• Title/Summary/Keyword: Research Equipment

Search Result 5,834, Processing Time 0.032 seconds

Analysis of Huawei's PCT Patent Applications (화웨이의 PCT 특허 출원 동향분석)

  • Kim, Marco JinHwan;Han, Yoo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2507-2517
    • /
    • 2015
  • In this research, we aim to analyze the trend of Huawei's PCT patent applications. As a result of analyzing Huawei's PCT patents by dividing temporal spans into three periods - the early 2000s, the late 2000s, and the early 2010s -, the following characteristics have been observed. First, the number of PCT patent applications has conspicuously increased from the early 2000s to the late 2000s and this trend has continued during the early 2010s. Second, in terms of a core technological field, whereas Huawei focused on the development of technologies in the 'H04L: transmission of digital information' sector during the early/late 2000s, it changed this field to the 'H04W: wireless communication networks' sector during the early 2010s. Lastly, in the case of the patent maps, it was found that while general communications technologies, as expressed with such keywords as 'user' and 'network,' were actively developed during the early/late 2000s, mobile phone-related technologies grasped this leading position, as shown with the keywords including 'user equipment,' 'base station,' and 'MME,' during the early 2010s. It was also noticeable that Huawei filed LTE-related patent applications more actively than Apple and Samsung Electronics, which implies that it will presumably pioneer the global market more aggressively than its competitors in the future.

A study on measurement of the pollution levels and disinfection of medical radiation shielding for lead apron (의료방사선 차폐용 납 가운의 오염도 측정 및 소독에 관한 연구)

  • Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.490-497
    • /
    • 2016
  • This study compared and analyzed the pollution levels of radiation shielding aprons and ways to sterilize them using 30 lead aprons. After collecting samples from the center of the lead apron, where contact is most frequent, experiments were conducted employing Coagula and Latex methods. Using the culture medium where bacteria grew, measurements of the pathogen count and identification were performed. The greatest number of pathogens were $7.16{\pm}10$, which were detected on the lead apron from general X-ray room #2, but there was no significant difference according to the facilities (p > 0.05). Compared to how many pathogens remained between using the disinfectant ethanol and tissue, the pathogens decreased by $0.01{\pm}0.4$ (p < 0.05) after using disinfectant ethanol and by $0.87{\pm}1.7$(p < 0.05) after using disinfectant tissue. The Pearson correlation test revealed a significant correlation (-0.296, p < 0.05) between them. According to this research, there were pathogens on the lead aprons and the number of pathogens was determined by statistical analysis. It is expected that the rate of radiology technologists, patients, and medical equipment infected by pathogens will be reduced by the proper use of sterilization with a disinfectant ethanol.

Analysis of Trench Slope Stability in Permafrost Regions According to the Equipment Load (동토 파이프라인 매설공사 시 장비하중에 의한 트렌치 안전성 분석)

  • Kim, Jong-Uk;Kim, Jung-Joo;Lee, Jae-Hyuk;Jafri, Turab H.;Yoo, Han-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.17-25
    • /
    • 2017
  • Recently, the need of alternate energy resources is increasing due to the global warming issue. The natural gas buried in the extremely cold regions of Alaska and Siberia is of much interest these days. However, the construction standards are needed to be used in extremely cold regions. Particularly, more research work need to be carried out on the trench stability so that the safety of the workers is ensured and the damage to the construction machinery can also be reduced resulting in smaller construction period. In this study, the process for lowering of the pipelines of 30 and 40 in. diameters in the ground conditions (silt and peat) of Yakutsk, Russia was analyzed. The slopes of the ground surface were considered as $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$ to be excavated in summer and winter. The analysis results show that the weight of pipelayer affects the trench stability. Numerical analysis was performed by considering the types of pipelayers, distance between the trench and pipelayer, and the distance between the pipelayers placed longitudinally along the trench. The results show that as the distance between the pipelayer and the trench decreases, the factor of safety of the slope decreases with an increase in the slope of the ground surface. When the slope of the ground surface was $20^{\circ}$, the breakout surface was anticipated to continue from the pipelayer to the trench boundary. In winter season, stability problem of the trench was not observed when the slope of the ground surface was less than $20^{\circ}$.

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Design of Communication Board for Communication Network of Nuclear Safety Class Control Equipment (원자력 안전등급 제어기기의 통신망을 위한 통신보드 설계)

  • Lee, Dongil;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.185-191
    • /
    • 2015
  • This paper suggest the safety class communication board in order to design the safety network of the nuclear safety class controller. The reactor protection system use the digitized networks because from analog system to digital system. The communication board shall be provided to pass the required performance and test of the safety class in the digital network used in the nuclear safety class. Communication protocol is composed of physical layer(PHY), data link layer(MAC: Medium Access Control), the application layer in the OSI 7 layer only. The data link layer data package for the cyber security has changed. CRC32 were used for data quality and the using one way communication, not requests and not responses for receiving data, does not affect the nuclear safety system. It has been designed in accordance with requirements, design, verification and procedure for the approving the nuclear safety class. For hardware verification such as electromagnetic test, aging test, inspection, burn-in test, seismic test and environmental test in was performed. FPGA firmware to verify compliance with the life-cycle of IEEE 1074 was performed by the component testing and integration testing.

A study to improve the existing rumble-strip (기존 노면요철 포장 개선 연구)

  • Ryu, Sung-Woo;Lim, Kwan;Park, Kwon-Je;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.177-186
    • /
    • 2009
  • Rumble strip was introduced in highway pavement for driver's safety in Korea on 2000. With proving its effectiveness, total length of highway with rumble strip has increased. This research team suggested a modified form of the existing rumble strip, which was placed on new concrete pavement during construction. The modified construction equipment was applied on test section at PyungTeak-Eumsung highway with some performance experiments. Through the equation of stopping sight distance proposed AASHTO, the modified form is safer than the existing one due to 0.65m of extra width. The indoor noise test showed that the modified form $3.5{\sim}9dB(A)$ noisier than the main pavement, which wasn't applied by rumble method. Therefore, it was one of alternatives to prevent sleeping. The modified form made the frequency effected on man's eye. There were no differences of the noise and vibration between modified form and existing one. However, that driver who participated on operating test on that section felt that the former was safer than the latter. It can be concluded that modified form can be applied to the new concrete pavement, that will decrease traffic accident.

  • PDF

The Study on Choice Standard and Operation Method on Zone 30 in the Outskirts Street of Residential Area (주거지 주변가로 Zone 30 구역 선정기준 및 운영방안 연구)

  • Sim, Gwan-Bo;Go, Myeong-Su;Jo, Seong-Geun
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.39-49
    • /
    • 2009
  • This research analyzes current pedestrian's safety zone choice standard problem and described about correct standard re-thesis at real. About problem of pedestrian traffic accidents to specific item statistical data to basis ramification of pedestrian traffic accidents, occurrence type of accident, action type etc. synthetically analyze and mark pedestrian's safety zone by countermeasure for decrease of pedestrian traffic accidents and utilize operating domestic outer garment reward and drew domestic Zone30 zone choice standard. Also, because analyzing effect that traffic discharge and speed through on-the-spot probe get in pedestrian thinking, presented quantitative standard, and analyze accident special quality of back pedestrian traffic accidents occurrence number of item and so on do accident type beside quantitative standard, road function, accident latitude and present standard. Specially, take advantage of statistical data of traffic accidents and put emphasis in pedestrian safety. Also, because establishment standard about safety facility establishment of Zone30 zone and systematic thesis of operation way do not consist, standard guide of consistency it is no and does equipment that is established in Zone30 zone because confusion happens by each local unit presented establishment and operation way, and present Zone30 zone.

Sectoral Patterns of Technological Innovation in Korean Manufacturing Sector (한국 제조업의 산업별 기술혁신패턴 분석)

  • Hong, Jang-Pyo;Kim, Eun-Young
    • Journal of Technology Innovation
    • /
    • v.17 no.2
    • /
    • pp.25-53
    • /
    • 2009
  • The purpose of this paper is to analysis sectoral patterns of technological innovation in Korean manufacturing sector. Pavitt(1984) put forward a well-known taxonomy that industries three groups of industries characterized by markedly different innovative modes, namely science-based, production-intensive and supplier-dominated industries. Using Pavitt's taxonomy as a framework, we try to explain similarities and differences among sectors in the sources and impact of innovations. Based on a sample of 2,371 firms in manufacturing industry, this paper investigated its relevance to explain the sources and directions of innovative activities in Korean industries. Empirical study shows that in supplier dominated firms most process innovations come from suppliers of equipment and materials. In science-based firms product innovation is produced internally, based on the rapid development of the underlying sciences in the universities and research institutes. It also shows that production-intensive firms have a positive association between innovativeness and customer collaboration. This explanation has implications for our understanding of the sources and directions of technical changes, the formation of technological advantages at the level of both region and country.

  • PDF

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.