• 제목/요약/키워드: Reservoir Tank

검색결과 88건 처리시간 0.025초

보령담수호 유역의 유출 오염부하량 추정 (Estimation of Runoff Pollutant Loadings in Boryung Reservoir Watershed)

  • 최진규;손재권;구자웅;조재영;김영주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.30-33
    • /
    • 2001
  • This study was carried out to estimate the runoff pollutant loadings for water quality management in Boryung freshwater reservoir watershed. The hydrological monitoring system were operated for water level measurement during $1999{\sim}2000$ and temporal variation of water quality constituents such as pH, EC, total nitrogen, total phosphorus were analysed, periodically. Monthly runoff volumes by TANK model and potential pollutant loadings calculated by unit method were compared with measured values.

  • PDF

저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량 (Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block)

  • 한승호;최준수;양근모;양병이;강진형;김원태
    • 한국조경학회지
    • /
    • 제34권5호
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

WAETER LEVEL CONTROL USING Z-80 MICROOMPUTER

  • Sugisaka, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1899-1903
    • /
    • 1991
  • This paper presents a water level control method using Z-80 microcomputer. The process considered in this paper is one tank system which is described by an unknown nonlinear differential equation. The water level is measured by the end of bar installed at a float passing through 8 pair of photointerrupters located at equal distance. Therefore, the input data to 8255 which is interface between Z-80 and photointerrupters is discrete value, namely, value under 1. values from 1 to 8, and value upper 8. The water is pumped into the tank from a reservoir by switching on a relay connected to a moter and pump driving system. The pumping is stopped by switching off the relay. Experimental studies for two types of controllers are performed in order to investigate the control performance of water level of the water pumping system.

  • PDF

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

조선초기의 시제와 세종의 자격루:(1) 물시계 (Horary System of the Early Chosen and the King Sejong′s Striking Clepsydra : (1) Water-Clocks)

  • 남문현;한득영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.697-701
    • /
    • 1996
  • King Sejong's Striking water-clock which brought in use on the first of July in 1434 was mainly composed of timekeeping and time announcing parts signalling twelve double-hours, and five night-watches and night-watch-divisions automatically by means of ball-operating jackworks. The clock was arranged with dual timekeeping system, the one for a full day(twelve double-hours) and the other for five night-watches achieving twelve double-hours and one-hundred interval horary systems. The vessels were arrayed in inflow-type water-clock, a large reservoir on the highest story, a constant-level tank for supplying water to the measuring vessel evenly in the middle, and the lowest tank to receive water from the above constant-level tank. An indicator-rod on the float was raised upwards depending on the water-level increase to show timing scales and also to release small bronze balls from the ball-rack mechanisms implanted on the measuring vessel to signal timing intervals.

  • PDF

Free vibration analysis of steel liquid storage tank with functionally graded column based on modified continuum mechanics

  • Cavus, Yakup Harun;Kupeli, Togay;Yayli, Mustafa Ozgur
    • Coupled systems mechanics
    • /
    • 제11권4호
    • /
    • pp.335-355
    • /
    • 2022
  • It's important to note that the number of studies on the lateral vibration of steel liquid storage tanks has been quite modest in the past. The aim of this research has to look at the variables that affect vibration of storage tanks and to highlight the characteristics of a construction that hasn't received much attention in the literature. The storage tank has pre-sized in the study, and aluminum and steel have chosen as components. The specified material qualities and the factors utilized in the investigation has used to calculate vibration frequency values. The resulting calculations are backed up by tables and graphs, and it's an important to look into the parameters that affect the vibration frequencies that will occur on the designed storage tank vary. In the literature, water tanks are usually modelled as lumped masses. The horizontal stiffness of the column on which it is placed is assumed to be constant throughout. This is an approximation method of solving this problem. The column is handled in this study with a more realistic approach that fits the continuum mechanics in the analysis. The reservoir part is incorporated directly into the problem as the boundary condition.

TANK 모형의 매개변수 추정을 위한 베이지안 접근법의 적용: MCMC 및 GLUE 방법의 비교 (Application of Bayesian Approach to Parameter Estimation of TANK Model: Comparison of MCMC and GLUE Methods)

  • 김령은;원정은;최정현;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제36권4호
    • /
    • pp.300-313
    • /
    • 2020
  • The Bayesian approach can be used to estimate hydrologic model parameters from the prior expert knowledge about the parameter values and the observed data. The purpose of this study was to compare the performance of the two Bayesian methods, the Metropolis-Hastings (MH) algorithm and the Generalized Likelihood Uncertainty Estimation (GLUE) method. These two methods were applied to the TANK model, a hydrological model comprising 13 parameters, to examine the uncertainty of the parameters of the model. The TANK model comprises a combination of multiple reservoir-type virtual vessels with orifice-type outlets and implements a common major hydrological process using the runoff calculations that convert the rainfall to the flow. As a result of the application to the Nam River A watershed, the two Bayesian methods yielded similar flow simulation results even though the parameter estimates obtained by the two methods were of somewhat different values. Both methods ensure the model's prediction accuracy even when the observed flow data available for parameter estimation is limited. However, the prediction accuracy of the model using the MH algorithm yielded slightly better results than that of the GLUE method. The flow duration curve calculated using the limited observed flow data showed that the marginal reliability is secured from the perspective of practical application.

장기 기상전망이 댐 저수지 유입량 전망에 미치는 영향 분석 (An analysis of effects of seasonal weather forecasting on dam reservoir inflow prediction)

  • 김선호;남우성;배덕효
    • 한국수자원학회논문집
    • /
    • 제52권7호
    • /
    • pp.451-461
    • /
    • 2019
  • 장기 기상전망 기반 댐 유입량 전망은 가뭄 대비, 용수 공급 관리 등에 활용성이 높다. 본 연구에서는 국내 7개 다목적댐 유역에 대해 유입량 전망을 수행하고 장기 기상전망 정확도가 댐 유입량 전망 정확도에 미치는 영향을 분석하였다. 강우-유출 모델의 입력자료로 활용된 장기 기상전망 자료는 기상청 GloSea5의 과거재현자료(hindcast) 및 미래전망자료(forecast)를 활용하였다. 강우-유출 모델은 다양한 특성을 가지고 있는 TANK, ABCD, K-DRUM, PRMS를 활용하였다. 댐 유입량 전망 정확도는 과거재현기간(1996~2009)과 미래전망기간(2015~2016)에 대하여 평가하였다. 댐 유입량 전망 평가결과 전망값은 관측값에 비해 과소추정하는 경향을 보였으며, 매개변수 검보정이 적절히 수행된 강우-유출 모델은 댐 유입량 전망 정확도에 미치는 영향이 거의 없는 것으로 나타났다. 반면 장기 기상전망 자료, 특히 강수량은 댐 유입량 전망 정확도에 매우 큰 영향을 미치는 것으로 나타났다. 현업에서 댐 유입량 전망 자료 활용시 과소추정하는 경향을 고려하여 활용할 필요가 있다. 향후 댐 유입량 전망 정확도 개선은 강우-유출 모델 보다 장기 기상전망의 강수량 정확도 향상을 위주로 수행할 필요가 있다.

지자체 농업가뭄 예·경보를 위한 미계측 저수지의 유입량 추정 및 평가 (A study on the estimation and evaluation of ungauged reservoir inflow for local government's agricultural drought forecasting and warning)

  • 최정렬;윤현철;원창희;이병현;김병식
    • 한국수자원학회논문집
    • /
    • 제54권6호
    • /
    • pp.395-405
    • /
    • 2021
  • 현재 관계부처 합동 농업가뭄 예·경보시 한국농어촌공사 관리 저수지의 관측정보만을 활용하고 있어 시군 단위 가뭄 분석 결과와 지자체 체감가뭄과의 괴리가 발생하고 있다. 지자체 단위 체감가뭄 예·경보를 위해서는 공간적으로 세밀하고 국지적인 저수지 정보가 필요하며, 이를 위해서는 전국적으로 분포된 지자체 관리 저수지 정보의 활용이 필요하다. 그러나 전국에 분포하고 있는 전체 지자체 관리 저수지에 수위 및 유량 관측 시설을 설치하는 것은 운영 및 비용 측면에서 합리적이지 않으므로 효율적인 정보 생성 방안이 필요하다. 이에 따라 본 연구에서는 관측자료가 존재하는 저수지 유역을 대상으로 장기유출 모형인 TANK 모형의 매개변수를 검·보정하고, 유역특성인자를 이용하여 그룹화 한 후 그룹화된 TANK 모형의 매개변수를 미계측 지자체 저수지 유역에 적용하여 유입량 예측 및 평가를 하였다. 평가 결과 논, 경사를 이용한 그룹의 결정계수 평균이 0.63, NSE가 0.62로, 유역면적과 유효저수량 인자를 이용했을 때(결정계수 0.49, NSE 0.47) 보다 좋은 결과를 보여주었으며, 미계측 지자체 관리 저수지 정보의 활용 가능성을 확인할 수 있었다.

GPS/GPR을 이용한 저수지 준설능력 향상 (Improve of Reservoir Dredging Ability Using GPS/GPR)

  • 이동락;홍정수;백기석;배경호
    • Spatial Information Research
    • /
    • 제14권1호
    • /
    • pp.57-65
    • /
    • 2006
  • 일반적으로 퇴적물 준설에 대한 조사는 GPS/Echo Sounder 및 Total Station/Echo Sounder를 조합한 음파탐사 방법을 이용하여 대상지의 수평위치 및 수심에 대한 관측을 실시하고 있으며, 하상의 단면계산, 저수량 및 준설계획량 등을 추정하게 된다. 이후 준설계획에 대한 계획고 및 준설토량에 대한 세부적인 계획을 수립하게 된다. 하지만 Echo Sounder를 사용하는 음파탐사 방법은 퇴적물에 대한 정확한 분포를 파악할 수 없는 단점이 있다. 본 연구는 저수지 하부의 퇴적물 및 이의 분포를 파악하여 저수지 준설계획을 수립하여 기존의 탐사방법에 대한 준설능력 향상에 중점을 두었다. 또한 기존의 음파탐사 방식과 다른 레이더탐사 장비를 이용한 GPS/GPR(Ground Penetration Radar)을 사용하여 저수지의 수평위치, 수심값을 결정하고 동시에 원지반에 분포하고 있는 퇴적물의 분포를 추정, 준설에 적용하고자 하였다. 우선 현장의 시료채취를 통한 수조모형실험을 실시하여 장비에 대한 정확도 검증을 거친 후 현장적용에 적용하여 그 가능성을 평가하였다.

  • PDF