• Title/Summary/Keyword: Research Performance Evaluation

Search Result 5,466, Processing Time 0.037 seconds

An Empirical Analysis of Industrial Design′s Functional Role in the Causal Model of Quality Competitiveness : Korean Manufacturing Sector (품질경쟁력 인과모형 하에서 산업디자인의 기능적 역할에 관한 실증적 분석 : 한국 제조업 부문을 중심으로)

  • 임채숙;윤종영
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.111-122
    • /
    • 2004
  • The purpose of this study are two the first is to identify the positioning of product design and analyze its functional relationship with product development, manufacturing, marketing and sales in the comprehensive competitiveness evaluation model ; and the second is to estimate the determinants of QCI(quality competitiveness index), analyze the impact of product design on QCI, and compare the aforementioned results for the seven industrial sectors and the five product patterns. For this empirical analysis, this study surveyed 400 Korean manufacturing firms during August-October 2003. The major empirical findings are summarized as follows : First, the hypothesis on the positive effect of product design on QCI is accepted at a highly significant level (p < 0.001) for all : the manufacturing sector, seven industrial sectors, and five product categories. Second, the correlation analysis and factor analysis lead to the result that the effect of product design on QCI is estimated to be relatively very low, in comparison to those of product functionality and basic performance on QCI. These findings imply that Korean manufacturing sector has been still in the prematured stage at which product design has not played an important role yet. This study concludes that product design in line with other functions (product development, manufacturing, marketing, and sales) should make a good contribution to the improvement of QCI in the future.

  • PDF

An Experimental Study for Performance Evaluation in Dogs of Preventive Contrast Media Extravasation with a Strain Gage Based Prototype Extravasation Detection Accessory System (잡견에서 조영제 혈관외유출 예방을 위한 스트레인 게이지 기반의 EDA 시스템 성능 평가를 위한 실험적 연구)

  • Kweon, D.C.;Yoo, B.G.;Lee, J.S.;Cho, M.S.;Yang, S.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • The major risk associated with the use of automated power injectors is the well known complication of contrast material extravasation at the injection site. Automated injection of computed tomography (CT) contrast media can produce the compartment syndrome. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The extravasation detection accessory (EDA) system was composed of a strain gage, an amplifier and a computer based system. A strain gage pliable adhesive patch was applied to the skin aver the intravenous catheter and the catheter was connected to the power injector with a cable to monitor the resolution data. If the programmed monitoring, which was developed with MS Visual C++, at the extravasation occurred, then the injection was interrupted the auto injector. CT was used to demonstrate the clinically important extravasation. This study was a prospective, observational study in which the EDA system was used to monitor the automated mechanical injection of contrast material in 7 dogs. There were two true-positive cases (range of extravasation volumes: $18{\sim}22ml$), twenty three true-negative cases, three false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 88% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors. The EDA system is easy to use safe and accurate for the monitoring extravasation of the intravenous injections, and this system may prove especially useful in CT applications.

A Study on the Elaboration of Request for Proposal of Localization Parts using AHP method (AHP 기법을 적용한 부품국산화 제안요청서 정교화 연구)

  • Song, Hyeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • The purpose of this study is to elaborate the request for proposal (RFP) for the localization parts development support project of core parts carried out by the Defense Agency for Technology and Quality. The RFP is the most important document throughout the localization parts project, including project announcement and developer selection, design and test of the development product, final evaluation, and standardization of the project. However, if the RFP is not established at the beginning of the project, there is an increased risk of business failure due to frequent changes by various reasons. In this study, we recognized the necessity of elaboration of RFP and applied the AHP method for quantitative elaboration. Eight requirements of the RFP related to the mechanical/electrical performance of localized development products and three elaboration methods for each requirement were designed in a hierarchical structure, and each weight was calculated by applying the 5-point scale AHP method. The AHP survey was conducted with 20 developers participating in the localization parts project, and the consistency ratio of the AHP survey result was less than 0.1. The elaboration method with the highest value among the calculated weights is classified, and the analysis results and future research directions of the elaboration method are presented.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 무선 센서네트워크 환경구축을 위한 무선 스펙트럼 분석 및 전송시험에 관한 연구)

  • An, Tea-Ki;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3220-3226
    • /
    • 2011
  • In order to monitor internal risk factors such as fire, terror, etc. on the subway station, the surveillance systems using CCTV and various kinds of sensors have been implemented and recently, introduction of surveillance systems using an advanced IT technology, sensor network technology is tried on several areas. Since 2007, Korean government has made an effort to develop the intelligent surveillance and monitoring system, which can monitor fire, intrusion, passenger congestion, health-state of structure, etc., by using wireless sensor network technology and intelligent video analytic technique. For that purpose, this study carried out field wireless communication environment test on Chungmuro Station of Seoul Metro on the basis of ZigBee that is considered as a representative wireless sensor network before field application of the intelligent integrated surveillance system being developed, arranged and analyzed and ZigBee based wireless communication environment test results on the platform and waiting room of Chungmuro Station on this paper. Results of wireless spectrum analysis on the platform and waiting room showed that there is no radio frequency overlapped with that of ZigBee based sensor network and no frequency interference with adjacent frequencies separated 10MHz or more. As results of wireless data transmission test using ZigBee showed that data transmission is influenced by multi-path fading effect from the number and flow rate of passengers on the platform or the waiting room rather than effects from entrance and exit of the train to/from the platform, it should be considered when implementing the intelligent integrated surveillance system on the station.

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Evaluation for Adhesion Characteristics of UV-curable Bump Shape Stamp for Transfer Process (전사공정을 위한 UV 경화성 범프형 스탬프의 점착특성 평가)

  • Jeong, Yeon-Woo;Kim, Kyung-Shik;Lee, Chung-Woo;Lee, Jae-Hak;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.32 no.3
    • /
    • pp.75-81
    • /
    • 2016
  • Future electronics such as electronic paper and foldable cellphone are required to be flexible and transparent and should have a high performance. In order to fabricate the flexible electronics using flexibility transfer process, techniques for transferring various devices from rigid substrate onto flexible substrate by elastomeric stamp, have been developed. Adhesion between the elastomeric stamp and various devices is crucial for successful transfer process. The adhesion can be controlled by the thickness of the stamp, separation velocity, contact load, and stamp surface treatment. In this study, we fabricated the bump shape stamp consisting of a UV-curable polymer and investigated the effects of curing condition, separation velocity, and contact load on the adhesion characteristics of bumps. The bumps with hemispherical shape were fabricated using a dispensing process, which is one of the ink-jet printing techniques. Curing conditions of the bumps were controlled by the amount of UV irradiation energy. The adhesion characteristics of bumps are evaluated by adhesion test. The results show that the pull-off forces of bumps were increased and decreased as UV irradiation energy increased. For UV irradiation energies of 300 and 500 mJ/cm2, the pull-off forces were increased as the separation velocity increased. The pull-off forces also increased with the increase of contact load. In the case of UV irradiation energy above 600 mJ/cm2, however, the pull-off forces were not changed. Therefore, we believe that the bump shape stamp can be applied to roll-based transfer process and selective transfer process as an elastomeric stamp.

The Evaluation of UWB Wireless Communication Position Determination Function in an Enclosed Space for Fire Fighting (소방활동을 위한 밀폐공간 무선통신 측위성능 평가)

  • Kim, Dong-Hyun;Kim, Chung-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.117-122
    • /
    • 2017
  • The absence of fire fighters' connection to communication can bring about increased loss of life due to errors and delays in rescue and actions and danger to their own safety. Therefore, when communication infrastructure has been destroyed in an enclosed space, it is necessary to set up an emergency wire or wireless telecommunication environment to fire fighting and to secure safer environment to deal with the disaster by checking the location of fire fighters. In this research, for the establishment communication environment in an enclosed inside using Ultra-Wide Band (UWB) wireless communication network, the performance of communication position determination of a single UWB communication module was evaluated regarding 6 kinds of indoor surroundings. When the communication distance in an indoor environment of each 6 channels bandwidth of UWB communication frequency was measured, the results were as follows: the open space (Ave. 15.5 m, Max. 20 m), the corridor (Ave. 17.33 m, Max 20 m), inside retaining home furnishings (Ave. 15.3 m, Max. 20 m), vertical stairs (Ave. 4.33 m, Max. 6 m), horizontal space with a closed fire door (Ave. 6.5 m, Max. 17 m). It was also found out that the communication function and the distance function were best in the frequency range from 6489.6 to 1081.6 MHz by 7 Ch. Accordingly, the establishment of communication environment in an enclosed space is judged to be possible when UWB communication module is set up at 20 m apart and multiple channels are used.

Evaluation of the Impact of Fuel Economy by Each of Driving Modes for Medium-Size Low-Floor Bus (중형저상버스의 개별주행모드에 따른 연료소비율 평가)

  • Jung, Jae-wook;Ro, Yun-sik;Ahn, Byong-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.133-140
    • /
    • 2016
  • The Ministry of Land, Infrastructure and Transport has introduced low-floor buses, which are convenient for passengers getting on and off the bus and for the handicapped. The standard bus model is 11 m long and uses compressed natural gas (CNG). However, this model has drawbacks in narrow rural road conditions such as those in farming and fishing villages and mountainous areas, as well as difficulty in refueling since CNG facilities are not readily available. In this study, running resistance values were obtained by coasting performance tests on actual roads using a Tata Daewoo LF-40 model with three different weight conditions: curb vehicle weight (CVW), half vehicle weight (HVW), and gross vehicle weight (GVW).The test methods include WHVC, NIER-06, and constant-speed driving at 60 km/h. These tests were used to measure the fuel economy of vehicles other than the target vehicles to obtain the combined fuel economy. The energy efficiency was highest in the case of CVW. In the WHVC mode, the fuel consumption rates of HVW and GVW were typically 3.5% and 12% higher than that of CVW, respectively. In constant-speed driving, the fuel efficiency of HVW was higher than that of CVW. Further research is required to analyze the exhaust gas data.