• Title/Summary/Keyword: Reproducibility of the results

Search Result 862, Processing Time 0.026 seconds

Echocardiography Core Laboratory Validation of a Novel Vendor-Independent Web-Based Software for the Assessment of Left Ventricular Global Longitudinal Strain

  • Ernest Spitzer;Benjamin Camacho;Blaz Mrevlje;Hans-Jelle Brandendburg;Claire B. Ren
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.135-141
    • /
    • 2023
  • BACKGROUND: Global longitudinal strain (GLS) is an accurate and reproducible parameter of left ventricular (LV) systolic function which has shown meaningful prognostic value. Fast, user-friendly, and accurate tools are required for its widespread implementation. We aim to compare a novel web-based tool with two established algorithms for strain analysis and test its reproducibility. METHODS: Thirty echocardiographic datasets with focused LV acquisitions were analyzed using three different semi-automated endocardial GLS algorithms by two readers. Analyses were repeated by one reader for the purpose of intra-observer variability. CAAS Qardia (Pie Medical Imaging) was compared with 2DCPA and AutoLV (TomTec). RESULTS: Mean GLS values were -15.0 ± 3.5% from Qardia, -15.3 ± 4.0% from 2DCPA, and -15.2 ± 3.8% from AutoLV. Mean GLS between Qardia and 2DCPA were not statistically different (p = 0.359), with a bias of -0.3%, limits of agreement (LOA) of 3.7%, and an intraclass correlation coefficient (ICC) of 0.88. Mean GLS between Qardia and AutoLV were not statistically different (p = 0.637), with a bias of -0.2%, LOA of 3.4%, and an ICC of 0.89. The coefficient of variation (CV) for intra-observer variability was 4.4% for Qardia, 8.4% 2DCPA, and 7.7% AutoLV. The CV for inter-observer variability was 4.5%, 8.1%, and 8.0%, respectively. CONCLUSIONS: In echocardiographic datasets of good image quality analyzed at an independent core laboratory using a standardized annotation method, a novel web-based tool for GLS analysis showed consistent results when compared with two algorithms of an established platform. Moreover, inter- and intra-observer reproducibility results were excellent.

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Yield stress measurements in suspensions: an inter-laboratory study

  • Nguyen, Q. Dzuy;Akroyd, Timothy;Kee, Daniel C. De;Zhu, Lixuan
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.1
    • /
    • pp.15-24
    • /
    • 2006
  • The first international inter-laboratory study, involving six laboratories, has been conducted to examine issues associated with yield stress measurements in suspensions. The initial focus of the project was to evaluate the reliability and reproducibility of several common yield stress measuring techniques employed in different laboratories and with different instruments. Aqueous suspensions of colloidal $TiO_2$ at concentrations of 40-70 wt% solids were used as the test fluids. A wide range of instruments and techniques employing both direct and indirect methods were used to determine the yield stress of the samples prepared according to a prescribed procedure. The results obtained indicated that although variations of results existed among different techniques, direct yield stress measurements using static methods produced more reliable and repeatable results than other methods. Variability of the yield stress measured using different techniques within any laboratory however was less significant than variability of the results among different laboratories. The nature and condition of the test suspensions was identified as the most likely factor responsible for the poor reproducibility of yield stress measurements from different laboratories.

Future Climate Change Impact Assessment of Chungju Dam Inflow Considering Selection of GCMs and Downscaling Technique (GCM 및 상세화 기법 선정을 고려한 충주댐 유입량 기후변화 영향 평가)

  • Kim, Chul Gyum;Park, Jihoon;Cho, Jaepil
    • Journal of Climate Change Research
    • /
    • v.9 no.1
    • /
    • pp.47-58
    • /
    • 2018
  • In this study, we evaluated the uncertainty in the process of selecting GCM and downscaling method for assessing the impact of climate change, and influence of user-centered climate change information on reproducibility of Chungju Dam inflow was analyzed. First, we selected the top 16 GCMs through the evaluation of spatio-temporal reproducibility of 29 raw GCMs using 30-year average of 10-day precipitation without any bias-correction. The climate extreme indices including annual total precipitation and annual maximum 1-day precipitation were selected as the relevant indices to the dam inflow. The Simple Quantile Mapping (SQM) downscaling method was selected through the evaluation of reproducibility of selected indices and spatial correlation among weather stations. SWAT simulation results for the past 30 years period by considering limitations in weather input showed the satisfactory results with monthly model efficiency of 0.92. The error in average dam inflow according to selection of GCMs and downscaling method showed the bests result when 16 GCMs selected raw GCM analysi were used. It was found that selection of downscaling method rather than selection of GCM is more is important in overall uncertainties. The average inflow for the future period increased in all RCP scenarios as time goes on from near-future to far-future periods. Also, it was predicted that the inflow volume will be higher in the RCP 8.5 scenario than in the RCP 4.5 scenario in all future periods. Maximum daily inflow, which is important for flood control, showed a high changing rate more than twice as much as the average inflow amount. It is also important to understand the seasonal fluctuation of the inflow for the dam management purpose. Both average inflow and maximum inflow showed a tendency to increase mainly in July and August during near-future period while average and maximum inflows increased through the whole period of months in both mid-future and far-future periods.

Development of Oil Leakage Stability Evaluation for Composite Aterproofing Methods using Asphalt Mastic and Modified Asphalt Sheet in Concrete Structure (콘크리트 구조물에 사용되는 개량아스팔트 시트와 아스팔트 매스틱을 복합화한 방수공법의 누유안정성 평가방법 개발)

  • Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.19-29
    • /
    • 2019
  • In this study, a revised oil leakage evaluation method for assessing oil leakage stability of asphalt mastics used in upper slabs of below-grade residential parking lots was developed and presented. In order to verify the reliability and reproducibility of leakage results, the parameters the revised evaluation was carried out for three products with actual leakage history, and it was confirmed the leaks could be reproduced whereas the existing methods could not. To quantitatively verify the reproducibility, the filler content of the leaked samples was derived and the maximum filler content was 64% lower than that of the normal sample. The same results was found with the samples from the actual leakage site, thus verifying the reliability of the revised evaluation method.

A new bite block for panoramic radiographs of anterior edentulous patients: A technical report

  • Park, Jong-Woong;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. Materials and Methods: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Results: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conclusion: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

A study of the color reproducibility and color fastness of digital textile printing for nylon sublimation transfer (나일론 승화전사 디지털 프린팅의 컬러 재현성 및 견뢰도에 관한 연구)

  • Choi, Gyung-Me;Kim, Ki-Hoon
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.5
    • /
    • pp.754-763
    • /
    • 2018
  • This study examined the color reproducibility and color fastness of digital textile printing for nylon sublimation transfer. After measuring the temperature and time suited to nylon sublimation transfer, the researchers conducted various tests for comparison and analysis including polyester transfer paper on polyester fabric to check dyeing characteristics, color change, sharpness, and the rubbing fastness of the dyeing samples for nylon sublimation transfer. These tests produced the following results. At $185^{\circ}C$ and $187^{\circ}C$, the sublimation transfer dyeing characteristics of nylon were similar to those of polyester and the researchers even observed superior color development in some colors; at a low temperature of $180^{\circ}C$, the sample that was worked on had the lowest level of color development. The examination of color difference (${\Delta}E$), which compared $L^*a^*b^*$ values, showed that the ${\Delta}E$ value of magenta was 10.34, that of yellow was 24.70, and that of black was 15.28. These results highlight the important role of heat treatment temperature and time on color development in nylon sublimation transfer. Concerning sharpness, the samples subjected to higher temperature heat treatment exhibited fewer color spreading phenomena around lines. Thus, dyeing properties and fastness can be enhanced by elongating time at low temperatures and shortening time at high temperatures; however, considering production time constraints as well as the need to produce industrially marketable quantities, the findings of this study suggest that the heat treatment temperature most suitable for nylon sublimation transfer is $187^{\circ}C$ for a duration of 50 seconds.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Development of Rheoencephalograph(I) (임피던스 방법을 이용한 뇌혈류량 측정기기의 개발( I ))

  • 김덕원;김정래
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.25-32
    • /
    • 1989
  • In this study, Rheoencephalography( REG ) was designed and constructed. Using the cons- tructed instrument cerebral blood flow(CBF) of left and right brain, CBF change by posture, and reproducibility were studied. Followings are important results. Relative CBF could be measured noninvasively and continuously. Since reproducibility of the constructed REG was found to be quite high (4%), the accuracy of the instrument itself was proved. REG can be easily applied for testing the effect of drugs for the patients with cerebral vessel diseases since it is quite sensitive to the relative changes of CBF. Various cerebral diseases can be diagnosed by analyzing the REG waveforms. The area of restricted cerebral blood vessels can be located by arranging the electrode configuration. Comparative studies with the standard techinques of measuring CBF are needed to verify the accuracy of REG. Further studies on optimal electrode configuration and various artifacts are also necessary.

  • PDF