• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.035 seconds

A Study on Facilities Planning for Recreational Fishing Complexes (바다낚시복합타운 시설계획에 관한 연구)

  • Kang, Young-Hun;Lee, Han-Seok
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.431-440
    • /
    • 2016
  • This paper suggests facility planning ideas for recreational fishing complexes suitable for family anglers. Existing recreational fishing parks are only equipped with facilities for angling. There are many needs for recreational fishing complexes in coastal fishing villages that include not only angling facilities but also various marine leisure and sports facilities. In this paper we suggest concepts for recreational fishing complexes and define four types of complexes in terms of facilities planning. These four types of complexes are: 1) suburban leisure sports, 2) suburban healing and relaxation, 3) penturban experience and activities, and 4) penturban culture and recreation. Then we propose facility composition in detail for each type. Also we suggest site selection criteria for the village complex, facility infrastructure planning ideas, and leisure facilities (elementary and specialized) for recreational fishing complexes.

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Suggestions on the Campus FM Services by Establishing Framework in the form of Performance Indicator(Pi) Based on FM_KS (KS 시설관리 표준규격을 바탕으로 한 대학시설 FM 서비스 발전방향)

  • Shin, Eun-Young;Kim, Yu-Jin;Kim, Jun-Ha
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.1
    • /
    • pp.37-45
    • /
    • 2015
  • Over the years, great attention has been shown to the function of the campus facilities that should be well-equipped, operated and maintained to better support university's two main goals: providing education and supporting research. Properly managing campus facilities is the initial step to be prepared to meet the rapidly changing global educational standard. However, so far, no definitive answer has been given to the question of what service level/scope is appropriate for the effective campus facility management (FM) in Korea. Therefore, at the outset, it is imperative to establish the framework for the standardized campus FM services. The main focus of this research is to provide comprehensive understanding on the campus FM by establishing the framework in the form of FM performance indicator (PI). As the first step, FM standards set by Korean Agency for Technology and Standards (KATS) has been thoroughly reviewed and analyzed to establish the framework for FM standards applicable to campus facility management. Secondly, extensive literature review on the development of performance indicator (PI) for the educational facilities has been conducted to classify PI types and complement FM_KS. Finally, specific guideline and PIs developed by APPA which is globally well-known association in the field of FM for higher education facilities has been added to the combined PI which is the mixed form of FM_KS and PIs from the previous literature. This research provides campus facility managers and FM outsourcing service providers with framework in the form of PI to support future directions of effective campus FM services.

A Study on Classification Standard for Efficient Maintenance System of Educational Facilities (교육시설물의 효율적 유지관리 체계정립을 위한 분류 기준연구)

  • Kim, Song-Hwa;Kim, Sung-Kyum;Cho, Chang-Yeon;Son, Jae-Ho;Kim, Jae-On
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.403-407
    • /
    • 2007
  • Korean Government conducted "a research for establishing the integrated construction information classification system" and suggested the classification system for the first and second level in terms of the complexity in May, 2001. The Ministry of Construction and Transportation announced a standard of the integrated construction information classification system using previous research in August, 2001. Since 2005, many BTL projects have been constructed for the educational facility. However, there is mixed official standard of the system for the educational facility. Moreover, it is difficult for the SPC to use the current "integrated construction information classification system", since the item in the educational facility cannot be easily located in the current system. Thus, this research suggests an efficient maintenance system for the educational facility. Two classification systems, space-oriented and element-oriented systems, are suggested to increase efficiency of the classification system.

  • PDF

A Starting Characteristics Study of the Scramjet Engine Test Facility with a Mach 5.0 Nozzle (마하 5.0 노즐을 장착한 스크램제트 엔진 시험설비의 시동 특성 연구)

  • Lee, Yang-Ji;Yang, In-Young;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.63-72
    • /
    • 2013
  • A Mach 5 nozzle and a diffuser of the Scramjet Engine Test Facility (SETF) were made for a hydrocarbon-fueled scramjet engine. SETF, attached with a diffuser guide, started with a model of 60% blockage, though the model engine could not start by over expansion of the facility nozzle. The model was moved into the nozzle to escape the shock generated from the nozzle exit, both SETF and the engine could start. The pitot rake experiments (blockage of 2.3%) were done for measuring the core flow in the test section. From the pitot experiments, the core flow was expanded by an under expansion. It means that the core flow in the test section was related with a model blockage. SETF and the engine with a blockage of 33% work normally. From a series of experiments, SETF started with a normal shock efficiency of 58%, regardless of a blockage ratio.

Research to define facility type, project consideration and restriction when conceiving civil-military sharing facilities, by applying the Delphi technique (델파이기법을 활용한 민군간 공용 시설유형 및 고려요소 판단 연구)

  • Gong, Keum Rok;Kang, Han-Seung;Ahn, Jin-Ho;Park, Young Jun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • When developing projects to build facilities to be shared by both military bases and surrounding communities, strategies are needed to achieve two objectives: 1) minimize missteps and opposition from local communities in the process of developing and implementing such projects, and 2) promote cost-benefit optimization and user-satisfaction. With aim of promoting co-operation and co-existence between military bases and adjust communities, this research proposes esthetical factors to be considered in conceiving civil-military sharing facilities. It seeks experts' opinions on the development of civil-military sharing facilities, and examines critical factors (economic feasibility, security, and satisfaction, etc.) for project development as well as building types suitable for shared-use between military bases and local residents. It then establishes a method to prioritize facility-type and narrow down design factors (considerations and restrictions) in project development by applying quantitative analysis. The methodological approach of the research employs the Delphi survey method to quantitatively analyze qualitative information drawn from experts' opinions. At the first round of the survey, facility types, items for consideration and restrictions are drawn, and then at the second round of the survey, criticality of each item is analyzed. Finally, it reaches a conclusion on suitability of facility types for civil-military sharing facilities, and selects project considerations and restrictions when developing this kind of project.

Construction and Start-up Test of Hot-firing Test Facility for KSLV-II Combustion Chamber (한국형발사체 연소기 연소시험설비의 구축 및 시운전)

  • Lee, Kwang-Jin;Yi, Seung Jae;Seo, Daeban;Hwang, Chang Hwan;Woo, Seongphil;Im, Ji-Hyuk;Jeon, Junsu;So, Younseok;Kim, Chae-Hyoung;Kim, Sunghyuk;Kim, Seung-Han;Cho, Namkyung;Han, Yeoung Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • This paper covers the result of construction and start-up tests of the KSLV(Korea Space Launch Vehicle)-II combustion chamber hot-firing test facility. This facility was constructed from 2012 to 2014. Start-up test of this facility began in the second half of 2014. Oxidizer cold flow test, fuel cold flow test and cooling water cold flow test were carried out as start-up test. Afterward, ignition test of combustion chamber was accomplished. The result of ignition test is applied to set up start-up sequence of KSLV-II combustion chamber and utilized as base line data for hot-firing test of low and normal design point.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.