• Title/Summary/Keyword: Replica

Search Result 511, Processing Time 0.056 seconds

Comparison of Sound Spectrums of Pyeonjong Remains at the King Sejong Memorial Museum and Pyeonjong Replica (세종대왕기념관의 유물 편종과 현대 편종의 음향 스펙트럼 비교)

  • Yoo, June-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.222-228
    • /
    • 2009
  • This study compared the sound spectrums of pyeonjong remains and pyeonjong replica to investigate tuning ways of bells. pyeonjong remains, exhibited at King Sejong Memorial Museum and pyeonjong replica, played at the National Center for Korean Traditional Performance Arts were analyzed. To get mode frequencies and mode shapes, pyeonjong replicas' sound spectrums were analyzed and modal analyses by TV holography were performed. Also pyeonjong remains' sound spectrum were analyzed. Nominal frequencies on the pyeonjong replica and remains showed differences in a range between 9.8 cent and 203 cent. Two facts were inferred as causes of the differences, the tuning conditions of pyeonjong remains were not good and C4 in western tempered scale was preferred as the sound standard of Kukak, whangjong. Relative ratio of higher mode frequencies to the nominal frequencies were calculated to figure out tonal differences between two pyeonjongs. The differences in relative ratio of higher mode frequencies except (3,0)a and (3,0)b modes were significants as well as beyond the just noticeable difference. These results implied that the tonal differences between two pyeonjongs could exist. More pyeonjong remains are needed to be investigated to confirm this result in addition to the analyses of alloy components and bell structure of pyeonjong remains and replica.

Phase Transition of Confined Gold Nanoparticles: Replica Exchange Molecular Dynamics Study

  • Kim, Hyun-Sik;Li, Feng-Yin;Jang, Soon-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.929-932
    • /
    • 2012
  • The classical molecular dynamics simulation was used to study the phase transition of gold nanoparticles under confinement using Sutton-Chen (SC) potential. Metal gold nanoparticles with different number of atoms are subject to replica exchange molecular dynamics simulation for this purpose. The simulation showing the solidto-liquid melting temperature largely remains unaffected by confinement, while the confinement induces characteristic pre-melting at very low temperature depending on atom number in nanoparticles.

경수로 압력용기 모의실험 PCA-REPLICA 차폐 벤치마크 해석

  • 길충섭;김정도;황원국
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.163-168
    • /
    • 1998
  • 경수로 압력용기의 취화는 주로 고속 중성자에 기인한다. 경수로 압력용기를 모의한 PCA-REPLICA실험을 해석하여 원자력 시설의 구조재로 쓰이는 철의 핵자료 검증과 MATXS/TRANSX/DANTSYS 계산체제의 유용성을 확인하고자 하였다. 라이브러리는 JEF-2.2를 이용한 KAFAX-F22가 기본 자료로 이용되었고, 이밖에 ENDF/B-Vl.1과 JENDI.-3.2의 철 핵자료도 비교 검증하였다. 계산결과는 실험오차 등을 고려하면 측정치와 근접하는 경향을 보였고, 앞으로 개발될 차폐해석용 라이브러리 검증에 유용한 자료가 될 수 있겠다.

  • PDF

Fabrication of high ordered nano-sphere array on curved substrate by nanoimprint lithography

  • Hong, Seong-Hun;Bae, Byeong-Ju;Lee, Heon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.127-127
    • /
    • 2008
  • The replica of highly ordered nano-sphere array patterns were fabricated using hot embossing method. The polymer replica was coated with silcon dioxide layer and self-assembled monolayer. Using UV nanoimprint lithography with the template, highly ordered nano-sphere array patterns were clearly fabricated on curved substrate.

  • PDF

A New Material for Rapid and Easy Method of Plant Surface Imprinting

  • Bhat, R.B.;Etejere, E.O.
    • Journal of Plant Biology
    • /
    • v.28 no.4
    • /
    • pp.329-332
    • /
    • 1985
  • A simple new device for obtaining very clear epidermal imprints for light microscopic studies is discussed. This new device is developed from“Britfix”(polystyrene cement) which is non-toxic to the plant organs. It involves direct application of the material on the desired surface of the plant organ to obtain thin, transparent replica. From the present investigation“Britfix”is found to be useful for the study of epidermal anatomy, morphology and physiology. Epidermal imprints can be mounted on the microscope slide without a mounting medium. Permanent slide of these imprints can be kept for any desired period without any deterioration of the replica.

  • PDF

Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis

  • Park, Jin-Young;Bae, So-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.159-169
    • /
    • 2017
  • PURPOSE. The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS. Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (${\alpha}=.05$). RESULTS. Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION. All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

An Efficient Peer-to-Peer Based Replication Strategy for Data Grid (데이터 그리드를 위한 효율적인 Peer-to-Peer 기반 복제 정책)

  • Oh, Sang-Won;Lee, Won-Joo;Jeon, Chang-Ho
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.2
    • /
    • pp.10-17
    • /
    • 2008
  • In this paper, we propose an efficient data replication strategy based on Peer-to-Peer which improves the performance of Data Grid system. The key idea of this replication strategy is to add the Peer-to-Peer concept for reducing data transmission restriction caused by hierarchical topology. And, it makes the nodes can store data replica to set a critical section at the storage of client level nodes. Therefore, it is possible to transmit the data replica between client level nodes and from client level nodes to upper data replication server. It is more effective to transmit data replica between client level nodes than transmitting data replica 1mm data server or data replication server with respect to minimize the transmission time. This results in improving the performance of Data Grid system. Through simulation, we show that the proposed data replication strategy based on Peer-to-Peer improves the performance of entire Data Grid environment compared to previous strategies.

Quorum Consensus Method based on Ghost using Simplified Metadata (단순화된 메타데이타를 이용한 고스트 기반 정족수 동의 기법의 개선)

  • Cho, Song-Yean;Kim, Tai-Yun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.1
    • /
    • pp.34-43
    • /
    • 2000
  • Replicated data that is used for fault tolerant distributed system requires replica control protocol to maintain data consistency. The one of replica control protocols is quorum consensus method which accesses replicated data by getting majority approval. If site failure or communication link failure occurs and any one can't get quorum consensus, it degrades the availability of data managed by quorum consensus protocol. So it needs for ghost to replace the failed site. Because ghost is not full replica but process which has state information using meta data, it is important to simplify meta data. In order to maintain availability and simplify meta data, we propose a method to use cohort set as ghost's meta data. The proposed method makes it possible to organize meta data in 2N+logN bits and to have higher availability than quorum consensus only with cohort set and dynamic linear voting protocol. Using Markov model we calculate proposed method's availability to analyze availability and compare it with existing protocols.

  • PDF