• 제목/요약/키워드: Reproducibility of the results

검색결과 862건 처리시간 0.029초

맥진기 판독의 신뢰도 및 파형의 재현성 연구 (Study on Reliability of Interpretation and Reproducibility of a Pulse Analyser)

  • 박승찬;이지혜;이혜윤;조민경;김도형;김소연;최준용;한창우;박성하;홍진우;이인;권정남
    • 대한한방내과학회지
    • /
    • 제34권3호
    • /
    • pp.231-239
    • /
    • 2013
  • Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.

장단기유출 양용저유 탱크 모델의 개발에 관한 연구 (II) (Studies on the Development of Storage Tank Model for both Long and Short Terms Runoff (II))

  • 이순혁;박명근
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.51-60
    • /
    • 1991
  • The main objective of this study is to examine the adaptability for the large watershed of the storage tank model which can be applied for the analysis of both long and short terms runoff developed on the basis of hydrologic data for a smaH mountaineous watershed. The results obtained in this study are summarized as follows ; 1. Areal rainfalls of the Dae Chong watershed were calculated by Thiessen method composed of 9 Thiessen networks. 2. Optimal parameters for two types, Model A and Model B of tank models were derived through calibration procedure by standardized Powell method. 3. Monthly simulated flows of Model B are seemed to be closer to the monthly observed than those of Model A during calibration period in the long terms runoff. 4. Relative errors for the simulated flood flows of Model B were apperaed as lower percentage to the observed than those of Model A during calibration period in the short terms runoff. 5. Daily simulated hydrographs of Model B are seemed to be closer to the daily observed than those of Model A during verification period in the long terms runoff. Significance of Model B was highly acknowledged in comparison with Model A in the correlation analysis between annual observed and annual simulated runoff. 6. Reproducibility of simulated flows for Model B is generally seemed to be better than that of Model A during calibration period in the short terms runoff. 7. It can be concluded that reproducibility of Model B is superior to that of Model A in the long and short terms runoff even a large watershed like the result of the small one. 8. It was verified that adaptability for the large watershed of Model B is superior to that of Model A between the two models which were developed by a small watershed characteristics for both long and short terms runoff. 9. Further study for getting a suitable tank model is desirable to be established by the decision, calibration method of initial parameters of tank model and by additional application of another watershed with different watersheds and meterological characteristics.

  • PDF

Can a spontaneous smile invalidate facial identification by photo-anthropometry?

  • Pinto, Paulo Henrique Viana;Rodrigues, Caio Henrique Pinke;Rozatto, Juliana Rodrigues;da Silva, Ana Maria Bettoni Rodrigues;Bruni, Aline Thais;da Silva, Marco Antonio Moreira Rodrigues;da Silva, Ricardo Henrique Alves
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.279-290
    • /
    • 2021
  • Purpose: Using images in the facial image comparison process poses a challenge for forensic experts due to limitations such as the presence of facial expressions. The aims of this study were to analyze how morphometric changes in the face during a spontaneous smile influence the facial image comparison process and to evaluate the reproducibility of measurements obtained by digital stereophotogrammetry in these situations. Materials and Methods: Three examiners used digital stereophotogrammetry to obtain 3-dimensional images of the faces of 10 female participants(aged between 23 and 45 years). Photographs of the participants' faces were captured with their faces at rest (group 1) and with a spontaneous smile (group 2), resulting in a total of 60 3-dimensional images. The digital stereophotogrammetry device obtained the images with a 3.5-ms capture time, which prevented undesirable movements of the participants. Linear measurements between facial landmarks were made, in units of millimeters, and the data were subjected to multivariate and univariate statistical analyses using Pirouette® version 4.5 (InfoMetrix Inc., Woodinville, WA, USA) and Microsoft Excel® (Microsoft Corp., Redmond, WA, USA), respectively. Results: The measurements that most strongly influenced the separation of the groups were related to the labial/buccal region. In general, the data showed low standard deviations, which differed by less than 10% from the measured mean values, demonstrating that the digital stereophotogrammetry technique was reproducible. Conclusion: The impact of spontaneous smiles on the facial image comparison process should be considered, and digital stereophotogrammetry provided good reproducibility.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

다층 지르코니아 블록 종류와 소결방법에 따른 지르코니아 코핑의 파절강도와 색조 비교 (Comparison of fracture strength and color of zirconia copings according to multi-layer zirconia blocks and sintering method)

  • 강재민;김원영;정인성
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.195-201
    • /
    • 2019
  • Purpose: This study was investigated the effect of multilayer zirconia block type and sintering method on fracture strength, micro structure and color of zirconia copings. Methods: Three kinds of multi-layered zirconia blocks were used to identify the effects of the kinds of multi-layered zirconia blocks and sintering methods on fracture strength and color reproducibility of zirconia copings. 60 Zirconia copings were fabricated and fracture strength, micro structure and color reproducibility were compared and evaluated. Results: In all the blocks, the CS group, which refers to the general sintering method had higher fracture strength of zirconia copings than the MS group that refers to the microwave sintering method(MCS/MMS; 2,107.5N/1,930.4N, DCS/DMS; 917.0N/879.1N, UCS/UMS; 2,256.9/2,050.7N). In relation to CIE $L^*$, $a^*$, $b^*$ values of zirconia copings depending on the kinds of multi-layered zirconia blocks and sintering methods, the MS group using the microwave sintering method had lower brightness and chroma than the CS group using the general sintering method. Conclusion: In all the blocks, the CS group(general sintering) had higher fracture strength of zirconia copings than the MS group(microwave sintering). In relation to CIE $L^*$, $a^*$, $b^*$ values of zirconia copings depending on the kinds of multilayered zirconia blocks and sintering methods, the MS group using the microwave sintering method had lower brightness and chroma than the CS group using the general sintering method.

한글판 치료협력 설문지 개발 및 신뢰도 분석 (Korean Cultural Adaptation of Working Alliance Inventory and Its Reliability)

  • 유승훈;하혜경;이해정
    • The Journal of Korean Physical Therapy
    • /
    • 제26권2호
    • /
    • pp.90-96
    • /
    • 2014
  • Purpose: The aim of the study was to develop the Korean version of the Working Alliance Inventory (KWAI) and to assess reproducibility of both its therapist and client forms. Methods: The 12-item WAI was translated into Korean. The translation procedure followed the guidelines proposed by Beaton et al. (2000). Development of KWAI involved its translation, back-translation, and pilot testing of the pre-final version to establish Korean cultural adaptation of the original version of WAI. For test-retest reliability, therapists (N=30) and clients (N=47) completed the questionnaire on two different occasions. The interval between occasions was two to seven days, depending on subject availability. Data were collected from clinicians working in general hospitals and private clinics, and clients who had received treatment within three months. The intra-class correlation (ICC ($_{2.1}$)) was calculated for assessment of the reproducibility of the translated questionnaire. Results: The test-retest ICC ($_{2.1}$) of the client form and the therapist form was 0.92 (95%CI:0.86-0.95) and 0.94 (95%CI:0.89-0.97), respectively. Answers to items 2, 8, and 11 showed a tendency to be omitted due to ambiguity of meaning in Korean. Idiomatic expression was employed rather than word-to-word translation to have clear meaning of those items. Conclusion: The KWAI was successfully translated and adapted for applications to Korean clients and therapists, with a satisfactory level of reliability. Therefore, it can be suggested that the KWAI is useful in providing a reliable assessment of working alliance between therapists and clients.

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

  • Na, Eui-Ri;Aljawad, Hussein;Lee, Kyung-Min;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제49권1호
    • /
    • pp.41-48
    • /
    • 2019
  • Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

Pantograph를 이용한 악관절잡음자의 하악운동에 관한 연구 (A Pantographic Study on the Mandibular Movements in Patients with Temporomandibular Joint Sounds)

  • 이풍호;한경수
    • Journal of Oral Medicine and Pain
    • /
    • 제12권1호
    • /
    • pp.85-93
    • /
    • 1987
  • The author studied on the effect of TMJ sounds to the patterns and ranges of mandibular border movements in horizontal plane with Pantograph (Denar Corp.). For study, 19 patients with TMJ sounds only and 16 students with no TM disorder were selected and classified as experimental group and control group, respectively. The subject performed right lateral movement, left lateral movement, and forward movement. Each movement were performed 3 times and the movement trajectory obtained with mechanical pantograph were observed for accordance of centric relation position, reproducibility and/or restriction of lateral movement paths, deviation of protrusive path in anterior table, restriction of protrusive condylar movement path in posterior horizontal table, presence of Fisher angle in posterior vertical table. And pantographic reproducibility Index (PRI) were obtained with pantronic by the same movement method as in the mechanical pantograph record. The obtained results were as follows : 1. In experimental group, PRI scores in those who show accordance of centric relation position were 14.4, and were 26.53 in those who did not show accordance of centric relation position. However, the PRI scores of the two subgroups show no statistically significant difference in control group. Therefore, in experimental group, the capability of accordance of centric relation position affected largely the PRI scores than in control group. 2. Deviation of protrusive path was opposite to the affected side in experimental group, and was left side in control group. 3. Restriction side of condylar movement in protrusion was ipsilateral to the deviation side in experimental group, but in control group, restriction side was not related to the deviation side. 4. PRI scores in experimental group were 23.2 (moderate dysfunction category), and in control group, were 17.8 (slight dysfunction category). The PRI scores in control group, however, implies that the evaluation of temporomandibular disorders by the PRI scores only may be unreasonable.

  • PDF

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

Relationship between Progressive Changes in Lamina Cribrosa Depth and Deterioration of Visual Field Loss in Glaucomatous Eyes

  • Kim, You Na;Shin, Joong Won;Sung, Kyung Rim
    • Korean Journal of Ophthalmology
    • /
    • 제32권6호
    • /
    • pp.470-477
    • /
    • 2018
  • Purpose: To investigate the relationship between the progression of visual field (VF) loss and changes in lamina cribrosa depth (LCD) as determined by spectral-domain optical coherence tomography (SD-OCT) enhanced depth imaging in patients with primary open angle glaucoma (POAG). Methods: Data from 60 POAG patients (mean follow-up, $3.5{\pm}0.7$ years) were included in this retrospective study. The LCD was measured in the optic disc image using SD-OCT enhanced depth imaging scanning at each visit. Change in the LCD was considered to either 'increase' or 'decrease' when the differences between baseline and the latest two consecutive follow-up visits were greater than the corresponding reproducibility coefficient value ($23.08{\mu}m$, as determined in a preliminary reproducibility study). All participants were divided into three groups: increased LCD (ILCD), decreased LCD (DLCD), and no LCD change (NLCD). The Early Manifest Glaucoma Trial criteria were used to define VF deterioration. Kaplan-Meier survival analysis and Cox's proportional hazard models were performed to explore the relationship between VF progression and LCD change. Results: Of the 60 eyes examined, 35.0% (21 eyes), 28.3% (17 eyes), and 36.7% (22 eyes) were classified as the ILCD, DLCD, and NLCD groups, respectively. Kaplan-Meier survival analysis showed a greater cumulative probability of VF progression in the ILCD group than in the NLCD (p < 0.001) or DLCD groups (p = 0.018). Increased LCD was identified as the only risk factor for VF progression in the Cox proportional hazard models (hazard ratio, 1.008; 95% confidence interval, 1.000 to 1.015; p = 0.047). Conclusions: Increased LCD was associated with a greater possibility of VF progression. The quantitative measurement of LCD changes, determined by SD-OCT, is a potential biomarker for the prediction of VF deterioration in patients with POAG.