• 제목/요약/키워드: Resident's responses

검색결과 31건 처리시간 0.023초

공동주택의 겨울철 실내공기환경에 대한 거주자 반응 (Resident's Subjective Responses to Indoor Air quality of Multi Family Houses in Winter)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제35권2호
    • /
    • pp.173-186
    • /
    • 1997
  • The purpose of this study is to find out understand the resident's subjective responses to physical indoor environment. The questionnaire survey was carried out to measure form Jan. 8th to Feb. 2th in 1996, the typical external climate of winter in Korea. The subjects were four hundred and eleven housewives, living in apartments of RC structure I Ilsan apartment complex. As the result, residents usual ventilate once or twice a day by opening outward windows for about ten minutes. Unpleasant smell producted by cooking and wet garbage made most of them negatively respond to kitchen's air quality. regression analysis of relativeness between sense of air freshness smell, dust and comfort revealed that sense of comfort was the most highly related with the extent of bad smell. Housing factors such as size of apartments and ventilating, smoking and gas usage had significant effects on indoor air quality and the subjective responses in winter. Therefore it is especially important to consider air pollution problem from the beginning stage when planning small apartments. It is required that the government of environment has to emphasize the importance of ventilation to residents, and makes an effort to establish the design criteria on indoor air quality in house.

  • PDF

바닥 복사 난방시 바닥온도와 거주자 자세 변화에 따른 인체 반응에 관한 연구 (The Study of Human Response for Floor Surface Temperature and Resident's Posture Change)

  • 김동규;김세환
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.846-851
    • /
    • 2012
  • The radiant floor heating system is traditional heating system in korea. Radiant floor heating is small in vertical temperature difference, air stream and radiant heat distribution is uniform. And radiant floor heating system provide thermal comfort conditions to the a resident. This study was undertaken to evaluate the physiological-subjective responses of the resident's posture change such as sitting and standing. The experimental investigations were carried out in climate chamber, and subjects were 4 college-age students in good health. The physiological response was skin temperature and subjective response was undertaken survey of TSV and CSV. The results were summarized as follows; The comfortable temperature range of plantar surface was $35.1{\sim}38.9^{\circ}C$ and buttock surface was $37.8{\sim}39.3^{\circ}C$.

전통온돌방의 실내온열환경 및 온열감에 관한 연구 (Evaluation of Indoor Thermal Environment and Thermal Sensation in Traditional Ondol Room)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 2004
  • The aim of the research was to evaluate the characteristics of indoor thermal environment and thermal sensation in the traditional Ondol room. Indoor thermal factors including air temperature, operative temperature, floor surface temperature, relative humidity, PMV, OT were measured, and survey was carried out to understand subjective responses of resident's related to indoor thermal environment in Ondol room. The analysed houses are: the Chung hyo dang(the head house of Ryu family in Andong) and the Pyeung won jung(the traditional house in Yesan). The purpose of the survey was to know the relationship between resident's sensation and thermal environmental indicators such as air temperature, relative humidity, floor surface temperature, OT. The experimental results have pointed out how Ondol room may lead to comfortable and uniform indoor thermal environments.

남한산성도립공원 등산객과 비등산객의 장소 가치인식 비교 연구 (Comparison between Hiker and Non-hiker's Sense of place value at Namhansanseong Provincial Park)

  • 김예은;김현;백난영
    • 농촌계획
    • /
    • 제21권4호
    • /
    • pp.127-137
    • /
    • 2015
  • This Study attempted to comprehend difference between hiker and non-hiker's sense of place value at Namhansanseong Provincial Park. Especially, it was analyzed after visitors, who were divided into local residents & tourists and first time visitors & repeat visitors. Out of 600 visitors, who were over 19 years old, participated in the survey, 587 responses were used for data analysis. Consequently, Sense of place value at Namhansanseong Provincial Park were classified into three factors: Health Culture, Ecology Environment, and Connectedness. Hikers feel higher value on promotion of health, relaxation, environment than non-hikers. Among hikers, local residents feel higher value on ecology environment and connectedness than tourists. Among non-hikers, however, they have no difference between local residents and tourists, only repeat visitors and first time visitors. On this result, possibility of resident participation management on natural environment and trail was considered, and when the program, which is for raising cultural and traditional value, would develop, increasing number of repeat visitor should be considered as a high priority.

신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응 (TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments)

  • 최윤정;안혜정;강미라;이혜민
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;오예슬;장윤정;김정재
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

주거침입 피해에 영향을 미치는 요인 (A Factor having Influence on Housebreaking Victimization)

  • 이유나;정대관
    • 시큐리티연구
    • /
    • 제38호
    • /
    • pp.137-161
    • /
    • 2014
  • 이 연구의 목적은 주거침입피해에 영향을 미치는 요인을 탐색하는데 있다. 이에 주거침입 피해 실태를 구체적으로 살펴보고 인구사회학적 특성 및 일상적 생활양식과 주거침입 피해경험 간의 관계 및 영향력을 살펴본다. 또한 일상활동 생활양식이론에 기초하여 근접성과 노출, 보호능력 요인으로 주거침입 피해를 설명한다. 연구대상은 전국의 4,710가구로, 제8차 전국범죄피해조사(KCVS)자료를 이차데이터로서 활용하였고, 연구목적 달성을 위해 위계적 로지스틱 회귀분석방법을 이용하였다. 연구결과 근접성 및 보호능력 차원에서 피해를 설명할 수 있었으며 이는 범죄와의 근접성이 높을수록, 물리적 보호능력 수준이 높을수록 주거침입 피해 가능성은 감소한다고 볼 수 있었다. 하지만 이차데이터의 특성상 측정변수를 근사변인으로 설명함으로써 이론적 모형을 명확하게 반영하지 못했다는 한계를 갖는다. 향후 연구에서는 주거침입 피해유발요인 명확하게 측정하여 보다 실질적인 침입피해 예방정책이 마련되기를 기대한다.

  • PDF

아파트 내부공간에 대한 거주자 의식 및 평가 (Resident's consiousness and evaluation toward apartment interior space)

  • 지순;이연숙;유성희;오찬옥;최병숙;홍선경
    • 대한가정학회지
    • /
    • 제24권1호
    • /
    • pp.75-93
    • /
    • 1986
  • This research is to understand the residents' responses and evaluation about their apartment interior environment and thereby to be used as the basix data for designing residential space environment of new apartment complex in Sanggae area. The specific obectives of research were 1) to examine the residents' vale and life style concerning several specific rooms, 2) to find out residents' evaluation on physical characteristics, and 3) to understand residents' preference and demand for characteristics of interior space. Research method used was personal interview using a structured questionnaire. Residents living in 13, 15, 18, 22, 25 pyung in three selected large apartment complex areas provided dada : 777 questionnalires were used for analysis. Data were analyzed using the SPSS computer package. The statistics used were frequency, percentage, mean, F-test, χ\sup 2\-test, Duncan's multiple range test, Pearson's correlation coefficient.

  • PDF

INCENTIVE/DISINCENTIVE PROJECT SUCCESS FACTORS DURING MACARTHUR MAZE I-580 BRIDGE SPAN REPLACEMENT

  • Jae-Ho Pyeon;Marc Zomoradi
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.328-331
    • /
    • 2013
  • Incentive/Disincentive (I/D) contracting experiences in many states have been evaluated in terms of time and cost performance and substantial project time savings were found in many project cases. However, there is little understanding on individual project success factors for I/D projects during construction. This paper explores the significance of I/D clause in the success of the MacArthur Maze reconstruction project and summarizes a list of group causes that explains and elaborates on the detailed factors. The methods used for carrying out this study started with a search of online media and news reports and contract documents were also obtained from Caltrans. After review of the preliminary information, Interviews were performed with the Caltrans Resident Engineer and the contractor's project manager who were in charge of the MacArthur Maze reconstruction. In conclusion, the evaluation of their responses hinted at six significant cause groups responsible for the project's success. These groups can be listed as: 1) Motivation, 2) Policy, 3) Teamwork, 4) Communication, 5) Expectation, and 6) Resource Management.

  • PDF

농촌지역 독거노인주택의 겨울철 실내환경 실태 (The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter)

  • 최윤정;김윤희;김란희
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.452-457
    • /
    • 2008
  • The purposes of this study were to determine the actual state of indoor environment and to analyze the relationship between the living factors and indoor physical elements in solitary elderly houses at rural district during winter. The field surveys were consisted of measurements of physical elements, observations of living factors, and interviews of resident's responses. The field surveys were fulfilled in 4 houses from February to March 2008. Measuring elements were air temperature, relative humidity, floor temperature, seated place temperature, $CO_2$, CO, and illumination. The results showed that the average of indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was $30.6{\sim}55.4%$, floor temperature was $13.9{\sim}24.0^{\circ}C$, seated place temperature was $27.6{\sim}51.1^{\circ}C$, $CO_2$ was $1434.6{\sim}3305.5ppm$, CO was $2.8{\sim}8.4ppm$, illumination was $31.0{\sim}96.7lux$. The residents' clothing values were $1.10{\sim}1.78clo$. Most of the residents' subjective responses were in discord with the physical elements. It was evaluated to be uncomfortable state, and the main reason was revealed lack of heating and ventilation.

  • PDF