• Title/Summary/Keyword: Research nuclear reactor

Search Result 1,697, Processing Time 0.034 seconds

COATED PARTICLE FUEL FOR HIGH TEMPERATURE GAS COOLED REACTORS

  • Verfondern, Karl;Nabielek, Heinz;Kendall, James M.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.603-616
    • /
    • 2007
  • Roy Huddle, having invented the coated particle in Harwell 1957, stated in the early 1970s that we know now everything about particles and coatings and should be going over to deal with other problems. This was on the occasion of the Dragon fuel performance information meeting London 1973: How wrong a genius be! It took until 1978 that really good particles were made in Germany, then during the Japanese HTTR production in the 1990s and finally the Chinese 2000-2001 campaign for HTR-10. Here, we present a review of history and present status. Today, good fuel is measured by different standards from the seventies: where $9*10^{-4}$ initial free heavy metal fraction was typical for early AVR carbide fuel and $3*10^{-4}$ initial free heavy metal fraction was acceptable for oxide fuel in THTR, we insist on values more than an order of magnitude below this value today. Half a percent of particle failure at the end-of-irradiation, another ancient standard, is not even acceptable today, even for the most severe accidents. While legislation and licensing has not changed, one of the reasons we insist on these improvements is the preference for passive systems rather than active controls of earlier times. After renewed HTGR interest, we are reporting about the start of new or reactivated coated particle work in several parts of the world, considering the aspects of designs/ traditional and new materials, manufacturing technologies/ quality control quality assurance, irradiation and accident performance, modeling and performance predictions, and fuel cycle aspects and spent fuel treatment. In very general terms, the coated particle should be strong, reliable, retentive, and affordable. These properties have to be quantified and will be eventually optimized for a specific application system. Results obtained so far indicate that the same particle can be used for steam cycle applications with $700-750^{\circ}C$ helium coolant gas exit, for gas turbine applications at $850-900^{\circ}C$ and for process heat/hydrogen generation applications with $950^{\circ}C$ outlet temperatures. There is a clear set of standards for modem high quality fuel in terms of low levels of heavy metal contamination, manufacture-induced particle defects during fuel body and fuel element making, irradiation/accident induced particle failures and limits on fission product release from intact particles. While gas-cooled reactor design is still open-ended with blocks for the prismatic and spherical fuel elements for the pebble-bed design, there is near worldwide agreement on high quality fuel: a $500{\mu}m$ diameter $UO_2$ kernel of 10% enrichment is surrounded by a $100{\mu}m$ thick sacrificial buffer layer to be followed by a dense inner pyrocarbon layer, a high quality silicon carbide layer of $35{\mu}m$ thickness and theoretical density and another outer pyrocarbon layer. Good performance has been demonstrated both under operational and under accident conditions, i.e. to 10% FIMA and maximum $1600^{\circ}C$ afterwards. And it is the wide-ranging demonstration experience that makes this particle superior. Recommendations are made for further work: 1. Generation of data for presently manufactured materials, e.g. SiC strength and strength distribution, PyC creep and shrinkage and many more material data sets. 2. Renewed start of irradiation and accident testing of modem coated particle fuel. 3. Analysis of existing and newly created data with a view to demonstrate satisfactory performance at burnups beyond 10% FIMA and complete fission product retention even in accidents that go beyond $1600^{\circ}C$ for a short period of time. This work should proceed at both national and international level.

Magnetite Dissolution by Copper Catalyzed Reductive Decontamination (촉매제로 구리이온을 이용한 환원성 제염에 의한 마그네타이트 용해)

  • Kim, Seonbyeong;Park, Sangyoon;Choi, Wangkyu;Won, Huijun;Park, Jungsun;Seo, Bumkyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Hydrazine based reductive dissolution applied on magnetite oxide was investigated. Dissolution of Fe(II) and Fe(III) from magnetite takes place either by protonation, surface complexation, or reduction. Solution containing hydrazine and sulfuric acid provides hydrogen to break bonds between Fe and oxygen by protonation and electrons for the reduction of insoluble Fe(III) to soluble Fe(II) in acidic solution of pH 3. In terms of dissolution rate, numerous transition metal ions were examined and Cu(II) ion was found to be the most effective to speed up the dissolution. During the cycle of Cu(I) ions to Cu(II) ions, the released electron promoted the reduction of Fe(III) and Cu(II) ions returned to Cu(I) ion due to the oxidation of hydrazine. In the experimental results, the addition of a very low amount of cupric ion (about 0.5 mM) to the solution increased the dissolution rate about 40% on average and up to 70% for certain specific conditions. It is confirmed that even though the coordination structure of copper ions with hydrazine is not clear, the $Cu(II)/H^+/N_2H_4$ system is acceptable regarding the dissolution performance as a decontamination reagent.

Protective Effects of Chemical Drugs on the Course of Uranium-induced Acute Renal Failure (우라늄오염에 의한 신부전증에 미치는 제염제의 방호효과)

  • Kim, Tae-Hwan;Chung, In-Yong;Kim, Sung-Ho;Kim, Kyeng-Jung;Bang, Hyo-Chang;Yoo, Seong-Yul;Chin, Soo-Yil
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.27-39
    • /
    • 1990
  • Appreciable radiation exposures certainly were occurred in the reactor burn-up, the nuelear fall-out and the surroundings of nuclear installations with radioactive effluents. Therefore, radioactive nuclides is not only potentially hazardous to workers of nuclear power plants and related industrials, but also the wokers who handle radioactive nuclides in biochemical research and nuclear medicine diagnostics. And in the case of occurring the nuclear accidents, the early medical treatment of radiation injury should be necessary but little is established medical procedures to decontaminate the victims of internal contamination of radioactive nuclides in korea. Accordingly, to achieve the basic data for protective roles and medical treatment of radiation injury, the present studies were carrid out to evaluate the decontamination of uranium by the chemical drugs. The results observed were summarized as follows: 1. The combined treatmet group of sodium bicarbonate and saline with uranyl nitrate injection simultaneously and the dithiothreitol group that was administered 30 minutes after uranyl nitrate injection were increased significantly in the change of body weight than uranyl nitrate-only group (P<0.005). 2. All the experimental groups were increased the fluid intake and urine volume on the uranyl nitrate-induced acute renal failure. but the combined treatment group of sodium bicarbonate and saline with uranyl nitrate injection simultaneously and the dithiothreitol group that was administered 30 minutes after uranyl nitrate injection have the higher increment of fluid intake and urine volume (P<0.05). 3. When sodium bicarbonate and saline was treated with uranyl nitrate injection simultaneously. and dithiothreitol was administered 30 minutes after uranyl nitrate injection. there was significantly reduced in BUN concentration (P<0.01). 4. When dithiothreitol was administered 30 minutes after uranyl nitrate injection. there was reduced more significantly on the increment of serum creatinine concentration than that observed in uranyl nitrate-only group(P<0.01). but when the combined treatment of sodium bicarbonate and saline with uranyl nitrate simultaneously, there was still. albeit much less marked. decrease in serum creatinine concentration. 5. The sodium bicarbonate and saline was treated with uranyl nitrate simultaneously and dithiothreitol was administered at 30 minutes after uranyl nitrate were excreted markedly higher urine creatinine concentration than the uranyl nitrate-only group. 6. Uranyl nitrate has been used in experimental animals to produce hydropic degeneration and swelling of proximal tubules, disappearance of microvilli and brush border or necrosis in the kidney and centrilobular necrosis, congestion, and telangiectasia of the liver. When the sodium bicarbonate and saline was treated with uranyl nitrate simultaneously, and dithiothreitol was administered. 30 minutes after uranyl nitrate, there was more marked the protective effect than uranyl nitrate-only group. Finally, if the sodium bicarbonate and saline may administered as quickly as possible each time that some risk for internal contamination, with uranium, and dithiothreitol is administered 30 minutes after uranium contamination, there ameliorates the course of uranyl nitrate-induced acute renal failure.and this effect is assocciated with prevention of uranium (heavy metal)-induced alterations in BUN, serum creatinine, urine creatinine, fluid intake, urine volume and body weight.

  • PDF

Analysis of High Radioactive Materials in Irradiated DUPIC SIMFUEL Using EPMA (EPMA를 이용한 DUPIC 사용후 핵연료 핵분열 생성물의 특성 분석)

  • 정양홍;유병옥;주용선;이종원;정인하;김명한
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.125-133
    • /
    • 2004
  • Fission products of DUPIC (Direct Use of Spent PWR Fuel in CANDU Reactors) fuel, irradiated in HANARO research reactor with 61 ㎾/m of maximum linear power and 1,770 ㎿d/tU of average burn-up, was characterized by EPMA(Electron Probe Micro Analyzer). In order to find accurate characterization, the analysis results by EPMA of fresh simulated DUPIC fuel containing fission products as chemicals were compared with that of wet chemical analysis. The metallic precipitates observed at the center of the fresh simulated DUPIC fuel were about 1 $\mu\textrm{m}$ in size and their major components by EPMA were Mo-53.89 at.%, Ru-37.40 at.%, and Pd+Rh-8.71 at.%. Established procedure through the fresh simulated DUPIC fuel was applied to the irradiated DUPIC fuel. Observed size of metallic precipitates were 2∼2.5 $\mu\textrm{m}$ and their compositions were Mo-47.34 at.%, Ru-46 at.%, and Pd+Rh-6.65 at.%. What are uncommon things for this experiment, special treatment for improving the conductivity was attempted to the specimen and the conditions of exact irradiation of electron beam to small metallic precipitate were suggested.

  • PDF

The Relative Effectiveness of Various Radiation Sources on the Resistivity Change in n-Type Silicon

  • Jung, Wun
    • Nuclear Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.91-101
    • /
    • 1969
  • Resistivity changes of n-type float-zone silicon crystals with 6.4$\times$10$^{14}$ to 1.25$\times$10$^{17}$ phosphorus atoms/㎤ due to irradiation by (1) 1 MeV electrons, (2) two types of research reactors, and (3) $Co^{60}$ ${\gamma}$-ray sources were investigated. The results were analyzed on the basis of a simple exponential formula derived by Buehler. While the formula gave a fair fit in the low fluence range in most cases, the deviation was quite appreciable in the case of 1 MeV electron irradiation, and a linear change gave better fit in some cases. The large change in the carrier removal rate in electron-irradiated samples in the high fluence range was analyzed in detail in terms of the Fermi level cross-over of the defect levels. Based on the damage constants evaluated from the initial portion of data where the formula was applicable, the relative effectiveness of various radiation sources in causing the resistivity change in n-type silicon was compared. The TRIGA Mark II reactor neutrons, for example, were found to be about 40 times more effective than 1 MeV electrons. The dependence of the damage constant on the initial carrier concentration was also examined. The physical basis of the exponential law and the effect of the Fermi level cross-over of the defect levels on the resistivity change in the high fluence ranges are discussed.

  • PDF

Study of the Electrolytic Reduction of Uranium Oxide in LiCl-Li$_{2}$O Molten Salts with an Integrated Cathode Assembly

  • Park Sung-Bin;Seo Chung-seok;Kang Dae-Seung;Kwon Seon-Gil;Park Seong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 2005
  • The electrolytic reduction of uranium oxide in a LiCl-Li$_{2}$O molten salt system has been studied in a 10 g U$_{3}$O$_{8}$ /batch-scale experimental apparatus with an integrated cathode assembly at 650$^{\circ}C$. The integrated cathode assembly consists of an electric conductor, the uranium oxide to be reduced and the membrane for loading the uranium oxide. From the cyclic voltammograms for the LiCl-3 wt$\%$ Li$_{2}$O system and the U$_{3}$O$_{8}$-LiCl-3 wt$\%$ Li$_{2}$O system according to the materials of the membrane in the cathode assembly, the mechanisms of the predominant reduction reactions in the electrolytic reactor cell were to be understood; direct and indirect electrolytic reduction of uranium oxide. Direct and indirect electrolytic reductions have been performed with the integrated cathode assembly. Using the 325-mesh stainless steel screen the uranium oxide failed to be reduced to uranium metal by a direct and indirect electrolytic reduction because of a low current efficiency and with the porous magnesia membrane the uranium oxide was reduced successfully to uranium metal by an indirect electrolytic reduction because of a high current efficiency.

  • PDF

Correlation of $^{137}Cs/^{60}Co$ Activity Ratio in Radwaste with Primary Coolant (원자로 냉각재와 방사성폐기물 내 $^{137}Cs/^{60}Co$ 핵종비)

  • Jee, Kwang-Yong;Park, Yeong-Jae;Pyo, Hyung-Yeol;Ahn, Hong-Joo;Kim, Won-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.9-17
    • /
    • 2007
  • In order to compare the correlation of radioactivity ratio between the radwaste streams and the primary coolant of PWR NPPs, A RCS sampling kit was installed to primary coolant system for the collection of the radionuclides during the normal operation of NPPs. RCS samples were collected from PWR type of domestic NPPs through 2004 to 2005, and pretreated with acid microwave digestion or leaching method to assay quantitatively of several interesting radionuclides. The radioactivity ratios of $^{137}Cs\;to\;^{60}Co$ in a filter cartridge and a resin cartridge were 2.3E-2 and 7.3E-1, respectively. At a same period of the reactor operating cycle, the radioactivity ratios of $^{137}Cs\;to\;^{60}Co$ were 6.3E-1 for a evaporator bottom, 6.7E-1 for a spent resin, and 5.6E-2 for a dry active waste, so that these radwaste streams were identified as having similar characteristics with the corresponding RCS samples.

  • PDF

Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient (암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석)

  • Lee, Chang-Hee;Choi, Jung-Eun;Kim, Sun-Ha;Chung, Yong-Sam;Moon, Jong-Hwa;Yoo, Hwa-Seung
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.1
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels (EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Kim, Hee-Moon;Park, Jong-Man;Kim, Myung-Han
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.355-362
    • /
    • 2004
  • Fission products and Inter reaction layer of $U_3Si-Al$ dispersion fuel, irradiated in HANARO research reactor with 121 kW/m of maximum liner power and 63 at% of average burn-up, was characterization by EPMA (Electron Probe Micro Analyzer). The fuel punching system developed by Irradiated Materials Examination Facility (IMEF) has used to make these samples for the EPMA. With this system a very small and thin specimen which is 1.57 mm in diameter and 2 mm in thickness respectively has been fabricated to protect the EPMA operator from high radioactive fuel and to mini-mize the equivalent dose rate less than 150 mSv/h. EPMA was performed to observe layers of sectional, Inter-reaction and oxide with specimens of cutting and polished. Stoichiometry in the Inter-reaction layer with $16{\mu}m$ of thickness was $U_{2.84}$ Si $Al_{14}$ with calibration of $UO_2$ and $U_{3.24}$ Si $Al_{14.1}$ with calibration of standard specimen. metallic precipitates in this layer were not observed using fission products examination.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.