Efficient Vibration Analysis of Floors in A Shear Wall Building Structure (벽식구조물 바닥의 효율적인 진동해석)

  • 김현수;이동근;이선화
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.357-364
    • /
    • 2004
  • Recently, many high-rise apartment buildings using the box system composed of only reinforced connote walls and slabs, have been constructed In residential buildings such as apartments, vibrations occur from various sources and these vibrations transfer to neighboring residential units through walls and slabs. It is necessary to use a refined finite element model for an accurate vibration analysis of shear wall building structures. But it would take significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Therefore an efficient analytical method, which has only translational DOFs perpendicular to walls or slabs by the matrix condensation technique, is proposed in this study to obtain accurate results in significantly reduced computational time.

  • PDF

Evaluation on the Characteristics of Noise Reduction according to the Tunnel Section Shape (방음터널 단면형상에 따른 소음저감 특성 평가 - 터널 내부소음을 중심으로 -)

  • 이원열;김하근;오양기;주문기;조성환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1014-1019
    • /
    • 2003
  • It seems inevitable for residential buildings to be high-rise and allocated near traffic roads due to the overcrowding in urban area. Acoustic environment in those area has been seriously deteriorated by the increase of traffic vehicles. Commonly used sound barriers have a limitation in controlling noise due to diffraction noise of sound barrier. Hence sound barrier is not effective to attenuate noise especially for the residential units in high level. This work aims at evaluating noise reduction according to the tunnel section shape by using 1/5 scale model. We carried out a number of field measurements for 1/5 scale model of Noise Barrier Tunnel with various sectional shape. The results from predictions and the measurement show generally good agreement.

  • PDF

A Field Survey on Number and Volume of the Living Commodities of Children (초등학생의 생활재 수량 및 용적특성에 관한 현장조사연구)

  • 이연숙;조은경;김주연;권오진;허진민
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.143-148
    • /
    • 2002
  • Residential indoor space is a major living setting for young children where multi-dimension at development can be expected through the interaction with items and components of the environment. The physical environment and attributes have been, however, relatively ignored. Especially during last several decades of housing development, residential units have been produced without accurate understanding of residents' material possession. To better design living environments, especially, a life setting for children, this research focused on finding out the characteristics of living items which belong to and are used by children.

  • PDF

A Study on the Circular Multi-Family Housing for Designing Local Identity (지역성 구현을 위한 집합주택 원형 주거동의 표현 특성 연구)

  • Moon, Eun-Mi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.121-129
    • /
    • 2013
  • This study was aimed at determining the characteristics of circular multi-family housing under the assumption that the shape of a residential building affects local identity. A total of six case studies were included in this study, three case studies on idle historical industrial facilities turned into residential buildings and another three on multi-family housing located in newly developed residential complexes. The study drew its conclusions as follows. First, the design of circular multi-family housing was intended to maximize security and defense from the outside in older times. This was later developed as the terrace house style with geometric urban squares designed under the urban planning of the Baroque period. This evolved high-density housing with a courtyard in the center offering a green open space, with the aim of restoring a sense of humanity. Second, the six case studies on circular multi-family housing were analyzed from the viewpoint of each factor of local identity, including historical and cultural, landscape, and community. Third, the historical and cultural elements of circular multi-family housing are found in some unused historical industrial facilities remodeled into residential buildings. They provide new capabilities and shapes desired by society at a given time, while maintaining familiar styles and elements of history, integrating a legacy of the past into the present. Fourth, circular multi-family housing with unique shapes and structures often become landmarks of a region with their distinctive appearance against a uniform urban environment and the monotonous scenery of residential complexes. They also show a high level of visual awareness with the distinctive shapes made possible when new elements are added to a historical exterior. Finally, circular multi-family housing with courtyards in the center prompt social contact between inhabitants, especially with dormitories and rental houses for the low-income bracket, which provide a small individual units with high use common space. Circular multi-family housing are planned in a manner similar to a small village or a city. They are designed to enhance sense of community, allocating various public amenities and provide cultural and commercial spaces on the ground floor and courtyard areas.

Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation (5kW 급 주택용 고분자 연료전지 시스템)

  • Yang, Tae-Hyun;Park, Gu-Gon;Yoon, Young-Gi;Lee, Won-Yong;Yoon, Wang-Lai;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

Comparisons of Young Renter Households' Housing Situation by Locations Reflected in the 2012 Korea Housing Survey (2012년 주거실태조사에 나타난 청년 임차가구의 지역별 주거 실태 비교)

  • Lee, Hyun-Jeong
    • Journal of the Korean housing association
    • /
    • v.26 no.1
    • /
    • pp.81-90
    • /
    • 2015
  • The purpose of this study was to investigate housing characteristics of young renter households by locations using licensed microdata of the 2012 Korea Housing Survey. There were 1,020,216 renter households (weighted count) headed by persons between 20 and 34 years of age, and their housing characteristics were compared statistically across their residential locations (Capital Region, metropolitan cities, other areas). Major findings are as follows: (1) Capital Region young renters had the worst housing quality to have the greatest proportion of households living in units failed to meet national minimum housing standards, and/or in basement or semi-basement units; (2) Capital Region young renters had the greatest proportion of households that had housing cost burdens; and (3) 37.3% of young renter households in metropolitan areas and 33.5% in Capital Region were found to receive family support in order to afford current rental costs.

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Experimental Study on the Effect of Environmentally Friendly Materials on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 친환경 마감자재 사용에 따른 실내공기질 개선효과 실증연구)

  • Park, Young-Sok;Lee, Gyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.139-142
    • /
    • 2006
  • The indoor air quality of new apartment buildings, which is known to cause sick housing syndrome, has become a major concern among apartment residents as well as construction companies in Korea. In this study, the effects of environmentally friendly materials and ventilation system are evaluated to compare the strategies applied to improve indoor air quality at the pre-occupancy stage. Six residential units are tested under three conditions : one unit is consisted of environmentally friendly materials and ventilation system, another unit is consisted of environmentally friendly materials and non-ventilation system, and the other four units are consisted of common materials and non-ventilation system.

  • PDF

A Study on Ecological Characteristics of Interior Design for Apartment Building - A Case Analysis of Model Houses for Medium- and large-sized Pyeong Apartments in Busan Area - (아파트 실내디자인의 생태적 특성에 관한 연구 - 부산지역 중.대형 평수 아파트 모델하우스 사례분석 -)

  • Shin, Jae-Moon;Youn, Ji-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.181-191
    • /
    • 2007
  • This study attempted to analyze the characteristics of interior design of the apartment units of Model-houses in terms of ecological aspects. 9 companies that possessed their model houses among the construction companies in Busan area as of August 2006 were selected. 20 units in the model houses of these companies were visited and analyzed. Through literature review, the guideline for the environmentally-friendly residential design was designed and developed to the checklists. The data collected were analyzed to find out the ecological characteristics of the interior space of apartment units. The findings are the followings. First, energy efficiency was properly considered in terms of natural lighting and natural ventilation. Second, in sustainability, the materials for floors and walls could not be reused even though they were environmentally-friendly. Water system needs more improvement for sustainable development including grey-water and rain recycling system. Third, interior greening should be applied more for better environment both physically and emotionally. It is expected that future housing will be more high-risen and densely-populated apartment spaces. Therefore, an approach to new ecological aspects including an emphasis on interior greening, use of eco-materials and adhesives, water recycling and flexibility of the spatial configuration should be made for the next generation.

Energy Load according to the Units of Apartment House (공동주택 세대 위치에 따른 에너지 부하량)

  • Kim, Sung-Hoon;Lee, Jun-Gi;Kim, Yong-Tae;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.78-83
    • /
    • 2015
  • In Korea, multi-housing in one of the most common types of residential space due to its easy management and convenience. In particular, south-facing plate-type(一) multi-housing has attracted a great deal of public interest because it consumes less energy compared with other types of multi-housing, making it advantageous from an energy-saving perspective. Although there have been many studies on the annual energy consumption of multi-housing in relation to building shape and area of window, there have not been sufficient research on the annual energy consumption of multi-housing in relation to individual units of the multi-housing. The purpose of this study is to propose a strategy for reducing energy consumption in plate-type(一) multi-housing, taking the units with the lowest energy consumption as the standard. The result, Standard Models's energy load was as 4000 ~ 5600kWh, and Passive Houses's energy load was less than Stand Models at the 1600kWh.