• Title/Summary/Keyword: Reproducibility(kappa value)

Search Result 7, Processing Time 0.023 seconds

Agreement of two ELISAs for Mycobacterium avium subspecies paratuberculosis in cattle in Korea

  • Lee, Kyung Woo;Jung, Byeong Yeal;Hwang, In Yeong;Lee, Su Hwa;Kim, Ji Yeon;Kim, Young Hoan;Lee, Seong Hyo;Moon, Oun Kyoung;Lee, O Soo
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.2
    • /
    • pp.121-125
    • /
    • 2009
  • Paratuberculosis caused by Mycobacterium avium subspecies paratuberculosis (Mpt) is a chronic infectious enteric disease with deleterious impact on the performance in ruminants. In Korea, ELISA has been introduced to detect antibodies to Mpt in individual cattle. However, comparison study with ELISA has not been studied until now. In total, a panel of 899 serum samples obtained from dairy cattle was analyzed with two commercial ELISAs for Mpt to assess the performance. Two ELISAs employed in this study were both licensed worldwide. Two ELISAs applied onto same serum samples showed the moderate agreement (kappa value = 0.60). There was non-significant McNemar test (p = 0.0614) between two ELISA results indicating that each proportion detected by two kits did not differ. In addition, the percent agreement between two ELISA results was turned out to be 96.8% which interpreted excellent reproducibility. It was shown from this study that two ELISAs revealed moderate kappa agreement performance. The implication raised is that when ELISAs as diagnostics are used to detect Mpt in individual cattle, positive reaction by either ELISA should be interpreted as serologically Mpt positive due to presumed low sensitivity of ELISAs and their test agreement being less than 100%.

DETECTION OF OCCLUSAL CARIES USING LASER FLUORESCENCE (레이저 형광법의 교합면 우식증 탐지 효과)

  • Kim, Chang-Gi;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.600-606
    • /
    • 2002
  • The purpose of this study was to evaluate the diagnostic validity of an incipient occlusal caries using argon laser fluorescence. Extracted human premolars and molars with enamel carious lesion of occlusal surface were assessed using visual examination, visual examination with probing, argon laser fluorescence and histologic depth of carious lesion. The results in each of all the three detection methods were compared to the assessment of histologic depth of carious lesion using polarized microscope. The results from the present study can be summarized as follows; 1. There was highly correlation between the histologic depth of occlusal caries and all three detection methods(P<0.01). 2. The reproducibility(kappa value) of the visual examination, visual examination with probing and argon laser fluorescence between the histologic depth of occlusal caries was 0.189, 0.128, 0.472. The highest correlation was seen between detection of occlusal caries by argon laser fluorescence and histologic scores by polarized microscope. The results from this study indicated that argon laser fluorescence considered to be accurate and reliable method in detecting occlusal caries.

  • PDF

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Validity of Self-Reported Height, Weight, and Body Mass Index of the Korea Youth Risk Behavior Web-Based Survey Questionnaire

  • Bae, Ji-Suk;Joung, Hyo-Jee;Kim, Jong-Yeon;Kwon, Kyoung-Nam;Kim, Yoon-Jung;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.5
    • /
    • pp.396-402
    • /
    • 2010
  • Objectives: Self-reported anthropometric values, such as height and weight, are used to calculate body mass index (BMI) and assess the prevalence of obesity among adolescents. The aim of this study was to evaluate the validity of selfreported height, weight, and BMI of the Korea Youth Risk Behavior Web-based Survey questionnaire. Methods: A convenience sample of 137 middle school students and 242 high school students completed a selfadministered questionnaire in 2008. Body height and weight were directly measured after self-reported values were obtained from the questionnaire survey. Sensitivity, specificity, and kappa statistics were computed in order to evaluate the validity of the prevalence of obesity (BMI $\geq$ 95th percentile or $\geq$ $25;kg/$m^2$) based on self-reported data. Results: Self-reported weight and BMI tended to be underestimated. Self-reported height tended to be overestimated among middle school females and high school males. Obese adolescents tended to underestimate their weight and BMI and overestimate their height more than non-obese adolescents. The prevalence estimate of obesity based on selfreported data (10.6%) was lower than that based on directly measured data (15.3%). The estimated sensitivity of obesity based on self-reported data was 69.0% and the specificity was 100.0%. The value of kappa was 0.79 (95% confidence interval, 0.70 - 0.88). Conclusions: This study demonstrated that self-reported height and weight may lead to the underestimation of BMI and consequently the prevalence of obesity. These biases should be taken into account when self-reported data are used for monitoring the prevalence and trends of obesity among adolescents nationwide.

Interobserver and Intraobserver Reliability of Sub-Axial Injury Classification and Severity Scale between Radiologist, Resident and Spine Surgeon

  • Lee, Woo Jin;Yoon, Seung Hwan;Kim, Yeo Ju;Kim, Ji Yong;Park, Hyung Chun;Park, Chon Oon
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.200-203
    • /
    • 2012
  • Objective : The sub-axial injury classification (SLIC) and severity scale was developed to decide whether to operate the cervical injured patient or not, but the reliability of SLIC and severity scale among the different physicians was not well known. Therefore, we evaluated the reliability of SLIC among a spine surgeon, a resident of neurosurgery and a neuro-radiologist. Methods : In retrograde review in single hospital from 2002 to 2009 years, 75 cases of sub-axial spine injured patients underwent operation. Each case was blindly reviewed for the SLIC and severity scale by 3 different observers by two times with 4 weeks interval with randomly allocated. The compared axis was the injury morphology score, the disco-ligamentous complex score, the neurological status score and total SLIC score; the neurological status score was derived from the review of medical record. The kappa value was used for the statistical analysis. Results : Interobserver agreement of SLIC and severity scale was substantial agreement in the score of injury morphology [intraclass correlation (ICC)=0.603] and total SLIC and severity sacle (ICC value=0.775), but was fair agreement in the disco-ligamentous complex score (ICC value= 0.304). Intraobserver agreements were almost perfect agreement in whole scales with ICC of 0.974 in a spine surgeon, 0.948 in a resident of neurosurgery, and 0.963 in a neuro-radiologist. Conclusion : The SLIC and severity scale is comprehensive and easily applicable tool in spine injured patient. Moreover, it is very useful tool to communicate among spine surgeons, residents of neurosurgery and neuro-radiologists with sufficient reproducibility.

DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증 탐지효과)

  • Mo, Kyung-Hee;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.323-330
    • /
    • 2004
  • The purpose of this study was to evaluate the diagnostic validity of early proximal caries lesions using laser fluorescence and whether the detection could be enhanced using a fluorescent dye. Direct visual examination and bitewing radiograph were used for comparison. The subjects of this study were 30 children of $3{\sim}9$ years old. Laser fluorescence and dye-enhanced laser fluorescence(mixed wavelength of 488 and 514 nm) were used and viewed through glasses(excluding wavelength<520 nm). For dye-enhanced laser fluorescence a 0.075% sodium fluorescein dye was applied before examination. Proximal caries lesion of each subject was assessed using visual examination, bitewing radiograph, laser fluorescence, and dye-enhanced laser fluorescence. The results in the three detection methods were compared to the assessment of bitewing radiograph. The results from the present study can be summarized as follows: 1. There was highly correlation(r=0.725-0.911) between the bitewing radiograph and all three detection methods(p<0.05) 2. The reproducibility(kappa value) of the visual examination, laser fluorescence and dye-enhanced laser fluorescence comparing with bitewing radiograph of proximal caries was 0.451, 0.683, 0.772, respectively. There was highest correlation between dye-enhanced laser fluorescence and bitewing radiograph for detection of proximal caries. The results from this study indicated that the dye-enhanced laser fluorescence considered to be accurate and reliable method in detecting proximal caries.

  • PDF

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.