• Title/Summary/Keyword: Residential Unit

Search Result 343, Processing Time 0.025 seconds

Carcinogenic risk assessment of heavy metals in suspended particulates of Seoul (서울시 대기 부유 분진중 중금속에 대한 발암 위해성 평가)

  • Shin, Dong-Chun;Chung, Yong;Kim, Jong-Man;Lim, Young-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 1994
  • This study was conducted to assess the health risk of carcinogenic heavy metals such as arsenic, nickel, chromium and cadmium Ambient concentrations of these metals were measured bimonthly, during May 1987 to March 1988. Respirable Particle concentrations of As, Ni, Cr, Cd in traffic area(Shinchon) were 16ng/㎥, 43ng/㎥, 4.2ng/㎥, 6.6ng/㎥, respectively, and in residential area(Bulkwang) were 25ng/㎥, 32ng/㎥, 4.7ng/㎥, 8.9ng/㎥, respectively. Carcinogenic risk of each metal was calculated by multiplication of ambient concentration and unit risk of the metal which was referred to recent version of Integrated Risk Information System(IRIS). Sum of the risk from these for metals was 9.8$\times$10$^{-5}$ as individual risk in traffic area and 13.9$\times$10$^{-5}$ in residential area.

  • PDF

A study on the social housing policy and architectural culture in Italy - Focused on the case of INA (Istituto Nazionale delle Assicurazioni) - Casa 1949-1963 - (제2차 세계대전 이후 이탈리아 주거정책과 건축문화의 역사적 고찰 - 이탈리아 국립보험공단 주택국의 주거정책을 중심으로 1949-1963 -)

  • Kim, Il-Hyun
    • Journal of the Korean housing association
    • /
    • v.19 no.6
    • /
    • pp.137-144
    • /
    • 2008
  • Public housing problem became a major issue in each European country during the period of the reconstruction. This study focuses on the one of the major institutional policies in the public housing sectors in Europe during the second postwar period, specifically the INA (Istituto Nazionale delle Assicurazioni)-Casa in Italy from 1949 to 1963. Thanks to the financial Aid provided by 'Marshall Plan' of United States government, Italy initiated INA-Casa housing program elaborated and realized by minister of Labour, Amintore Fanfani. He was strongly influenced by catholic socialism and Weberian corporatism, and also had previously written theoretical studies on the subject during the Interwar years. The outcome of this policy had been devaluated for its Keynesian aspect as well as vernacular predominance in the architectural forms. On the contrary, this study focuses on themes such as continuity of politics before and after the Liberation, status of the architects and their will to social engagement, notion of quarter as 'self-sufficient community' and 'residential unit'. These factors will allow to comprehend the complex nature of the reality where different categories were involved to resolve the common housing problem.

A Study on the Planning Alternatives for the Residential Environment Improvement of the New Rural Village(the YoungMoon Project Site) (농촌문화마을 주거환경개선을 위한 공간계획 방향 연구 - 경기도 양평군 광탄리 용문지구 문화마을계획을 중심으로 -)

  • 임승빈;조순재
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.1
    • /
    • pp.22-31
    • /
    • 1998
  • For the improvement of the cultural rural village(new rural village project), it is very important to find the various planning alternatives. The purpose of this study is to suggest the ideas which are able to be applied to the rural site planning. The YoungMoon project site located in Kyunggi province was selected case study, The followings are suggestions developed in the process of preparing an alternative plan for the case study. 1) The preparing of the rural site plan is the organizing process of the planning ideas responsive to the condition of both a project site and the project directions. 2) In developing the schematic plan, it is very useful to introduce the cluster madang (small public open space) including 25 houses as a basic planning unit. 3) In comparison with the project plan, the alternative plan presented by this study has advantages of amenity and public space of the residential environment of the new rural village. It is properly said that we have to more and more discuss the best solution to take in planning the rural site, and this efforts contribute the improvement of the quality of the new village project.

  • PDF

A Study on the Development of Precast Concrete Modular and its Application Onsite (프리캐스트 콘크리트 모듈러 개발 및 현장적용에 관한 연구)

  • Bae, Kyu-Woong;Boo, Yoon-Seob;Shin, Sang-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.27-28
    • /
    • 2023
  • Currently, the Off-Site Construction (OSC) construction method, which emphasizes the minimization of field work, is being emphasized at construction sites due to the lack of construction skilled manpower, extreme weather, and the Severe Disaster Punishment Act. In this study, we developed a stacked PC modular, which is a method of stacking PC modules, and solved the lifting problem by reducing the weight of the unit module, which is emerging as the biggest disadvantage of PC modules, to around 20 tons. For the connection between modules, structural safety was secured through repeated history tests of the wall and slab connection. Walls and slabs satisfied all statutory fire resistance times through fire resistance tests, and residential performance was evaluated to be satisfactory through mock-up demonstration. The developed PC modular has been applied to the construction of commercial houses, detached houses, shopping malls, churches, etc., and has design results for many buildings such as dormitories, detached houses with 4 floors or more, and resorts, so it is expected that an atmosphere of revitalization of construction methods will be created.

  • PDF

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

GHG-AP Integrated Emission Inventories and Per Unit Emission in Biomass Burning Sector of Seoul (서울시 생물성 연소부문 온실가스-대기오염 통합 인벤토리 및 배출원단위분석)

  • Jung, Jaehyung;Kwon, O-Yul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.83-91
    • /
    • 2015
  • Biomass burning is known to be one of the main sectors emitting greenhouse gases as well as air pollutants. Unfortunately, the inventory of biomass burning sector has not been established well. We estimated greenhouse gas (GHG) and air pollution (AP) integrated emissions from biomass burning sector in Seoul during year 2010. The data of GHG and AP emissions from biomass burning, classified into open burning, residential fireplace and wood stove, meat cooking, fires, and cremation, were obtained from Statistics Korea and Seoul City. Estimation methodologies and emission factors were gathered from reports and published literatures. Estimated GHG and AP integrated emissions during year 2010 were $3,867tonCO_{2eq}$, and 2,320 tonAP, respectively. Major sources of GHG were forest fires ($1,533tonCO_{2eq}$) and waste open burning ($1,466tonCO_{2eq}$), while those of AP were meat cooking (1,240 tonAP) and fire incidence (907 tonAP). Total emissions by administrative district in Seoul, representing similar patterns in both GHG and AP, indicated that Seocho-gu and Gangseo-gu were the largest emitters whereas Jung-gu was the smallest emitter, ranged in $2{\sim}165tonCO_{2eq}$ and 0.1~8.31 tonAP. GHG emissions per $km^2$ showed different results from total emissions in that Gwanak-gu, Jungnang-gu, Gangdong-gu and Seodaemun-gu were the largest emitters, while Seocho-gu and Gangseo-gu were near-averaged emission districts, ranged in $0.2{\sim}21tonCO_{2eq}/km^2$. However, AP emissions per $km^2$ revealed relatively minor differences among districts, ranged in $2.3{\sim}6.1tonAP/km^2$.

A Study on the Housing Type and Space Extension of the Traditional Houses in Samcheok Region (삼척지역 농촌재래주택의 주거유형과 공간확장에 관한 연구)

  • Choi, Jang-Soon;Kim, Jin-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.2
    • /
    • pp.25-32
    • /
    • 2013
  • The purpose of this study is to analyze the residential space composition and extension of Jeonja-jip and Dureong-jip in Samcheok region. The results of this study are as follows. It appears three residential plan types - Jeonja-jip with Anmaru(a room made of wooden floor), Jeonja-jip without Anmaru and Dureong-jip with Anmaru- in survey region. It was needed the extension of residential space at Jeonja-jip(a house type with two-row rooms which be composed of 田type under one roof) and Dureong-jip(a house type with inner floor which be surrounded by rooms under one roof) because of shortage of sleeping space, working space and keeping space owing to growing large family. The solutions of these shortages will be the extension of space in houses. Jeonja-jip's basic type which is the Kyup-Jip(a house type with two-row rooms under one roof) of 一 type with 6 Kans(Kan, a unit to count room to divided with four posts) is transformed and extended to 田shaped house with 11 Kans toward X-axis orientation. Dureong-Jip's basic type which is ㄱ type with 7 Kans is transformed and extended to the Sekyup-Jip with 9 Kans and the Nekyup-Jip(a house type with four-row rooms under one roof) with 12 Kans toward Y-axis orientation by insertion and addition. Jeonja-jip was developed into Kyup-Jip with front 4 or 5 Kans and side 2 Kans instead of being done into Sekyup-jip or Nekyup-Jip with insufficient day lighting and ventilation problems. Jeonja-jip and Dureong-jip were stronger than any other traditional houses in tendency to reserve Magu(cowshed) and Chikkan(toilet) in a house.

Selection of Ventilation Rate and Filter for a Residential Housing in View of Indoor Particle Concentration (공동주택의 적정 환기량 및 필터의 선정 - 실내입자농도를 중심으로 -)

  • Noh, Kwang-Chul;Jung, Yee-Kyeong;Hwang, Jung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.517-522
    • /
    • 2008
  • Ventilation rate and filter were selected to simultaneously satisfy indoor air quality and minimize energy consumption in residential housing. The concentrations of indoor particles were calculated using an adapted mass balance model for various ventilation airflow rates. To satisfy the guidelines for indoor concentrations of particles, the minimum ventilation rates of 1.0/h, 0.6/h and 0.4/h were required for MERV11, MERV13 and MERV14, respectively. And the fan power consumptions induced by ducts, a heat exchanger and a filter were calculated for various ventilation airflow rates. The increase in the ventilation rate caused a dramatic increase in the power consumption, but the filter performance did not have much of an effect on the fan power for ventilation airflow rates lower than 0.4/h. The use of the ventilation filter of MERV 14 was suggested at a ventilation rate of 0.4/h when the fan power consumptions were considered in addition to the indoor concentrations of particles and $CO_2$. The use of the MERV14 filter at a ventilation rate of 0.6/h could be more effective than the additional use of an indoor air cleaner when the residential housing unit was ventilated.

  • PDF

PAZ-based Parking Supply and Operation Planning Model Considering Land Use (토지이용을 고려한 주차분석존(Parking Analysis Zone) 기반 주차 공급 및 운영 계획 모형)

  • Yu, Jeong Whon;Hur, Kyum;Ryu, In Gon;Jeon, Gyo Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.659-669
    • /
    • 2022
  • Recently, parking problems have repeatedly occurred not only in the residential areas of the old town, but in detached residential areas, neighborhood living facilities, and commercial areas of the planned New Town. This study suggests a strategy to minimize parking problems before constructing a New Town by reviewing these parking problems at the new city district planning stage. Parking problems can be divided into supply-demand and non-supply-based, and the solution strategy is reviewed in terms of supply and operation. The procedure for applying the solution strategy is proposed according to the effectiveness and ease of application.First, this paper suggests the PAZ (Parking Analysis Zone) as the basic analysis unit. Second, the supply-based parking problem in the concerned area based on the land use plan of Hanam Gyosan is reviewed. Last, solutions to a parking problem for each PAZ are presented.

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.