• Title/Summary/Keyword: Research Efficiency

Search Result 17,332, Processing Time 0.047 seconds

Comparison of Anaerobic Digestion Efficiency with Different Temperature of Food Wastes (음식물류폐기물의 성상별 온도변화에 따른 혐기성소화 효율 비교 연구)

  • Hwang, Kwanghyun;Kim, Dongik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.332-339
    • /
    • 2019
  • A comparative study on the anaerobic digestion efficiency according to the temperature change was conducted considering the characteristics of domestic food wastes with high water content of about 80 % or more. The substrate was tested for anaerobic digestion efficiency in two substrates, a liquid component separated naturally from food waste and food waste itself. In the anaerobic digestion experiments, the digestion efficiency was the highest at $55^{\circ}C$ (thermophilic temperature). However, the digestion efficiency at $45^{\circ}C$(middle high temperature) was lower than that at $35^{\circ}C$(mesophilic temperature). The comparison of general food wastes anaerobic digestion requiring 30 days of hydraulic retention time to the liquid component indicated a stable digestion efficiency even after 15 days of hydraulic retention time.In the experiments conducted on food waste, the digestion efficiency at $55^{\circ}C$ was higher than that at $35^{\circ}C$. When the food waste, especially the liquid component originating from food waste, is treated by anaerobic digestion method, the mesophilic temperature and thermophilic temperature conditions are more favorable in the digestion efficiency than the middle high temperature ($45^{\circ}C$). However, when applying thermophilic or mesophilic temperature anaerobic digestion process operation in the field, the amount of energy input should be considered.

Efficiency Analysis of Spanish Container Ports Using Undesirable Variables and the Malmquist Index

  • Bernal, Maria Listan;Choi, Young-Seo;Park, Sung-Hoon;Yeo, Gi-Tae
    • Journal of Navigation and Port Research
    • /
    • v.46 no.2
    • /
    • pp.110-120
    • /
    • 2022
  • Spain is Europe's second-largest country with total throughput reaching 16.7 million twenty-foot equivalent units (TEU) by 2020. The purpose of this study was to measure and compare the efficiency of 17 container terminals. As a study method, the DEA-CCR model, undesirable variable, and Malmquist Index (MI) were used for data envelopment analysis (DEA). The study results are as follow: (1) DEA-CCR is used to evaluate basic efficiency. The most efficient terminals are decision-making units DMU 1 (APM Terminals (Algeciras Port)), DMU 2 (Total Terminal International Algeciras (Algeciras Port)) and DMU 5 (Barcelona Europe South Terminal (Barcelona Port)). (2) Undesirable DEA was conducted to suggest inefficiency from the undesirable output. Overall, the efficiency scores were reduced. However, DMU 1, DMU 2, and DMU 5 maintained efficiency scores regardless of the finish factor. (3) Malmquist Index was used to observe technology and efficiency changes dynamically. The changes in TCI affected Spanish container terminals more than the Technical Efficiency Change Index (TECI) in 2018-2019. However, in 2019-2020, the TECI was 2.706, higher than the TCI value, indicating that the change in TECI had more influence on the increase in productivity. This study offers a broader understanding of Spanish container terminals.

A Study on Operational Efficiency Analysis on the Value of Chinese Shipping Companies

  • Cui, Lin-Lin;Choi, Jung-Suk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.3
    • /
    • pp.430-440
    • /
    • 2022
  • Shipping companies are key components of the logistics industry, which is extremely significant in enhancing the country's comprehensive national power and promoting global trade development. In the context of the implementation of the new development pattern strategy in China and the impact of the global novel coronavirus (COVID-19), this paper takes 22 Chinese shipping listed companies as the research object and analyses the operational efficiency of them from 2011 to 2020 based on the Super-SBM DEA Model and Window DEA Model. Factors affecting the efficiency are further analyzed with the Tobit model. The research conclude that the operational efficiency of Chinese shipping companies as a whole shows a steady increase from 2011 to 2020. Although most of them are in a relatively ef ective operation state, fewer are absolutely effective companies. Besides efficiency among companies differs obviously, which indicates the potential of further improvement and promotion. What's more, factors such as current economic development level, enterprise size, human resources quality and enterprise turnover speed have significant positive correlation to the operation efficiency of Chinese shipping listed companies, which is significant to improve the operation efficiency of Chinese shipping companies.

Efficiency enhancement of the organic light-emitting diodes by oxygen plasma treatment of the ITO substrate

  • Hong, J.W.;Oh, D.H.;Kim, C.H.;Kim, G.Y.;Kim, T.W.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.193-197
    • /
    • 2012
  • Oxygen plasma has been treated on the surface of indium-tin-oxide (ITO) to improve the efficiency of the organic light-emitting diodes (OLEDs) device. The plasma treatment was expected to inject the holes effectively due to the control of an ITO work-function and the reduction of surface roughness. To optimize the treatment condition, a surface resistance and morphology of the ITO surface were investigated. The effect on the electrical properties of the OLEDs was evaluated as a function of oxygen plasma powers (0, 200, 250, 300, and 450 W). The electrical properties of the devices were measured in a device structure of ITO/TPD/Alq3/BCP/LiF/Al. It was found the plasma treatment of the ITO surface affects on the efficiency of the device. The efficiency of the device was optimized at the plasma power of 250 W and decreased at higher power than 250 W. The maximum values of luminance, luminous power efficiency, and external quantum efficiency of the plasma treated devices increase by 1.4 times, 1.4 times, and 1.2 times, respectively, compared to those of the non-treated ones.

Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System (석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성)

  • Jeon, Seong-Min;Park, Hyung-Sang;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

Pre-validation of Colony Forming Efficiency Assay for Assessing the Cytotoxicity of Nanomaterials (나노물질의 세포독성 평가법으로 Colony Forming Efficiency Assay에 대한 검증연구)

  • Jo, Eunhye;Lee, Jaewoo;Park, Sun-Young;Kim, Pilje;Choi, Kyunghee;Eom, Igchun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • Objectives: The cytotoxcities of Au, Ag, SWCNT, $SiO_2$, and ZnO nanomaterials were evaluated in order to assess their potential toxicological effects in in vitro cell models using colony forming efficiency (CFE) assay. Methods: The CFE assay of the test materials was carried out on Hep G2 cells. The size distribution of nanomaterials was studied by transmission electron microscopy (TEM). Changes in cell viability after treatment with a toxicant will result in a decreased number of colonies formed in comparison to solvent. Results: The TEM images show that all the particles except SWCNT and ZnO can be considered approximately spherical. The gold and $SiO_2$ nanoparticles show no response (no toxicity) in concentration response experiments. A statistically significant toxic effect was found in Hep G2 cells treated with Ag, SWCNT and ZnO nanomaterials. Conclusion: In this study, we considered CFE assay to be a promising test for screening studies for cytotoxicity with physicochemical analysis.

The Operation Characteristics of Domestic 1kW Gas Fueled Internal Combustion Engine Cogeneration System (1kW급 가스엔진 열병합발전시스템 성능특성에 관한 연구)

  • Choi, Jae-Joon;Park, Byung-Sik;Jung, Dae-Heon;Im, Yong-Hoon;Choi, Young-Ho;Song, Dae-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.321-324
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and recently, the household cogeneration system has been the center object of attention because of the loss of power transmission and the reasonable energy consumption relative to the household (condensing) boiler producing heat only. A tiny, 1kW of electrical output, gas fueled internal combustion engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. With the emission characteristics, the cogeneration system was analyzed. It was showed the gas engine cogeneration system produced the lowest NOx level compared any other cogeneration system due to the three-way catalyst.

  • PDF

Development of decontamination equipment to remove hot particulates contaminated in hot cell at KAERI

  • Kim Gye-Nam;Narayan M.;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.258-268
    • /
    • 2005
  • A new approach has been adopted to remove the hot particulates from nuclear facilities, KAERI, South Korea, by using the new compact cyclone train, made of steel ness steel, with optional vortex finder length. Flow rate results showed a dramatic change in removal efficiency, performance was changed with the change of exit tube length. The 15 m/s flow rate was found suitable one for new equipment with the 49 mm optimum exit tube length for 76 mm cyclone body diameter. Results shows the removal efficiency for $1\;{\mu}m$ was more than $65\%$ and for $10\;{\mu}m$ was seen ${\~}97\%$. Over 15 m/s flow rate, was not shown much different in removal efficiency. The removal efficiency increased with the flow rate, and pressure drop. Cut size diameter decrease with the inlet flow rate. Cut size diameter found lowest with 49 mm exit tube length and 15 m/s flow rate. For filters the performance decreased with the inlet velocity increased.

  • PDF

A Characteristic Analysis on the Thermal Performance of the Dish Type Solar Concentrating System (Dish형 태양열 집광시스템 실증연구를 위한 집열성능 특성 분석)

  • Kang, Myeong-Cheol;Kang, Yong-Heack;Yoon, Hwan-Ki;Yoo, Seong-Yeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • The dish type solar thermal concentrating system can collect the solar energy above $800^{\circ}C$. It has a concentration ratio of 800 and total reflector area of $49m^2$. To operate solar receivers at high temperature, the optimum aperture size is obtained from a comparison between maximizing absorbed energy and minimizing thermal losses. The system efficiency is defined as the absorbed energy by working fluid in receiver divided by the energy coming from the concentrator. We find that system efficiency is stable in case of flow rate of above 6lpm. The system efficiency are 64.9% and 65.7% in flow rate of 6lpm and 8lpm, respectively. The thermal performance showed that the maximum efficiency and the factor of thermal loss in flow rate of 8lpm are 68% and 0.0508.

Loss and Efficiency Dependence of a 6.78 MHz, 100 W, 30 cm Distance Wireless Power Transfer System on Cable Types (6.78 MHz, 100 W, 30 cm 거리 무선 전력 전송 시스템의 전선별 손실 및 효율 비교)

  • Lee, Seung-Hwan;Lee, Byung-Song;Jung, Shin-Myung;Park, Chan-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1651-1657
    • /
    • 2015
  • In MHz operating wireless power transfer systems, skin- and proximity-effect losses in the transmitter and the receiver coils dominate the coil-to-coil efficiency of the system. A Litz-wire was regarded as a common solution for minimizing such Ohmic losses in high frequencies. In this paper, equivalent series resistances of 12 different cables including Litz-wire and copper tubing have been calculated and measured for a 6.78 MHz, 100W, 30 cm wireless power transfer system. It has been shown that the copper tubing has lower resistances compared to the Litz-wire in that frequency and a wireless power transfer system with the copper tubing was able to achieve much higher efficiency than a system using the Litz-wire. Calculations of the resistances and efficiencies were accomplished with analytical equations and those calculations were evaluated by experimental results.