• Title/Summary/Keyword: Residential Architecture

Search Result 937, Processing Time 0.022 seconds

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

A Study on the Openness of Landscape in Urban Cross Intersections (도시 내 십자형 교차로 경관의 개방성에 관한 연구)

  • Shin, Yu-Kyoung;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.2
    • /
    • pp.65-78
    • /
    • 2015
  • An important factor in assessing the beneficial qualities of a city's intersection spaces can be measured by examining a pedestrian's approach to the space and calculating the openness observed in the overall design of adjacent buildings. These spaces are influential, since they offer opportunities for pedestrians to spend time and take in views of the surrounding environment. The intersection of horizontal components in cities such as Bundang-si and Suwon-si can provide a sense of openness or greenness. We believe that there is a need for careful analysis and study of such components, as defined by designations in Bucheon-si research, and that this study can give important insights for future urban planning and design. When assessing the openness of an intersection, a key variable is the reported rate of perforation, which factors into the greenness of a space. Because of the large and varied scope of this research, this rate is highly variable, as there were many differences between each site. In descending order of average ratios: Seongnam-si, 41.79% > Bucheon-si, 35.40% > Suwon-si, 30.42%. The data compared for each city was divided into study sites selected at downtown locations as well as in urban outskirts. Openness and greenness were analyzed at each downtown and outskirt site. A summary of the results shows a decreased openness average of -2.63% in downtown locations versus outskirt. The greenness ratios in urban outskirt areas were 4.86% greater than downtown locations on average. As it relates to the results of this analysis of openness, the comprehensive property zoning for each city was determined as a ratio of residential to commercial designations. This study analyzes view points within urban cross intersections in the downtown landscape. It presents basic data and research directions to promote a better environment with regard to openness, and consists of an analysis of the relationship between a variety of physical components.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

A Comparative Analysis on the Frequency and Importance of Home Renovation for the Disabled -Focused on Accessible Path and Internal Space - (장애인 주택개조 빈도 및 중요도 비교분석 -접근로 및 내부공간을 중심으로-)

  • Lee, Kyoo-Il;An, Sung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.27-36
    • /
    • 2016
  • Houses have usually been planned for those who are in good physical condition rather than with disabilities. Therefore, it is difficult to provide a high quality residential environment for people with disabilities. To live in their own houses continuously, it is essential to renovate their houses where they have been living. This study focuses on removing the barrier factors from houses by analyzing the characteristics of disability types and purpose of each space. Therefore, this study divides a house into 5 sectors: an accessible path; an entrance hall; a corridor; a living room; and a bedroom to remove the barrier factors from each sector according to the analysis above. As a result, the sectors that show high frequency and importance of renovation should be considered as a top priority for renovation.

Design and Implementation of the Interoperability method for the Remote OSGi services (원격 OSGi 서비스의 상호운용 기술 설계 및 구현)

  • Kim, Eun-Hoe;Yun, Ki-Hyun;Choi, Jae-Young
    • Journal of Internet Computing and Services
    • /
    • v.12 no.1
    • /
    • pp.11-25
    • /
    • 2011
  • In ubiquitous computing environment, OSGi has applied to many areas such as digital mobile phones, vehicles, telematics, embedded appliances, residential gateways, industrial computers, desktop PCs, and high-end servers including mainframes. Therefore, interoperability is required for remote OSGi services which are built on various devices. In this paper, we proposed a method which was able to interoperate remote OSGi services using RMI paradigm. RMI is a representative middleware technology in distributed computing environment. The suggested method is based on the standard OSGi technology. It is possible to provide remote OSGi service registration, finding, and binding methods which were suitable for the OSGi service-oriented architecture. We also provided reliability of the dynamic remote OSGi services by maintaining consistent properties of them, and we could provide location transparency of the remote OSGi services by generating proxy bundles and proxy services dynamically.

A study on the Architectural Characteristics of Kyungduk-Dan and Manun-Jae in Miryang -Mainly about the Characterics of Traditional Houses in modern era(1876-1945)- (밀양(密陽) 경덕단(景德壇)과 만운재(萬雲齋)의 건축적 특성 - 근대한옥의 성격을 중심으로 -)

  • Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.10 no.1 s.25
    • /
    • pp.9-23
    • /
    • 2001
  • This study is for the Kyungduk-Dan(as a altar of Milsung-Daegun) and The Manun-Jae the characteristics(lay out and planning, window patterns, structure, materials) of the the Korean traditional house during the modern era. Before Manun-Jae was used for the house. The Kyungduck-Dan was constructed in August according to the Lunar Calender in 1927. The Manun-Jae(house for Ki-hun Kang, millionaire ) was completed in 1924. Modern Architectures brought to Korea with the bricks, the tiles, the flash doors, the plate grasses, the brass hardwares. These architectural material was used in positive. During the construction of Manun-Jae in 1924, it happened the architectural exchage among a korean, a chinese and a japanese constructor. Though using the air exhaust valve at the kitchen of Ukyung-Kak( old Anchae), it could be assume that the modern convenience and the improvement of residential environments was considered at that period during the construction of Manun-Jae. That construction was elected with the brick($222mm{\times}106mm{\times}50mm$), the chinese colored tile and plate glass such a modem materials. The new shape of the korean lattice window and the wooden flash-door with glass was used. In Ukyung-Kak, the Chan-Maru(service space) and the kitchen such as a service space or concise utility zone was organically connected. Especially, considered the domesitic activity and circulation, the western kitchen sink and the Chan-Maru(service space) was rationally placed. At the Manun-Jae and the Kyungduck-Dan, the architectural characteristic is that the new shape of windows was used. The lattice window at the Ondol room of Ukyung-Kak, was rgadually added the plate glass and the wood plate. The lattice window with the grid shape at kitchen of that building was adapted japanese grid lattice window in korea at that period. It is the sample that korean traditional house was typically influenced from the japanese resident culture. The Manun-Jae and the Kyungduck-Dan as the modern house kept the form of korean traditional architecture, and was partially adapted a modern characteristic space and modern architectural materials. During the japanese occupancy, these residence can be showed the transition in formally.

  • PDF

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations (오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획)

  • Kim, Jiyoeng;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.