• Title/Summary/Keyword: Research Recording

Search Result 880, Processing Time 0.028 seconds

Changes in the Modulation Amplitude and the Particle Sizes of Co/Pd Multilayers During Stress Release and Interdiffusion

  • Kim, Jai-Young;Evetts, Jan-E
    • Journal of Magnetics
    • /
    • v.3 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • An artificially modulated magnetic Co/Pd multilayer is one of the promising candidates for high density magneto-optic (MO) recording media, due to large Kerr rotation angle in the wavelength of a blue laser beam. however, since multilayer structure, as well as amorphous structure, is a non-equilibrium state in terms of free energy and MO recording is a kind of thermal recording which is conducted aound Curie temperature (Tc) of the recording media, when the multilayer is used for the MO recording media, changes in the multilayer structure are occurred as the amorphous structure do. Therefore, the assessment of the structural stability in the Co/Pd multilayer is crucially important both for basic research and applications. As the parameter of the structural stability in this research, modulation amplitude and particle size of the Co/Pd multilayer are measured in terms of Ar sputtering pressure and heat treatment temperature. From the results of the research, we find out that the magnetic exchange energy in the structural changes of a magnetic multilayer structure and suggest the operating temperature range for MO recording in the Co/Pd multilayer for the basic research and applications, respectively.

  • PDF

MICROSTRUCTURE AND NOISE CHARACTERISTICS IN Co-Cr BASED ALLOY THIN FILM MAGNETIC RECORDING MEDIA

  • Koshimoto, Y.;Hirono, S.;Ohkubo, T.;Umemura, S.;Maeda, Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.690-694
    • /
    • 1995
  • Reducing media noise is a key to realizing high areal recording density. However, perpendicularly oriented Co-Cr films, stong candidates for high density recording media, have received little attention in terms of recording noise. We studied the noise characteristics of Co-Cr based alloy films by varying the compositionally separated structure. Co-Cr films with fine compositionally separated microstructure were observed to have low noise, which recording density dependence were negative or week. Studies on control of the microstructure and magnetic properties in combination with noise analysis are important to realize high density recording media.

  • PDF

Development of a Broadband Self-recording Hydrophone

  • Kim, Bong-Chae
    • Ocean and Polar Research
    • /
    • v.28 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • A broadband self-recording hydrophone was developed to conveniently assemble a hydrophone array for use in receiving underwater sound waves. A trigger device with an electromagnetic induction coupler was also developed to control the hydrophone's operation. Main configurations and specifications of the self-recording hydrophone are introduced in this paper. We present experiment results conducted in a water tank to examine the operating behavior of the hydrophone. Some advantages are discussed when the self-recording hydrophones are used to make up a hydrophone array.

Signal Processing for Perpendicular Recording Systems

  • Lee, Jun;Woo, Choong-Chae
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.70-75
    • /
    • 2011
  • Longitudinal recording has been the cornerstone of all two generations of magnetic recording systems, FDD and HDD. In recent, perpendicular recording has received much attention as promising technology for future high-density recording system Research into signal processing techniques is paramount for the issued storage system and is indispensable like longitudinal recording systems. This paper focuses on the performance evaluation of the various detectors under perpendicular recording system. Parameters for improving the their performance are examined for some detectors. Detectors considered in this work are the partial response maximum likelihood (PRML), noise-predictive maximum likelihood (NPML), fixed delay tree search with decision feedback (FDTS/DF), dual decision feedback equalizer (DDFE) and multilevel decision feedback equalizer (MDFE). Their performances are analyzed in terms of mean squared error (MSE) and noise power spectra, and similarity between recording channel and partial response (PR) channel.

Annealing Effect of Co/Pd Multilayers on Magnetic Properties During Interdifusion

  • Kim, Jai-Young;Jan E. Evetts
    • Journal of Magnetics
    • /
    • v.2 no.4
    • /
    • pp.147-156
    • /
    • 1997
  • An artificially modulated magnetic Co/Pd multilayer is one of the promising candidates for high density magneto-optic (MO) recording media, due to a large Kerr rotation angle in the wavelength of a blue laser beam. However, since multilayer structure, as well as amorphous structure, is a non-equilibrium state in terms of free energy and a MO recording technology is a kind of thermal recording which is conducted around Curie temperature (Tc) of the recording media, when the Co/Pd mulilayer is used for the MO recording media, changes in the magnetic properties are occurred as the amorphous structure do. Therefore, the assessment of the magnetic properties in the Co/Pd multilayer during interdiffusion is crucially important both for basic research and applications. As the parameter of the magnetic properties in this research, saturation magnetization and perpendicular magnetic anisotropy energy of the Co/Pd multilayer are measured in terms of Ar sputtering pressure and heat treatment temperature. Form the results of the research, we find out that the magnetic exchange energy between Co and Pd sublayers strongly affects the changes in the magnetic properties of the Co/Pd multilayers during the interdiffusion in ferromagnetic state. This discovery will provide the understanding of the magnetic exchange energy in the Co/Pd multilayer structure and suggest the operating temperature range for MO recording in the Co/Pd multilayer for the basic research and applications, respectively.

  • PDF

Simple Near-Field Optical Recording Using Bent Cantilever Probes

  • Kim, Jeong-Yong;Song, Ki-Bong;Park, Kang-Ho;Lee, Hyo-Won;Kim, Eun-Kyoung
    • ETRI Journal
    • /
    • v.24 no.3
    • /
    • pp.205-210
    • /
    • 2002
  • This paper describes our high-density near-field optical recording using bent cantilever fiber probes installed in an atomic force microscope. We conducted a near-field reading of nano-scale hole patterns with a 100 nm spatial resolution and a 25 ${\mu}m$/s scan speed; this implies a capability of a data reading density of 60 Gb/$in^2$ with a 0.25 kbps data transfer rate. In addition, we investigated re-writable near-field recording on photochromic diarylethene films. We successfully recorded erasable memory bits having a minimum width of 600 nm in a writing time as short as 30ms. We found that using a cantilever probe simplifies the setup and operation of the near-field optical recording system and may offer multifunctional recording capabilities.

  • PDF

Multi-Functional Probe Recording: Field-Induced Recording and Near-Field Optical Readout

  • Park, Kang-Ho;Kim, Jeong-Yong;Song, Ki-Bong;Lee, Sung-Q;Kim, Jun-Ho;Kim, Eun-Kyoung
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2004
  • We demonstrate a high-speed recording based on field-induced manipulation in combination with an optical reading of recorded bits on Au cluster films using the atomic force microscope (AFM) and the near-field scanning optical microscope (NSOM). We reproduced 50 nm-sized mounds by applying short electrical pulses to conducting tips in a non-contact mode as a writing process. The recorded marks were then optically read using bent fiber probes in a transmission mode. A strong enhancement of light transmission is attributed to the local surface plasmon excitation on the protruded dots.

  • PDF

A study on the method of the personnel recording of DHRMIS (국방인사정보체계의 인사기록방법에 관한 연구)

  • Cho, Young-Pyong;Yang, Hae-Sool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.2
    • /
    • pp.88-99
    • /
    • 2008
  • In this article, DHRMIS being developed with ERP at resent realizes the personnel affairs recording procedures that all the Ministry of National Defense, the army, the navy and the air force can use on personnel affairs in order to solve the problem of the personnel recording procedures of the MND and each of the troops such as using manual affairs together with computation affairs, absence of electronic recording managements in some of the institutions MND, insufficiency of real time recording, and excess of centralized managements to present and record the personnel data. The personnel recording procedures consist of standardized personnel recording procedures and definition of the personnel recording procedures. This personnel recording procedures propose 3 improvements such as an atomic electronic recording management, a real time recording affair, effective centralization and distribution of verification authority so as to guarantee authentication, integrity, reliance, and accessibility of personnel data. When proposed personnel recording procedures are realized through developing DHRMS, these can bring on unification of 10 recording management systems, reduction of recording management time from 45 days to 3 days, distribution of verification authority MND, each of the troops, each of the institutes, an individual, and reduction of some of the manual documents.

  • PDF

Measurement of Low-Frequency Ocean Noise by a Self-Recording Hydrophone (자동기록식 수중청음기를 이용한 저주파 해양잡음의 측정)

  • Kim, Bong-Chae;Kim, Byoung-Nam;Cho, Hong-Sang
    • Ocean and Polar Research
    • /
    • v.29 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Ocean noise may be used for monitoring wind speed and rainfall rate on the sea surface, as well as for tracking whales' migration routes. In particular, low-frequency ocean noise has recently been of concern with relation to the behavior of marine mammals. Low-frequency ocean noise has been increasing over the past few decades due to increase of ship traffic and offshore oil industry activities. Mechanical noise such as flow noise and cable strumming noise may be induced if low-frequency ocean noise is measured by cabled traditional hydrophone in high current areas. To successfully measure low-frequency ocean noise in a shallow water environment with strong current, we developed a self-recording hydrophone. This paper describes the main configurations of the self-recording hydrophone and presents some results on measured data.