• 제목/요약/키워드: Reproducibility of result

검색결과 309건 처리시간 0.03초

Comparison of Reproducibility of Linear Measurements on Digital Models among Intraoral Scanners, Desktop Scanners, and Cone-beam Computed Tomography

  • Jo, Deuk-Won;Kim, Mijoo;Kim, Reuben H.;Yi, Yang-Jin;Lee, Nam-Ki;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose: Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. Materials and Methods: Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics. Bland-Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05). Result: The Bland-Altman plots showed that the bias of each test group was -0.07 mm for CIOS, -0.07 mm for MDS, -0.21 mm for VCT, and -0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). Conclusion: The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.

자기기록식 3일간의 24시간 회상법의 신뢰도 연구 -서울지역 중년 자원자를 대상으로- (Reproducibility of Nutrient Intake Estimated by Three-Day 24-Hour Dietary Recall of Middle-Aged Subjects for 6 Month Intervals)

  • 이미숙;우미경;김성애;오세인;곽충실
    • 대한지역사회영양학회지
    • /
    • 제8권4호
    • /
    • pp.603-609
    • /
    • 2003
  • This study examined the reproducibility of nutrient intakes estimated by the 24-hour recall method in a prospective cohort study (Longitudinal study of aging and health monitoring of Korean elderly) of middle-aged volunteer subjects (42 males and 49 females) in the Seoul area. The three-day 24-hour recall was administered twice at an interval of approximately 6 months. The first data were collected and a corrective procedure was performed by interviewing of the subjects and a trained dietitian. The second data were collected by mail from the subjects without the performance of any corrective procedure. The mean age of the subjects was 53.5 $\pm$ 9.6 for the males and 52.2 $\pm$ 8.9 for the females. The subjects who had above college education were 95% in the case of the males and 60% in the case of the females. The characteristics of the male subjects in this study were that they were highly educated and held professional jobs and were from the middle or upper class. Comparing the first and second 24-hour recall data, the second data showed relatively lower intakes of all nutrients, except vitamin A, vitamin Bi and cholesterol. There was no difference in the nutrients of the first and the second data with respect to vitamin A, vitamin B$_1$ and cholesterol in the males and calcium, iron, sodium, vitamin A, vitamin B$_1$, vitamin B$_2$ and cholesterol in the females. This data may indicate that the 24 hour retail method without a dietitian's help may result in lower reporting of the subject's intakes. The men had a tendency to remember less than the women. Pearson's correlation coefficients with unadjusted nutrient intakes values were ranged from 0.24 to 0.66. When energy intake was adjusted, there was a slight increase (from 0.26 to 0.71). Intra-class correlation coefficients with nutrient-unadjusted values ranged from 0.22 to 0.66, and the energy-adjusted values were ranged from 0.23 to 0.69. The weighted Kappa statistical values ranged from 0.10 to 0.40. On the average,46.3% of the subjects who were found in the lowest quartile of the nutrient intake levels based on the first 24-hour recall, were in the lowest quartile based on the second 24-hour recall. Therefore, there was a low reproducibility between the first and the second 24-hour recall. We should examine the factors influencing low reproducibility. Also, strategies should be developed to maximize the reliability of the assessment, with regard to portion-size training and telephone validation. (Korean J Community Nutrition 8(4) : 603∼609, 2003)

지반물성치 통계분석을 통한 실규모 시험용 제방축조의 재현성에 관한 정량적 평가 (Quantitive Evaluation of Reproducibility of Embankment for Full Scale Test through Statistical Analysis of Physical Properties of Soil)

  • 이희민;문준호;김민진;김영욱
    • 한국지반환경공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.19-23
    • /
    • 2022
  • 하상토를 활용한 제방 축조에 관련된 연구의 실증 및 검증을 위해서는 실규모의 제방 축조 및 시험 연구가 필수인데, 이 중 가장 중요한 인자 중 하나가 시험에 활용되는 다수의 축조된 제방들이 얼마나 동일한 초기 준비 조건으로 축조될 수 있는지, 즉 동일한 시험 초기조건의 다수 재현 가능성에 대한 수치적, 정량적 기준을 먼저 제시하여야 한다. 본 연구에서는 세립분이 함유된 하상토로 시험을 위하여 축조한 복수 제방에 대해 다양한 지반물성치(비중시험, 체가름시험, 액소성한계시험, 다짐시험, 현장밀도시험)를 취득하고, 수집한 데이터의 통계분석을 통해 제방 축조 시 동일 조건의 시험 준비 재현 가능성을 정량적으로 검토할 수 있는 일련의 과정을 수립하여 제시하였다. 과정수립에 대한 검증으로 시험용 제방을 축조하고 지반물성치를 수집하여 통계분석한 결과, 시험용 제방의 동일 조건 축조 재현성에 대한 정량적 평가가 가능함을 확인할 수 있었으며, 이는 제방뿐만 아니라 다양한 실규모 시험에 있어 초기조건의 정량적 동일성을 평가할 수 있는 기초적인 자료가 될 수 있을 것으로 기대된다.

GCM 및 상세화 기법 선정을 고려한 충주댐 유입량 기후변화 영향 평가 (Future Climate Change Impact Assessment of Chungju Dam Inflow Considering Selection of GCMs and Downscaling Technique)

  • 김철겸;박지훈;조재필
    • 한국기후변화학회지
    • /
    • 제9권1호
    • /
    • pp.47-58
    • /
    • 2018
  • In this study, we evaluated the uncertainty in the process of selecting GCM and downscaling method for assessing the impact of climate change, and influence of user-centered climate change information on reproducibility of Chungju Dam inflow was analyzed. First, we selected the top 16 GCMs through the evaluation of spatio-temporal reproducibility of 29 raw GCMs using 30-year average of 10-day precipitation without any bias-correction. The climate extreme indices including annual total precipitation and annual maximum 1-day precipitation were selected as the relevant indices to the dam inflow. The Simple Quantile Mapping (SQM) downscaling method was selected through the evaluation of reproducibility of selected indices and spatial correlation among weather stations. SWAT simulation results for the past 30 years period by considering limitations in weather input showed the satisfactory results with monthly model efficiency of 0.92. The error in average dam inflow according to selection of GCMs and downscaling method showed the bests result when 16 GCMs selected raw GCM analysi were used. It was found that selection of downscaling method rather than selection of GCM is more is important in overall uncertainties. The average inflow for the future period increased in all RCP scenarios as time goes on from near-future to far-future periods. Also, it was predicted that the inflow volume will be higher in the RCP 8.5 scenario than in the RCP 4.5 scenario in all future periods. Maximum daily inflow, which is important for flood control, showed a high changing rate more than twice as much as the average inflow amount. It is also important to understand the seasonal fluctuation of the inflow for the dam management purpose. Both average inflow and maximum inflow showed a tendency to increase mainly in July and August during near-future period while average and maximum inflows increased through the whole period of months in both mid-future and far-future periods.

분광타원해석기를 이용한 자외선 차단제의 평가방법 연구 (Study on the Sun Screen Test Method using Elipsometer)

  • 김준우;이종수;이지혜;정석진
    • 대한화장품학회지
    • /
    • 제37권2호
    • /
    • pp.137-141
    • /
    • 2011
  • 자외선 차단제는 자외선의 흡수 기능을 갖는 유기 계열과 반사 기능을 갖는 무기계로 구분된다. 이들은 SPF지수로 평가되는데 in-vivo 실험은 높은 비용과 시간이 오래 걸리는 단점이 있어 in-vitro 평가가 연구에 많이 이용된다. 하지만 in-vitro 평가로 사용되는 SPF 평가 장치는 재현성이 매우 낮아 값에 대한 신뢰가 매우 어렵다. 또한, UV-vis spectrometer를 이용한 분석은 재현성은 높지만 투과/흡수/반사의 구분된 결과를 구하기 어려운 단점이 있다. 본 연구에서 제시하는 elipsometer는 높은 재현성과 투과/흡수/반사의 구분된 결과, 다양한 각도에서의 평가의 장점이 있어 자외선 차단제 평가에 매우 유용하다. 이를 위해 상업용 자외선 차단제를 다양한 방법으로 평가하여 elipsometer를 이용한 방법의 타당성을 알아보았다.

색각검사법의 재현성 및 반복성평가 (Assessment of Reproducibility and Repeatability for Color Vision Test)

  • 주석희;이은희
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.109-114
    • /
    • 2008
  • 목적: 본 연구는 색각검사법의 반복측정에 따른 결과의 재현성을 평가하기 위해 진행하였다. 방법: 연구 대상자는 선천성 색각이상을 가지고 있지 않은 일개 대학교 안경광학과 학생 30명이었다. 색각이상검사 종류는 한식색각검사와 Hans 15 hue 검사 그리고 Lanthony D 15 hue 검사를 선택하였고, 3명의 검사자를 비교하기 위한 검사에서는 이시하라검사도 추가하였다. 결과: 가성동색표에서는 모두 정상으로 분류되어졌으나, 색분별법에서는 1명이 약한청황색각이상을 보였다. 가성동색표는 3번의 측정 및 검사자간 결과값이 일치하였으며, 색분별법 반복 측정에서 경미한 오류들의 차이가 나타났다. 그러나 실제 색각이상자의 분류에 있어서는 반복측정에 따른 결과값이 차이는 나타나지 않았다. 결론: 각 검사자는 비교적 간단한 색각검사라도 좀더 숙련된 기술로 피험자를 대하는 것이 필요하다. 피험 자 역시 세 번의 측정으로 인한 경험에 의존하여 색각검사를 하기보다는 매 검사는 신중을 기해야 함이 요구되어 진다. 선별검사에서는 두 가지 검사의 병행이 요구되어진다.

  • PDF

방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰 (A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method)

  • 이정은;김호성;류재광;정우영
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.59-66
    • /
    • 2013
  • 최근 방사선 작업종사자의 외부피폭을 감소시키기 위하여 방사성 의약품 자동 분주장치를 사용하는 병원이 증가하는 추세이다. 방사성 의약품 자동 분주장치는 주사기의 피스톤을 잡아당기는 거리(mm)를 조절하여 방사성 의약품을 자동 분주 하도록 설계되어 있어 장비에 장착한 바이알 내 방사성 의약품의 비방사능이 클 때 소량의 원하는 단위 방사능의 방사성 의약품을 분주하기 어렵다. 따라서 본 연구에서는 방사성 의약품 자동 분주장치의 방사능 차폐능력을 평가하고 장비의 분주 재현성을 극대화하는 최적화된 분주방법을 찾고자 세 가지 실험을 진행하였다. 첫 번째 실험은 자동 분주장치의 사용여부에 따른 방사선 작업종사자의 손과 흉부의 피폭 비교 실험이다. 환자에게 $^{18}F-FDG$ 투여 시 30명은 자동 분주로, 30명은 수동으로 분주하여 투여하고 주사과정에서 방사선 작업종사자가 받는 손과 흉부의 피폭선량을 측정하여 비교하였다. 흉부 피폭선량은 독립표본 t-검정 결과, 분주방법에 따라 유의한 차이가 있었고 손의 피폭선량은 자동 분주 시 오른손 검지에서 11.5배 왼손 검지에서 4.8배 낮게 측정되었다. 두 번째 실험은 자동 분주장치의 분주 용량 재현성 평가이다. 생리식염수가 담긴 바이알을 장비에 장착하고 분주하고자 하는 용량을 1부터 15 mm까지 1 mm씩 증가시키면서 5회씩 분주하였을 때 주사기의 무게를 뺀 분주된 생리식염수만의 무게를 마이크로 저울로 측정하여 표준편차와 변동계수를 비교하였다. 그 결과, 표준편차는 분주하고자 하는 용량의 크기가 커짐에 따라 불규칙하게 나타났지만 변동계수는 감소하는 추세를 나타냈다. 또한 작은 크기의 주사기를 사용하였을 때 더 낮은 표준편차와 변동계수를 나타냈다. 세 번째 실험은 자동 분주장치의 분주 방사능 재현성 평가이다. 장비에 장착된 바이알 내 $^{18}F-FDG$의 비방사능이 다를 때 70 kg 환자를 기준으로 kg당 5.17 MBq (0.14 mCi)인 362.6 MBq (9.8 mCi)${\pm}10%$를 분주 후 동일 용량에서 4회 더 분주 하여 dose calibrator에서 방사능을 측정하고 그 표준편차와 변동계수를 비교 분석하였다. 그 결과, 장비에 장착된 바이알 내 $^{18}F-FDG$의 비방사능이 증가할수록 표준편차와 변동계수 모 두 증가하는 추세를 보였으며 작은 크기의 주사기를 사용할 때 더 낮은 편차를 보였다. 또한 바이알 내 $^{18}F-FDG$의 비방사능이 2 mL 주사기를 사용할 때에는 약 1,020 MBq/mL (27.6 mCi/mL) 이하, 5 mL 주사기를 사용할 때에는 약 915 MBq/mL (24.7 mCi/mL) 이하일 때 변동계수를 10% 미만으로 유지시키며 더욱 유용하게 사용할 수 있음을 확인하였다.

  • PDF

전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가 (Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.513-518
    • /
    • 2022
  • 전자선의 정도관리(quality assurance, QA)는 정확한 방사선 치료를 위해 정기적으로 이루어져야한다. 하지만 임상에서 사용되는 QA도구는 X선 위주로 설계되어 있어서 전자선 전용의 QA 선량계가 요구된다. 이에 본 연구에서는 방사선 검출 효율이 뛰어난 브롬화탐륨 물질을 전자선 센서로 활용하여 전자선 검출성능을 측정하고 전자선 전용의 QA 선량계로 적용가능할지를 평가하였다. 평가항목은 재현성, 선형성, 선량률 의존성이며, 선형가속기의 6 MeV, 9 MeV 에너지에서 평가하였다. 재현성 결과, 6 MeV에서는 최대 0.92%, 9 MeV에서는 최대 1.15%의 출력변화를 보여주었다. 선형성 결과평가, 결정계수 R2이 0.9998로 제시되었다. 선량률 의존성 평가 결과, 6 MeV에서는 상대표준편차 0.51%, 9 MeV에서는 상대표준편차 1.07%의 선량률 의존성이 제시되었다. 본 연구에서 제작한 TlBr 센서는 재현성, 선형성, 선량률 의존성의 모든 평가기준을 만족하는 검출성능을 보여준다. 이러한 결과들은 TlBr 선량계가 전자선 전용 QA 선량계로 적용 가능한 것을 의미한다.

형체력에 따른 사출성형기 플렉스링크의 특성 분석 (Characteristics Analysis of Flex Link according to Mold Clamping Force in Injection Molding Machine)

  • 정현석;유중학
    • 한국정밀공학회지
    • /
    • 제31권2호
    • /
    • pp.165-170
    • /
    • 2014
  • Reproducibility of injection molding machines are studied at the study of this time. We applied computer aided engineering program so it could generate clamping force, about 1,500 kN, to the nozzle center part of flex link in tie-bar and at this time, we made sure condition of stress distribution and transformation quantity in flex link. The result of computer aided engineering transformation quantity was confirmed that transformation of top area was 247~257 kN and bottom areas was 273~279 kN and also was confirmed that the stresses are distributed in a range of 57~750 $N/mm^2$ from top to the bottom of the surface. This time we could confirm the condition of transformation quantity and stress distribution by enforcing the previously used structure analysis of flex link. And we utilized the reference data to establish important point of section for non destructive test overhaul.

Accurate Quantification of Saccharin Using Isotope Dilution Liquid Chromatography Mass Spectrometry (ID-LC/MS)

  • Lee, Yun-Jung;Kim, Byung-Joo;Kim, Jeong-Kwon;Ahn, Seong-Hee
    • Mass Spectrometry Letters
    • /
    • 제2권2호
    • /
    • pp.37-40
    • /
    • 2011
  • Saccharin is a commonly used artificial sweetener in foodstuffs. However, for its carcinogenic dispute, it has been regulated by government bodies. In this study, isotope dilution mass spectrometry (ID-MS) was introduced for the accurate quantification of saccharin. To employ ID-LC/MS, we obtained its isotope analogue, $^{13}C_1$-sodium saccharin, by customized synthesis. Samples were spiked with $^{13}C_1$-sodium saccharin and analyzed with LC/MS in negative mode. Chromatographic conditions were optimized for the adequate chromatographic retention and separation of saccharin with a $C_{18}$ column. MS was operated with electrospray ionization by the selected ion monitoring (SIM) mode of $[M-H]^-$ for saccharin (m/z 182) and $[M-Na]^-$ for its isotope analogue (m/z 183). To validate the ID-LC/MS method for accurate measurement, we prepared a batch of a candidate material by sortifying quasi-tea-drinks with saccharin and analyzed samples gravimetrically fortified in various levels of concentration. The repeatability and reproducibility of this method was tested by analyzing the reference material. Result show that ID-LC/MS is a reliable method for the quantitative analysis of saccharin.