• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.035 seconds

National Certified License Tests for the Facility Management of New and Renewable Energy (Photovoltaic Cell) (신재생에너지 (태양광) 설비 국가 공인 자격증 시험)

  • Jo, Min-Jung;Hwang, Un-Jei;Park, Rei-Hyan;Jo, Dong-Hyun;Kim, Jong-Do;Park, Eun-Hye;Kang, Kwang-Sun
    • Current Photovoltaic Research
    • /
    • v.1 no.2
    • /
    • pp.126-139
    • /
    • 2013
  • New national certified license tests for the facility management of new and renewable energy is given from this year. There are three national certified licenses including craftsman, industrial engineer and engineer. The subjects for the craftsman are photovoltaic facility for written exam and practical business of photovoltaic facility for writing exam. The subjects for the industrial engineer are theory, construction, management and law of the photovoltaic system for written exam and practical business of photovoltaic system for writing exam. The subjects for the engineer add one more subject compared with the industrial engineer, such as design of photovoltaic system. The first tests were given in september 28 in this year. The tests will be given three in 2014.

Layout Criteria of an Access Mode's on and off Facility at Multiple Transfer Centers (복합환승센터 접근교통수단의 승하차 시설배치기준)

  • Kim, Si-Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.95-101
    • /
    • 2012
  • Layout Criteria are developed for an access mode's on and off facility at multiple transfer centers in this paper. Layout Criteria are location issues between a main mode and access modes in terms of the on and off facility one another. The total distance between them has been suggested to be minimized. In the distance calculation stairs are considered to be more difficult and than open space. On the other hand an escalator and an elevator are treated as easier than open space. Considering the number of people between on and off facility, the weighted average distance is suggested to be a MOE(Measure of effectiveness) for layout criteria at multiple transfer centers. Finally, the layout criteria are applied to the existing Kimpo airport terminal and some improvement ideas are suggested.

The Improvement of the Road Facility Database Creation Using a Mobile GIS (모바일 GIS를 활용한 도로시설물 DB구축의 효율성 향상)

  • Lee, Hyun-Jik;Kim, Hyun-Tae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.4 s.27
    • /
    • pp.53-60
    • /
    • 2003
  • GIS was introduced to spatial information of complex and various facility systematically and scientifically. And, recently, new trend has been spread by Mobile GIS owing to its fast development of information and communication technology. However, these Mobile GIS techniques were introduced in maintenances of various facilities. Due to its mismanagement, the use became insufficient in facilities causing database creation to require realism and mobility. Therefore, in this research to road facility of various facilities, it deduced improving the work process by using a Mobile GIS to analyze work process of the road facility database creation. And, through an experiment, by comparing and analyzing road facilities database creation process by existing method and improving method, could improvement of road facility database creation using a Mobile GIS.

  • PDF

INTEGRAL EFFECT TESTS IN THE PKL FACILITY WITH INTERNATIONAL PARTICIPATION

  • Umminger, Klaus;Mull, Thomas;Brand, Bernhard
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.765-774
    • /
    • 2009
  • For over 30 years, investigations of the thermohydraulic behavior of pressurized-water reactors under accident conditions have been carried out in the PKL test facility at AREVA NP in Erlangen, Germany. The PKL facility models the entire primary side and significant parts of the secondary side of a of pressurized water reactor at a height scale of 1:1. Volumes, power ratings and mass flows are scaled with a ratio of 1:145. The experimental facility consists of four primary loops with circulation pumps and steam generators (SGs) arranged symmetrically around the reactor pressure vessel (RPV). The investigations carried out encompass a very broad spectrum from accident scenario simulations with large, medium, and small breaks, over the investigation of shutdown procedures after a wide variety of accidents, to the systematic investigation of complex thermohydraulic phenomena. The PKL tests began in the mid 1970s with the support of the German Research Ministry. Since the mid 1980s, the project has also been significantly supported by the German PWR operators. Since 2001, 25 partner organizations from 15 countries have taken part in the PKL investigations with the support and mediation of the OECD/ NEA (Nuclear Energy Agency). After an overview of PKL history and a short description of the facility, this paper focuses on the investigations carried out since the beginning of the international cooperation, and shows, by means of some examples, what insights can be derived from the tests.

The Evaluation of Service Employees' Sanitary Management in Hotels (특급 호텔 레스토랑 서비스 제공자의 위생 관리 평가)

  • Yoo, Yang-Ja;Lee, Joung-Ki;Choi, Young-Sim
    • Korean journal of food and cookery science
    • /
    • v.22 no.5 s.95
    • /
    • pp.565-572
    • /
    • 2006
  • The purpose of this study was to evaluate the sanitary management of hotel employees in Seoul. The results were summarized as follows : The total mean of sanitary management perception by factor was 3.91${\pm}$0.62, in which personal sanitation, property management, environment and facility factors were, in order, 3.99${\pm}$0.82, 3.91${\pm}$0.75, 3.90${\pm}$0.86 and 3.85${\pm}$0.82, respectively. This study showed that there was a significant difference in the perception of sanitary management among environment, facility and property management by age based on general characteristics. While there were no differences by hiring type, there was a significant difference among environment, facility and property management with personal sanitation factor according to the employee’s career path. There was also a significant difference between property management and personal sanitation factor according to hotel management style. In addition, a significant difference was observed among environment facility and property management with personal sanitation factor according to work place. In conclusion, it is imperative to continue educational programs for sanitary management by career, work place and management style in order to improve sanitary management of hotel employees’.

A Study on The Construction of Cloud BIM-based Medical Facility Design Support System (클라우드 BIM 기반 의료시설 설계지원 시스템 구축에 관한 연구)

  • Jung, Sung-Ho;Lee, Byung-Soo;Choi, Yoon-Ki
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.6
    • /
    • pp.39-46
    • /
    • 2019
  • In the 21st century, medical facility projects are required to operate appropriate digital technologies as the development of technology and the interests of various participants become more complex. In order for architects to successfully lead negotiations among various stakeholder groups, it is necessary to plan for effective communication through appropriate design reflecting their opinions and coordination of conflicts. For this purpose, building information modeling (BIM), which is a method of designing based on knowledge information related to medical facilities in the building database, can respond to change of order promptly and minimizes the occurrence of design errors can do. Recently, BIM technology and cloud computing technology in ICT have been combined and research on cloud BIM has been actively carried out. The use of cloud computing technology in BIM-based healthcare facility projects can effectively support decision making among project participants and has the advantage of sharing and collaborating on various forms of information generated during the design process, regardless of location and time. Therefore, the purpose of this study is to build of system that can support the design of medical facility using cloud computing technology in BIM.

Analysis methodology of local damage to dry storage facility structure subjected to aircraft engine crash

  • Almomani, Belal;Kim, Tae-Yong;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1394-1405
    • /
    • 2022
  • The importance of ensuring the inherent safety and security has been more emphasized in recent years to demonstrate the integrity of nuclear facilities under external human-induced events (e.g. aircraft crashes). This work suggests a simulation methodology to effectively evaluate the impact of a commercial aircraft engine onto a dry storage facility. A full-scale engine model was developed and verified by Riera force-time history analysis. A reinforced concrete (RC) structure of a dry storage facility was also developed and material behavior of concrete was incorporated using three constitutive models namely: Continuous Surface Cap, Winfrith, and Karagozian & Case for comparison. Strain-based erosion limits for concrete were suitably defined and the local responses were then compared and analyzed with empirical formulas according to variations in impact velocity. The proposed methodology reasonably predicted such local damage modes of RC structure from the engine missile, and the analysis results agreed well with the calculations of empirical formulas. This research is expected to be helpful in reviewing the dry storage facility design and in the probabilistic risk assessment considering diverse impact scenarios.

Design and fabrication of beam dumps at the µSR facility of RAON for high-energy proton absorption

  • Jae Chang Kim;Jae Young Jeong;Kihong Pak;Yong Hyun Kim;Junesic Park;Ju Hahn Lee;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3692-3699
    • /
    • 2023
  • The Rare isotope Accelerator complex for ON-line experiments in Korea houses several accelerator complexes. Among them, the µSR facility will be initially equipped with a 600 MeV and 100 kW proton beam to generate surface muons, and will be upgraded to 400 kW with the same energy. Accelerated proton beams lose approximately 20% of the power at the target, and the remaining power is concentrated in the beam direction. Therefore, to ensure safe operation of the facility, concentrated protons must be distributed and absorbed at the beam dump. Additionally, effective dose levels must be lower than the legal standard, and the beam dumps used at 100 kW should be reused at 400 kW to minimize the generation of radioactive waste. In this study, we introduce a tailored method for designing beam dumps based on the characteristics of the µSR facility. To optimize the geometry, the absorbed power and effective dose were calculated using the MCNP6 code. The temperature and stress were determined using the ANSYS Mechanical code. Thus, the beam dump design consists of six structures when operated at 100 kW, and a 400 kW beam dump consisting of 24 structures was developed by reusing the 100 kW beam dump.

Health Risk Assessment of Occupants in the Small-Scale Public Facilites for Aldehydes and VOCs (일부 미적용 다중이용시설의 실내 공기 중 알데히드류 및 휘발성유기화합물 노출로 인한 건강위해성 평가)

  • Yang, Ji-Yeon; Kim, Ho-Hyun;Shin, Dong-Chun;Kim, Yoon-Shin;Sohn, Jong-Ryeul;Lim, Jun-Hwan;Lim, Young-Wook
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.45-56
    • /
    • 2008
  • This study was to assess the lifetime cancer and non-cancer risk of exposure of worker and user at public facilities in Korea to volatile organic compounds (VOCs). We measured the concentrations of two aldehydes and five VOCs in indoor air at 424 public buildings that 8 kinds of public facilities (70 movie theaters, 86 offices, 86 restaurants, 70 academies, 22 auditoriums, 30 PC-rooms, 30 singing-rooms and 30 bars) all over the country. There were estimated the human exposure dose and risks with averages of the using-time and frequency for facility users and office workers, respectively. Carcinogens (formaldehyde, acetaldehyde, and benzene) were estimated the lifetime excess cancer risks (ECRs). non-carcinogens (toluene, ethylbenzene, xylene, and styrene) were estimated the hazard quotients (HQs). The average ECRs of formaldehyde and benzene for facility worker and user were $1{\times}10^{-3}{\sim}1{\times}10^{-4}\;and\;1{\times}10^{-4}{\sim}1{\times}10^{-5}$ level, respectively, in all facilities. HQs of four non-carcinogens did not exceed 1.0 for all subjects in all facilities. The estimated ECRs for restaurant and auditorium were the highest, and the PC-room and bar were the next higher facilities. Furthermore, people in a smoking facility had the highest cancer risk. Higher ECRs of formaldehyde and benzene were observed in indoor smoking facilities such as restaurant and auditorium. Higher HQs of toluene and xylene were observed at the restaurant and office building.

An Analysis on the Appropriation of Chemical Accident Evacuation Facility Using GIS - focused on Ulsan metropolitan city - (GIS 기법을 활용한 화학사고 대피시설의 적정성 분석 - 울산광역시를 대상으로 -)

  • SONG, Bong-Geun;LEE, Tae-Wook;KIM, Hyun-Ju;KIM, Tai-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2018
  • The purpose of this study is to minimize damage of chemical accidents through the appropriation analysis of evacuation facility position focused on Ulsan metropolitan city. For analysis, informations such as pollutant release and transfer registers(PRTR), population census, and evacuation facilities were used. After then, damage assessment of chemical accidents, accessibility and appropriation of evacuation facilities were analyzed. Damage of chemical accidents is high in around 5km of industrial complex there is dense of chemical facility and population. Evacuation facilities were mainly situated in hazard area of chemical accidents, but accessibility of evacuation facilities was vulnerable in chemical plant neighborhood. Therefore, safety check of deteriorated plants is important for prevention of chemical accidents. Also, effective evacuation plan considering capacity and scale of evacuation facilities will be established.