• Title/Summary/Keyword: Reproducibility of the results

Search Result 869, Processing Time 0.027 seconds

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

Reproducibility of non-invasive measurement for left ventricular contractility using gated myocardial SPECT (게이트 심근 SPECT를 이용한 비침습적 심실 수축력 측정방법의 재현성)

  • Kim, Kyeong-Min;Lee, Dong-Soo;Kim, Yu-Kyeong;Cheon, Gi-Jeong;Kim, Seok-Ki;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.152-160
    • /
    • 2001
  • Purpose: We tried to establish the reproducibility of the measurement of maximal elastance (Emax) and to compare the degree of the reproducibility of two estimation methods: single pressure-volume loop method and parameter optimization method. Materials and methods: In 47 patients (42 males and 5 females, $53{\pm}10$ years old) with suspected coronary artery disease (election fraction; 22-68%), gated Tc-99m MIBI myocardial SPECT and arterial tonometry were acquired. In 11 patients among these 47 patients, gated SPECT and tonometry were performed twice consecutively with patients in situ. Emax and void volume (Vo) were estimated using single pressure-volume loop method of Lee and parameter optimization method based on linear approximation of Yoshizawa. Correlation between the consecutive measurements by each method and correlation between the two estimation methods were compared. Results: Reproducibility of Emax (r=0.96) and Vo (r=0.99) by single pressure-volume method was better than the reproducibility of Emax (r=0.89) and Vo (r=0.64) by parameter optimization method. Correlations of Emax and Vo were fair between the two methods. The correlation of Emax (r=0.77) was better than that of Vo (r=0.55). Conclusion: Reproducibility of Emax measurement by single pressure-volume loop method using gated myocardial SPECT and arterial tonometry was excellent. Reproducibility by parameter optimization method was also fair but was less than that achieved by single pressure-volume method.

  • PDF

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.32 no.4
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.

  • PDF

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

A STUDY ON THE DESIGN OF SIMPLE RECORDING DEVICE TO TRACE THE MANDIBULAR MOVEMENTS (하악골운동 추적을 위한 단순기록장치 고안에 관한 연구)

  • Kim, Sang-Soo;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.253-267
    • /
    • 1987
  • The purpose of this study was to improve limitations and disadvantages of the mechanical pantograph and the Visi-Trainer, and to design the reliable and reproducible device mandibular movement tracking device (MMTD) that is more simple, convenient and save the chair time than the mechanical pantograph and Visi-Trainer. MMTD was consist of head frame, horizontal bar, condylar path tracking stylus holders, anterior path tracking stylus holder, two condylar path plastic recording plates, one anterior path plastic recording plate, toggles and open occlusal clutch. To prove the reliability and reproducibility of MMTD, a five adults were selected and mandibular condylar movement was recorded one time by the mechanical pantographic tracing and MMTD. The border movement recording of the mandibular incisor (frontal, sagittal and horizontal) was also recorded by Visi-Trainer and the MMTD. The obtained results were as follows; 1. The condylar movement path (sagittal, horizontal) of the MMTD was not coincidence with that of mechanical pantograph. 2. Measurements of the angulation which established between working and balancing path records by use of the mechanical pantograph and MMTD, there was no significance. 3. In a view of MMTD's reproducibility, there was revealed almost similar recording pattern. 4. The border movement recording of the mandibular incisor by the MMTD and the Visi-Trainer showed almost same reliability and reproducibility. 5. The subjects were able to his original mandibular movements by use of open occlusal clutch in the MMTD.

  • PDF

Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren's Syndrome

  • Qing-Qing Zhou;Wei Zhang;Yu-Sheng Yu;Hong-Yan Li;Liang Wei;Xue-Song Li;Zhen-Zhen He;Hong Zhang
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.455-465
    • /
    • 2022
  • Objective: To compare the reproducibility and performance of quantitative metrics between ZOOMit and conventional intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) in the diagnosis of early- and mid-stage Sjögren's syndrome (SS). Materials and Methods: Twenty-two patients (mean age ± standard deviation, 52.0 ± 10.8 years; male:female, 2:20) with early- or mid-stage SS and 20 healthy controls (46.9 ± 14.6 years; male:female, 7:13) were prospectively enrolled in our study. ZOOMit IVIM and conventional IVIM MRI were performed simultaneously in all individuals using a 3T scanner. Quantitative IVIM parameters - including tissue diffusivity (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) - inter- and intra-observer reproducibility in measuring these parameters, and their ability to distinguish patients with SS from healthy individuals were assessed and compared between ZOOMit IVIM and conventional IVIM methods, appropriately. MR gland nodular grade (MRG) was also examined. Results: Inter- and intra-observer reproducibility was better with ZOOMit imaging than with conventional IVIM imaging (ZOOMit vs. conventional, intraclass correlation coefficient of 0.897-0.941 vs. 0.667-0.782 for inter-observer reproducibility and 0.891-0.968 vs. 0.814-0.853 for intra-observer reproducibility). Significant differences in ZOOMit f, ZOOMit D*, D*, conventional D*, and MRG between patients with SS and healthy individuals (all p < 0.05) were observed. ZOOMit D* outperformed conventional D* in diagnosing early- and mid-stage SS (area under receiver operating curve, 0.867 and 0.658, respectively; p = 0.002). The combination of ZOOMit D*, MRG, and ZOOMit f as a new diagnostic index for SS, increased diagnostic area under the curve to 0.961, which was higher than that of any single parameter (all p < 0.01). Conclusion: Considering its better reproducibility and performance, ZOOMit IVIM may be preferred over conventional IVIM MRI, and may subsequently improve the ability to diagnose early- and mid-stage SS.

Reproducibility of Electromyography Signal Amplitude during Repetitive Dynamic Contraction

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.689-694
    • /
    • 2011
  • Objective: The aim of this study is to evaluate the fluctuation of signal amplitude during repetitive dynamic contraction based on surface electromyography(EMG). Background: The most previous studies were considered isometric muscle contraction and they were difference to smoothing window length by moving average filter. In practical, the human movement is dynamic state. Dynamic EMG signal which indicated as the nonstationary pattern should be analyzed differently compared with the static EMG signal. Method: Ten male subjects participated in this experiment, and EMG signal was recorded by biceps brachii, anterior/posterior deltoid, and upper/lower trapezius muscles. The subject was performed to repetitive right horizontal lifting task during ten cycles. This study was considered three independent variables(muscle, amplitude processing technique, and smoothing window length) as the within-subject experimental design. This study was estimated muscular activation by means of the linear envelope technique(LE). The dependent variable was set coefficient of variation(CV) of LE for each cycle. Results: The ANOVA results showed that the main and interaction effects between the amplitude processing technique and smoothing window length were significant difference. The CV value of peak LE was higher than mean LE. According to increase the smoothing window length, this study shows that the CV trend of peak LE was decreased. However, the CV of mean LE was analyzed constant fluctuation trend regardless of the smoothing window length. Conclusion: Based on these results, we expected that using the mean LE and 300ms window length increased reproducibility and signal noise ratio during repetitive dynamic muscle contraction. Application: These results can be used to provide fundamental information for repetitive dynamic EMG signal processing.

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT (게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Cheon, Gi-Jeong;Kim, Yu-Kyeong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.487-496
    • /
    • 2000
  • Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

  • PDF

A Study on the Present Status of the Quality Evaluation Capability of Domestic Paper Industry -A Case Study for Fine Paper Industry (국내 제지산업의 품질평가 실태연구-백상지업체를 중심으로-)

  • 이학래;윤혜정;김태영;조중연
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.94-100
    • /
    • 2000
  • This study was carried out to understand the present status of the quality evaluation capability of domestic fine paper industry. Six light weight coated papers and one wood containing printing and writing paper with similar basis weights were produced by seven paper companies and their properties were evaluated at four different testing laboratories of domestic fine paper mills. Paper properties including basis weight , thickness , tensile, tear , brightness , opacity, etc were examined , and the repeat ability and reproducibility of the test results were analyzed. Results showed that repeatability of the measurements within the laboratory was satisfactory . Reproducibility of the measurements between laboratories, however, was not satisfactory. This showed that strict implementation of the standard testing methods and periodic calibration of testing equipments should be made to improve quality evaluation capability of domestic fine paper industry.

  • PDF