• Title/Summary/Keyword: Research guide

Search Result 2,292, Processing Time 0.025 seconds

Percutaneous femoral access: Stuck guide wire, decannulation difficulty due to unravelling and knotting

  • Bhanu Pratap Singh Chauhan;Binita Dholakia;Ashfaque Khan;Chirag Hirani;Satheesh Kumar;Dibya Jyoti Mahakul;Abhishek Katyal;Wajid Nazir;Daljit Singh
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.223-226
    • /
    • 2024
  • Percutaneous techniques for femoral arterial access are increasingly being performed due to advances in endovascular cerebral procedures, as they provide a less morbid and minimally invasive approach than open procedures. Common complications associated with this peripheral puncture include hematoma, bleeding, pseudoaneurysm, arteriovenous fistula, retroperitoneal bleeding, inadvertent venous puncture, dissection, etc. The retrograde femoral access is currently the most frequently used arterial access as it is technically straightforward, allows for the use of larger size sheaths and catheters, allows repeated attempts, etc. Although being technically less challenging, grave complications can occur due to hardware failure. Here, we present a case of unruptured posterior inferior cerebellar artery (PICA) aneurysm, who underwent uneventful diagnostic cerebral digital substraction angiography (DSA) via right femoral artery route on first attempt, but on second attempt for therapeutic intervention, landed up with stuck guide wire and faced decannulation difficulty due to unravelling of guide wire and multiple knot formation, which was finally removed after multiple attempts at pulling and improvised manoeuvres. Such cannulation and decannulation difficulties have been reported multiple times for central venous access, but extremely rarely for femoral routes, making this case a rarity and worth reporting.

Elementary School Teachers' Perceptions and Needs for an Elementary School Science Teacher's Guide in Details (초등 과학 교사용 지도서 각론에 대한 초등교사들의 인식과 요구)

  • Chang-Hee Jung;Jeongwoo Son
    • Journal of Science Education
    • /
    • v.47 no.2
    • /
    • pp.117-126
    • /
    • 2023
  • In an elementary school science teacher's guide, the guide in details that can help elementary school teachers with difficulties when preparing and conducting science classes are essential. To gain insights into the development of the 2022 revised curriculum elementary school science teacher's guide, it is necessary to investigate the perceptions and needs of elementary school teacher's guide in details. In this study, we developed a questionnaire by analyzing the components and design of an elementary school science teacher's guide in details to explore elementary school teachers' perceptions and needs. For this purpose, we first investigated elementary school teachers' perceptions of their needs, satisfaction, and the utilization of each component of the current guide in details. Next, we investigated teachers' needs regarding the specific components and design of a guide. The findings were as follows. First, elementary school teachers were delighted with the components that help them prepare and conduct lessons. Second, elementary school teachers wanted an easy-to-read design with a layout that allowed them to see the components they needed for their lessons at a glance. In conclusion, the elementary school science teacher's guide in details to be readable and organized to provide at-a-glance information on lesson preparation, lesson flow, and teaching and learning materials needed for science teaching-learning. Based on the results of this study, new approaches and attempts should be made to develop a textbook that elementary school teachers can utilize in the future.

The Cooling Characteristics for Circular Irradiation Hole under Suppressing Jet Flow at Guide Tube in HANARO (안내관 제트유동 억제시의 하나로 원형 조사공의 냉각특성)

  • Wu S. I.;Park P. C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.208-213
    • /
    • 2004
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in- pool type, is under normal operation since it reached the initial critical in February 1995. The HANARO is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and is under developing a target handling tool for loading and unloading it in a circular flow tube (OR-5). A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to calculate the hole size of a orifice inserted in the circular irradiation hole and to study the flow characteristics through the guide tube under reactor normal operation and loading the target. As results, the results show that the hole size of orifice was 31 mm of the inner diameter to suppress the guide tube jet flow and the coolant safely cooled the target of fission moly after inserting the orifice to the flow tube.

  • PDF

The Analytic Analysis of Suppressing Jet Flow at Guide Tube of Circular Irradiation Hole in HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y. C.;Wu S. I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.214-219
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve m (12 m) depth of the reactor pool and cold by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and exit through the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be Quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to study the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, about fourteen kilogram per second (14 kg/s) suppressed the guide tube jet and met the design cooling flow rate in a circular flow tube, and that the fission moly target cooling flow rate met the minimum flow rate to cool the target.

  • PDF

FLOW DISTRIBUTION IN THE CORE OF HANARO AFTER SUPPRESSING THE JET FLOW IN THE GUIDE TUBE USED FOR LOADING FISSION MOLY TARGET (Fission Moly 표적을 장전하기 위한 안내관의 제트유동 억제 후 하나로 노심 유량분포)

  • Park Yong Chul;Lee Byung Chul;Kim Bong Soo;Kim Kyung Ryun
    • Journal of computational fluids engineering
    • /
    • v.10 no.4 s.31
    • /
    • pp.66-71
    • /
    • 2005
  • HANARO, a multi-purpose research reactor, 30 MWth open-tank-in-pool type, is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and a target handling tool is under development for loading and unloading it in a circular flow tube (OR-5) of HANARO. A guide tube is extended from the reactor core to the top of the reactor chimney for easily loading the target under a normal operation of the reactor. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube. The jet flow was suppressed in the guide tube after reducing the inner diameter of a flow restriction orifice installed in the OR-5 flow tube for adding the pressure difference in the flow tube. This paper describes an analytical analysis to calculate the flow distribution in the core of HANARO after suppressing the jet flow of the guide tube. As results, it was confirmed through the analysis results that the flow distribution in the core of HANARO were not adversely affected.

Flow Distribution in the Core of the HANARO After Suppressing the Jet Flow in the Guide Tube used for Loading Fission Moly Target. (Fission Moly 표적을 장전하기 위한 안내관의 제트유동 억제 후 하나로 노심유량분포)

  • Park Yong-Chul;Lee Byung-Chul;Kim Bong-Soo;Kim Kyung-Ryun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.70-73
    • /
    • 2005
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and is under developing a target handling tool for loading and unloading it in a circular flow tube (OR-5). A guide tube is extended from the reactor core to the top of the reactor chimney for easily loading the target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube. The jet flow was suppressed in the guide tube after reducing the inner diameter of a flow restriction orifice installed in the OR-5 flow tube for adding the pressure difference in the flow tube after unloading the target. This paper describes an analytical analysis to calculate the flow distribution in the core of the HANARO after suppressing the jet flow of the guide tube. As results, it was confirmed through the analysis results that the flow distribution in the core of the HANARO were not adversely affected.

  • PDF

THE ANALYTIC ANALYSIS OF SUPPRESSING JET FLOW AT GUIDE TUBE OF CIRCULAR IRRADIATION HOLE IN HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y.C.;Wu S.I.
    • Journal of computational fluids engineering
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed af inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and comes out from the outlet of chimney. A fission moly guide tube is extended from the reactor core to the top of the reactor chimney for easily loading a fission moly target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, reduced to about fourteen kilogram per second (14 kg/s) from the original flow rate of sixteen point three kilogram per second (16.3 kg/s) did not show the guide tube jet.

Flow Characteristics for Guide Tube of Circular Irradiation Hole in HANARO (하나로 원형 조사공의 안내관 유동특성)

  • Park, Y.C.;Wu, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1835-1840
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum,. rises up through the grid plate and the core channel and comes out from the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by a jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the guide jet is suppressed under the top of the chimney after modifying the orifice diameter of 37.5 mm to 31 mm.

  • PDF

Improvement on the Method of Estimating Radionuclide Concentrations in Agricultural Products for the Off-Site Internal Dose Calculation for Operating Nuclear Facilities (가동중 원자력 시설 주변 주민의 내부피폭선량 계산을 위한 농산물내 핵종 농도 평가법 개선)

  • Choi, Y.H.;Lim, K.M.;Hwang, W.T.;Choi, G.S.;Choi, H.J.;Lee, C.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.73-90
    • /
    • 2004
  • The Reg. Guide 1.109 model was reviewed against its applicability to calculating radionuclide concentrations in agricultural products for operating nuclear facilities and an improved method was proposed. The model was so modified that the radionuclides deposited since the start of operation could be considered in assessing the root uptake. Translocation factors were introduced in the equation for calculating the concentrations in edible parts due to direct plant deposition. Values specific to Korea were set up for the input parameters of the modified model. The concentrations of $^{54}Mn,\;^{60}Co,\;^{90}Sr\;and\;^{137}Cs$ in rice seeds, Chinese cabbage and radish root were calculated for various hypothetical deposition histories using the Reg. Guide 1.109 model and the modified model with parameter values in the guide and those specific to Korea put in alternately. Through comparisons among the results, it could be expected that the use of the modified model with the input of parameter values specific to Korea would result In a more resonable and realistic assessment.

A Study in the Medical Service Improvement at University Hospitals with Concentration upon Life in Hospital Guide (입원환자의 의료질 향상(QI)을 위한 입원생활 안내문의 효과)

  • Park, Sun-Kyung;Han, Sang-Sook;Paik, Seung-Nam
    • Journal of East-West Nursing Research
    • /
    • v.9 no.1
    • /
    • pp.74-82
    • /
    • 2004
  • Purpose: This study has been conducted as a quality improvement activity in order to confirm the assessment of patients, their guardians and nurses by providing them with a Life in Hospital Guide. Method: Nursing with Life in Hospital Guide provision was conducted at an University Hospital with patients admitted within 5 days or less and their guardians, a control group of 375 persons and a comparison group of 372 persons, and the data have been collected from the 26th of May to the 10th of October 2003. A Life in Hospital Guide, in the form of a leaflet, that contained useful information such as meals, facilities, car parking, documents, linen products etc, was used. The collected data have been analysed using SPSS windows programme 11.0 for percentage, $X^2$-test, and t-test. Result: The comparison group who were provided with a Life in Hospital Guide will know better about the articulars needed to live in hospital than the control group who were not,' the average of the comparison group (4.04) was higher than the control group (3.04), which is a significant difference (t=-27.06, p=.000). Conclusion: As a results of this study, it was confirmed that life in hospital guidance through a leaflet each as a quality improvement activity, are effective.

  • PDF