. This system is now in the process of connection to the management system of stormwater, surface and subsurface environment in order to develop an integrated environmental management system. Futhermore, this system will be a critical part of overall control system of sewer works including sewer network and wastewater treatment plant. As this system can provide comprehensive prediction of flow and pollution profiles, it could serve as a tool not only for the optimal management, but also for the decision support system to examine the efficiency of planning and implementation of sewer projects.

  • PDF

리모델링 공동주택단지의 외부공간 성능평가 비교 연구 (The Comparative Study on Performance Evaluation of Outdoor Space for Remodeling Apartment)

  • 김호윤;이상석;유주은
    • 한국환경복원기술학회지
    • /
    • 제19권4호
    • /
    • pp.1-17
    • /
    • 2016
  • In this study, remodeling projects are perceived as a sustainable urban management policy to boost the value of old apartments and stimulate urban regeneration and development. To evaluate the physical environmental performance of external spaces of remodeled apartments, an evaluation model was developed. After applying it to the target places, the following results were obtained. First, analysis of the external space change index of the target apartments revealed that institutional standards are necessary in line with the building arrangement type, parking lot expansion method, and changes in the building-to-land ratio. Second, the score ratio as to the external space change index performance is as follows: safety (48.30); pleasantness (25.90); convenience (18.90); eco-friendliness (14.90). In other words, "safety" had the biggest score ratio. Third, to boost the external space performance of remodeled apartments, the needs of residents and neighboring environmental plans should be considered from a communality standpoint.