• 제목/요약/키워드: Required performance

검색결과 8,753건 처리시간 0.041초

스윙형 역지밸브 성능 평가 방법 (Performance Evaluation Method of a Swing Check Valve)

  • 김양석;이도환;김대웅;박성근;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF

Neutronic investigation of waste transmutation option without partitioning and transmutation in a fusion-fission hybrid system

  • Hong, Seong Hee;Kim, Myung Hyun
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1060-1067
    • /
    • 2018
  • A feasibility of reusing option of spent nuclear fuel in a fusion-fission hybrid system without partitioning was checked as an alternative option of pyro-processing with critical reactor system. Neutronic study was performed with MCNP 6.1 for this option, direct reuse of spent PWR fuel (DRUP). Various options with DRUP fuel were compared with the reference design concept; transmutation purpose blanket with (U-TRU)Zr fuel loading connected with pyro-processing. Performance parameters to be compared are transmutation performance of transuranic (TRU) nuclides, required fusion power and tritium breeding ratio (TBR). When blanket part is loaded only with DRUP, initial $k_{eff}$ level becomes too low to maintain a practical subcritical system, increasing the required fusion power. In this case, production rate of TRU nuclides exceeds the incineration rate. Design optimization is done for combining DRUP fuel with (U-TRU)Zr fuel. Reactivity swing is reduced to about 2447 pcm through fissile breeding compared to (U-TRU)Zr fuel option. Therefore, a required fusion power is reduced and tritium breeding performance is improved. However, transmutation performance with TRU nuclides especially $^{241}Am$ is degraded because of softening effect of spectrum. It is known that partitioning and transmutation should be accompanied with fusion-fission hybrid system for the effective transmutation of TRU.

간호조직내 인사고과제도운영에 관한 고찰 (A Study on the Management of Performance Rating System in Nursing Organization)

  • 하나선
    • 대한간호
    • /
    • 제31권5호
    • /
    • pp.53-64
    • /
    • 1992
  • A nurse is give much weight in the professions of hospital.The effective achievement of a goal of hospital organization needs to get nurses to contribute the structure positively through the rational personnel management of the nurses.The operation of performance rating system is necessary to improve because the nurses hold negative opinions about the resonable management of that system in most Korean hospitals.Therefore, the prupose of this research was to suggest an efficient method to solve the problem in connection with the management of nurses performance rating system.The results of the study are summarized as follows.1. As the performance rating implies the evaluation of employee's functional accomplishment and ability, and essential condition of the job was surveyed according to the job analysis of nursing activities and nurse position.That is to say, Nusrses' performances and capability is estimated in comparision with the condition of the job. 2. It is required adequacy for evaluation factors in performance rating.That is, $\circled1$ as for those who work in psychiatry or newborn baby room they should be appraied in terms of different factors from those applicable to whom work in a general staffs. $\circled2$ Evaluation factors should be concrete so that the quality and quantity of work and the potential ability of them can be correctly appraised. 3. In order to realize the object of perfamance rating system, the training on chief nurses are quite important. Also, careful practices and continuous supplementary training are required before the system is introduced.First of all, the appropriate evaluation can be mad by continuing to record the rating objects every day for the purpose of obtaining the objectivity of rating. 4. In course of transfering of the position and training, the induction of self-rating system and presentation of self-description is required to supplement functionally the performance rating system. 5. For the efficiency of nurses' performance rating system, the results of performance rating system must be reflected in promotion, allocation and training course, which makes the nurses have the motives and the organization accomplish the goal of modern nursing through its activation.

  • PDF

영상의 국부적 성질을 이용한 가변 크기 블록 정합 알고리즘 (A Variable Size Block Matching Algorithm Using Local Characteristics of Images)

  • 김진태;최종수;박래홍
    • 전자공학회논문지B
    • /
    • 제29B권7호
    • /
    • pp.62-69
    • /
    • 1992
  • The conventional BMA is performed with the fixed block size. For better performance at low bitrate, the block size is required to be large in relatively stationary area, while small in moving area. Thus, in this paper, a video coding technique using variable block size model is proposed. It decides the block size based on the degree of local motion defined by the local mean and variance of blocks. Computer simulation shows that the proposed method gives comparable performance to the conventional one with less bits required for motion vector coding.

  • PDF

주택성능등급표시제도의 개선을 위한 인정 단지의 사업계획변경 현황에 대한 실태조사 연구 (A Study on the Business Plan Changes of Housing Complex evaluated by the "Housing Performance Grading Indication System")

  • 이성옥;배철학
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.43-51
    • /
    • 2011
  • This study aims to analyze on the change status in the project plan of the housing complex as evaluated through the Housing Performance Grading Indication System. This a a system for assessing quantitatively the comprehensive, unified performance of housing by an objective standard from the design stage since January 9, 2006. As housing is a composite with various performances, it is required necessary to objectively assess the various performances from the design stage for building better housing. Thus, this study analyzed the change status and objectively described objectively it centering on the construction and structure drawings for 12 items posted in the Facility Management System_(FMS) out of examples recognized by 2011 since the implementation of the system. The changes were analyzed though observing each performance item-specific characteristics and confirming the books approved for use. In various parts, such as the site area, landscape plan, plane plan for unit, supplementary welfare facility plan, finishing materials, window size and location, the project plan was changed. These changes may result in a grading change in of the performance items of the system. This study purpose is for it to be used as a basic resource required for future system development by supplementing the limitation of the design phase and then through playing a basic role for the assessment after completion.

곡물냉각기의 성능해석을 위한 시뮬레이션 (Simulation for Performance Analysis of a Grain Cooler)

  • 박진호;정종훈
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.449-460
    • /
    • 2001
  • This study was carried out to develop a simulation model with EES(Engineering equation solver) for analyzing the performance of a grain cooler. In order to validate the developed simulation model, several main factors which have affected on the performance of the gain cooler were investigated through experiments. A simulation model was developed in the standard vapor compression cycle, and then this model was modified considering irreversibe factors so that the developed alternate model could predict the actual cycle of a grain cooler. The compressor efficiency in vapor compression cycle considering irreversibility much affected on the coefficient of performance(COP). The COP in the standard vapor compression cycle model was greatly as high as about 6.50, but the COP in an alternative model considering irreversibility was as low as about 3.27. As a result of comparison between the actual cycle and the vapor compression cycle considering irreversibility, the difference of pressure at compressor outlet(inlet) was a little by about 48kPa (8.8kPa), the temperatures of refrigerant at main parts of the grain cooler were similar. and the temperature of chilled air was about 8$\^{C}$ in both. The model considering irreversibility could predict performance of the grain cooler. The theoretical period required to chill grain of 1,383kg from the initial temperature 24$\^{C}$ to below 11$\^{C}$ was about 55 hours 30 minutes, and the actual period required in a grain bin was about 58 hours. The difference between the predicted and an actual period was about 2 hours 30 minutes. The cooling performance predicted by the developed model could well estimate the cooling period required to chill the grain.

  • PDF

BIM기반 공동주택 결로 성능평가를 위한 프로세스 개선방안에 관한 기초연구 (A preliminary Study on Process Improvement for BIM based Condensation Performance Evaluation of Apartment Housings)

  • 홍주영;김대길;이명도;김대원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.245-246
    • /
    • 2016
  • The condensation performance evaluation is required for improved living environment of apartment housings. In the current condensation performance evaluation process, high demand of manual works and repetitive process cause unexpected risks due to uncertainty and inefficiency by applying 2D CAD drawings in simulation tool. Furthermore, the evaluation requires taking in action responding to the expanding use of BIM. In this study, the analysis of current evaluation process and required functions for the process improvement based on BIM modeling were deducted from interviews with experts. It is expected that the results of this study can be employed to develop of process automation module for condensation simulation evaluation.

  • PDF

모델기준 PID 유전 제어기를 이용한 DC 서보 전동기 제어 (DC Servo Motor Control using Model Reference PID Genetic Controller)

  • 손재현;조양행;김제홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.141-145
    • /
    • 2001
  • In this paper, model reference PID genetic controller was proposed in order to overcome the difficulty of reflecting control performance required in the overall control system and defects of the adaptation performance in the PID genetic controller. The proposed controller comprised Inner feedback loop consisting of the PID controller and plant, and outer loop consisting of an genetic algorithm which was designed for tuning a parameter of the controller. A reference model was used for design criteria of a PID controller which characterizes and quantizes the control performance required in the overall control system. Tuning parameter of the controller is performed by the genetic algorithm. The performance of proposed algorithm was verified through experiment for the DC servo motor.

  • PDF

흡음형 방음벽의 성능향상에 관한 연구 (A Study on Performance Improvement of Sound Absorbing Noise Barrier)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.849-854
    • /
    • 2001
  • A study on performance of the sound absorbing noise barrier is presented. Noise barrier of sound absorbing type is composed of the front panel, sound absorbing material, and back panel. For allowing sound path, front panel is usually perforated. The performance of the noise barrier is governed by the opening ratio of the perforated panel, sound absorption coefficient of the sound absorbing material. In this study, the effects of the opening ratio, diameter of the hole, thickness of the sound absorbing material are investigated. It is found that the thickness of the sound absorbing material must be at least 50 mm to ensure the required minimum NRC value 0.70, and the opening ratio is greater than 0.2. It is shown that the thickness of the back panel is crucial in providing required STL (Sound Transmission Loss) value. The performance of the developed noise barrier is measured, where its sound absorbing coefficient and sound transmission loss satisfy the criteria.

  • PDF

20℃ 조건에서 초지연제 혼입율 변화에 따른 응결지연 성능 변화 분석 (Analysis of Setting Delay Performance Change of Super Retarding Agent According to the Change of Mixing Rate at 20℃)

  • 임군수;한수환;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.127-128
    • /
    • 2020
  • This research is part of the research for unifying the mass concrete and utilizing the rate of super retarding agent. We analyzed the performance of super retarding agent 20℃ conditions. It was found that there was no deterioration in fluidity and air quality due to the change in the super retarding agent mixing rate. It was found that when super retarding agent was mixed up to 0.5 %, it was delayed for 22.3 hours at 20℃. Therefore in order to ensure the performance required at the site, the super retarding agent mixing rate must be determined by fully considering the situation at the site. In addition it will be analyzed that super retarding agent performance analysis at high temperature will be required in subsequent studies.

  • PDF