• Title/Summary/Keyword: Residential building

Search Result 1,190, Processing Time 0.034 seconds

The Management Method for Preventing Frequent Defect about Each Inspection Part from The Data Analysis of Pre-qualification of Residential Building Reconstruction (주택 재건축 예비평가 자료분석을 통한 분야별 주요결함 발생현황 및 유지관리방안 고찰)

  • Bae, Cheol-Hak;Lee, Sung-Ok;Ji, Myoung-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2010
  • The purpose of this study is to classify defects of the residential building by analyzing the defect specified by prequalification of residential building reconstruction and to suggest the solution of the problem which can be arisen during each stage of plan, construction and maintenance. By sorting the main defects which is specified by pre-qualification of residential building reconstruction for three years from August 2006 to August 2009 into 4 catagories and analyzing the cause of the defects, we draw the way of maintenance to prevent the defects and make pleasant residential environment. The reason for the frequent defects from residential building is mainly deterioration. It occured on the finishing more than on the structure, which means that residents can find defects easier on the finishing than the structure and clear the demand for repair. The result of analyzing of pre-qualification of residential building reconstruction is that the defects mostly caused small, masonry constructed and lower apartment. The apartment which is not into legal right for maintenance naturally have more defects than the others. In conclusion, it is necessary to establish a law of obligation duty of the maintenance of small apartment.

A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building (초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구)

  • Park, Sang-Hoon;Cho, Ga-Young;Lee, Sun-Woo;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

A Study on the Design Process for Building in District of Housing through Preferences of Design Concept Determinants (개념도출인자의 선호를 고려한 주거지역 건축물의 설계과정)

  • Ryu Im-Woo;Jeong Ji-Seok;Choi Moo-Hyuk
    • Journal of the Korean housing association
    • /
    • v.15 no.6
    • /
    • pp.67-76
    • /
    • 2004
  • It is the purpose of this study that propose design process of building in residential district con-sidering preferences of design concept determinants. The procedure of this study is as follows : First, classifying concept determinants and then investigate the preference of concept determinants according to the use of building in residential district. It will be proposed the process of design concept determinants through such preferences. And We will investigate applicable steps for constructing an elementary school in land development district, in order to verify these process of architectural design. It was investigated paper-survey and case studies, made up questionnaires twice. In the results, we could verify that design process considering the preference of concept determinants in residential district. These results can help designers to design appropriately, according to building usage in residential district.

A Study on the evaluation of the Residential Environment Efficiency by Arrangement of Multi-Family Residential Buildings - focused on the evaluation of daylight and view environment - (공동주택 주동 배치유형에 따른 주거환경성능 평가에 관한 연구 - 일조 및 조망환경성능 평가를 중심으로 -)

  • Choi, Doo Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2009
  • To make a prediction for a change of residential environment caused by the building code in Seoul which includes loosening the distance between multi-residential buildings, proposals of the four main building arrangements by analyzing examples were selected and then, amount of daylight and view efficiency were analyzed and presented through computer simulation for the proposals. In the result of the analysis, there was a difference among the arrangements but, when the distance between buildings was applied 0.8H as the least, residential environment like daylight and view efficiency per unit significantly decreased in quality. Particularly, for the middle stories(6-15) and the high stories(16~24), when the distance between buildings decreased from the current measurement, 1.0H, to 0.8H, the analysis indicated that 28% of daylight and 7% of view efficiency were reduced. In the building arrangements, an order of the best residential environment was followed in this sequence; balanced arrangement of flat type as the best, combined arrangement between L-shape and tower types, balanced arrangement of tower type, combined arrangement between flat and Y-shape types, grid arrangement of flat type, and combined arrangement between Y-shape and tower types as the least.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

A Study on Characteristic of Super-Tall Mixed-Use Residential Building in the Outdoor Transition Zone (초고층 주거복합건물의 기단부 계획특성 분석에 관한 연구)

  • Kim, Kyoung min;Je, Hae seong
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.75-80
    • /
    • 2007
  • The purpose of this study is to analyze architectural plans of lower part of super tall mixed-use residential building for understanding its functions for urban. The area of this research are limited to super tall mixed-use residential building which were built in Seoul, Kyoung-gi area, and new towns. For this purpose, theories for super tall mixed-use residential building and non-housing parts were researched, and characteristics of selected cases for field research were analyzed by studying drawing materials. The research focused on scale, type of building, included programs for public spaces, and characteristics of location. As a result, every cases were designed as 'outdoor transition zone-centered type', and for urban function, non-housing facilities were condensed to increase convenience. In addition, ratio of non-housing part were incresesed with public spaces design for residents, and various programs were inserted.

A Study on the Improvement of Human Safety Standards Considering Fire Cases in High-rise Residential Facilities (고층 주거시설 화재사례를 고려한 인명안전기준 개선방안에 관한 연구)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.106-107
    • /
    • 2021
  • The fire in Ulsan in 2020 was a 33-story residential and commercial complex with about 90 injuries and more than 10 billion won in property damage, and considering the recent increase in high-rise residential and commercial complexes, the risk of similar fires is high. As can be seen through the residential and commercial complex fire case in Ulsan, life-based fire safety standards need to be established to minimize casualties. Therefore, the purpose of this study is to draw improvements for the development of human safety standards for high-rise residential facilities in the future through comparison with the Korean Building Act, Firefighting-rellated Acts and the U.S. NFPA 101.

  • PDF

A Study on the Correlation of Residential Satisfaction of Dwellers and the Size of Housing Unit in Apartment Housing (공동주택규모와 옥내외 물리적 주거환경만족도의 상관관계 연구)

  • Kim, Gi Soo;Shin, Jin-Hwan
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.101-108
    • /
    • 2013
  • The purpose of this research was to analyze the correlation of residential satisfaction and the size of housing unit in apartment housing through the case study of 1,619 samples of 36 housing estates. The contents of this research consisted of two main parts. The first part was to identify the differences of residential satisfaction of dwellers, based on the size of housing unit, in apartment housing. The second part was to analyze the characteristics of residential environment, which might have an influence on the differences of residential satisfaction. the findings of this study were that the residential satisfaction of dwellers was proportional to the size of housing unit except $39m^2$ under housing unit, and the size of housing unit was not proportional to the residential satisfaction of outdoor openness exactly, but the size of housing unit was proportional to increase of the distance between building and building, and decrease of the building surface coverage ratio to outdoor area. This research will contribute to the establishment of the site planning methods which increase residential satisfaction in apartment housing, while promoting the quality of residential environment in Korea.

Interlocking Earthen Masonry Units for Sustainable Residential Building Construction

  • Lubbering, Noah;Awolusi, Ibukun;Langar, Sandeep;Schultz, Arturo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1024-1031
    • /
    • 2022
  • In addressing the goal for sustainability in the construction industry, the very materials used for construction and the methods utilized to implement said materials must be analyzed. Specifically, some traditional residential construction materials consist of wood, steel, and concrete. Because these materials vary in their levels of sustainability, there is a need to develop and explore new or other materials that can be used for residential construction. The primary purpose of this paper is to provide a review of interlocking earthen masonry units (IEMU) as an alternative option for residential building construction. This is in an effort to explore the variables impacting their existing and potential applications as sustainable materials and a method for residential building construction. IEMU's are then examined under the triple bottom line (TBL) sustainability framework which includes analyzing the environmental, economic, and social sustainability of IEMU's. The findings of this review may lead to further progression in the development of a framework for evaluating U.S. stakeholder adoption of IEMU's and potential implementation in U.S. residential construction.

  • PDF

A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA - (공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 -)

  • Yoon, Sung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.4
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.